Literature DB >> 17916377

Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle.

Lisandro M Sakata1, Raghavan Lavanya, David S Friedman, Han T Aung, Hong Gao, Rajesh S Kumar, Paul J Foster, Tin Aung.   

Abstract

PURPOSE: To compare the performance of gonioscopy and anterior segment (AS) optical coherence tomography (OCT) in detecting angle closure in the different quadrants of the anterior chamber angle (ACA).
DESIGN: Cross-sectional observational study. PARTICIPANTS: Five hundred two consecutive subjects more than 50 years of age with no previous ophthalmic problems recruited from a community clinic in Singapore.
METHODS: All subjects underwent gonioscopy and AS OCT imaging in the dark. Using gonioscopy, the ACA was graded using the Scheie system by a single examiner masked to AS OCT findings. MAIN OUTCOME MEASURES: The ACA in a particular quadrant was classified as closed if the posterior trabecular meshwork could not be seen on gonioscopy. A closed ACA on AS OCT imaging was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur.
RESULTS: After excluding eyes with poor image quality, a total of 423 right eyes were included in the analysis. A closed angle in at least 1 quadrant was observed in 59% of the eyes by AS OCT and in 33% of the eyes by gonioscopy (P<0.001), with fair agreement between the two methods (kappa = 0.40). The frequency of closed angles by AS OCT and gonioscopy were 48% versus 29% superiorly, 43% versus 22% inferiorly, 18% versus 14% nasally, and 12% versus 20% temporally, respectively. Of the 119 of 1692 quadrants that were closed on gonioscopy but open on AS OCT, a steep iris profile was present in 61 (51%) of 119 quadrants on AS OCT, and of the 276 of 1692 quadrants that were open on gonioscopy but closed on AS OCT, 196 (71%) of 276 quadrants showed short iridoangle contact on AS OCT.
CONCLUSIONS: The highest rates of closed angles on gonioscopy and AS OCT images were observed in the superior quadrant. Anterior segment OCT tended to detect more closed ACAs than gonioscopy, particularly in the superior and inferior quadrants. Variations in the iris profile and level of iridoangle contact also may explain some of the differences seen between gonioscopy and AS OCT.

Entities:  

Mesh:

Year:  2007        PMID: 17916377     DOI: 10.1016/j.ophtha.2007.06.030

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  56 in total

1.  Differences in baseline dark and the dark-to-light changes in anterior chamber angle parameters in whites and ethnic Chinese.

Authors:  Dandan Wang; Cynthia Chiu; Mingguang He; Lingling Wu; Andrew Kao; Shan Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-12-09       Impact factor: 4.799

2.  Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study.

Authors:  Kyoung Sub Lee; Kyung Rim Sung; Sung Yong Kang; Jung Woo Cho; Dong Yoon Kim; Michael S Kook
Journal:  Jpn J Ophthalmol       Date:  2011-05-11       Impact factor: 2.447

3.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

4.  Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography.

Authors:  Elton Lik Tong Tay; Vernon Khet Yau Yong; Boon Ang Lim; Stelson Sia; Elizabeth Poh Ying Wong; Leonard Wei Leon Yip
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

Review 5.  High-Resolution Optical Coherence Tomography as an Adjunctive Tool in the Diagnosis of Corneal and Conjunctival Pathology.

Authors:  Afshan A Nanji; Fouad E Sayyad; Anat Galor; Sander Dubovy; Carol L Karp
Journal:  Ocul Surf       Date:  2015-04-06       Impact factor: 5.033

6.  Five-year incidence of angle closure among glaucoma health examination participants.

Authors:  Kenji Kashiwagi; Tatsuya Chiba; Fumihiko Mabuchi; Toshie Furuya; Shigeo Tsukahara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-25       Impact factor: 3.117

7.  Comparison of dynamic changes in anterior ocular structures examined with anterior segment optical coherence tomography in a cohort of various origins.

Authors:  Fiona E Seager; Joan L Jefferys; Harry A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-19       Impact factor: 4.799

8.  Comparison of slit lamp-adapted optical coherence tomography features of fellow eyes of acute primary angle closure and eyes with open angle glaucoma.

Authors:  Argyrios Tzamalis; Duy-Thoai Pham; Christopher Wirbelauer
Journal:  Jpn J Ophthalmol       Date:  2014-02-06       Impact factor: 2.447

9.  Sectoral variations of iridocorneal angle width and iris volume in Chinese Singaporeans: a swept-source optical coherence tomography study.

Authors:  Tin A Tun; Mani Baskaran; Shamira A Perera; Anita S Chan; Ching-Yu Cheng; Hla M Htoon; Lisandro M Sakata; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-30       Impact factor: 3.117

10.  Non-contact tests for identifying people at risk of primary angle closure glaucoma.

Authors:  Anish Jindal; Irene Ctori; Gianni Virgili; Ersilia Lucenteforte; John G Lawrenson
Journal:  Cochrane Database Syst Rev       Date:  2020-05-28