Literature DB >> 18408181

Anterior chamber angle measurement with anterior segment optical coherence tomography: a comparison between slit lamp OCT and Visante OCT.

Christopher Kai-shun Leung1, Haitao Li, Robert Neal Weinreb, Jing Liu, Carol Yim Lui Cheung, Ricky Yiu Kwong Lai, Chi Pui Pang, Dennis Shun Chiu Lam.   

Abstract

PURPOSE: To compare anterior chamber angle measurements obtained from two anterior segment optical coherence tomography (OCT) instruments and to evaluate their agreements and interobserver reproducibility.
METHODS: Forty-nine eyes from 49 healthy normal subjects were studied. The anterior chamber angle was imaged with the Visante anterior segment OCT (Carl Zeiss Meditec, Dublin, CA) and the slit lamp OCT (SLOCT, Heidelberg Engineering, GmbH, Dossenheim, Germany) on one randomly selected eye in each subject and measured by two independent observers. The angle-opening distance (AOD 500), the trabecular-iris angle (TIA 500), and the trabecular-iris space area (TISA 500) at the nasal and temporal angles were measured. The agreements between SLOCT and Visante OCT measurements and the interobserver reproducibility were evaluated.
RESULTS: The mean nasal/temporal anterior chamber angles measured by Visante OCT and SLOCT were 527 +/- 249/572 +/- 275 microm (AOD), 0.180 +/- 0.091/0.193 +/- 0.102 mm(2) (TISA), and 38.1 +/- 12.3/39.6 +/- 13.2 degrees (TIA); and 534 +/- 234/628 +/- 254 microm (AOD), 0.191 +/- 0.089/0.217 +/- 0.093 mm(2)(TISA), and 37.8 +/- 10.1/40.6 +/- 10.7 degrees (TIA), respectively. No significant difference was found between Visante OCT and SLOCT measurements except the temporal TISA (P = 0.034). The interobserver coefficient of variation ranged between 4.4% and 7.8% for Visante OCT and 4.9% and 7.0% for SLOCT. The spans of 95% limits of agreement of the nasal/temporal angle measurements between Visante OCT and SLOCT were 437/531 mm(2), 0.174/0.186 mm(2), and 25.3/28.0 degrees for AOD, TISA, and TIA, respectively.
CONCLUSIONS: Although Visante OCT and SLOCT demonstrate high interobserver reproducibility for anterior chamber angle measurements, their agreement was poor.

Entities:  

Mesh:

Year:  2008        PMID: 18408181     DOI: 10.1167/iovs.07-1477

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  43 in total

1.  Scanning beyond the limits of standard OCT with a Fourier domain optical coherence tomography integrated into a slit lamp: the SL SCAN-1.

Authors:  M Stehouwer; F D Verbraak; H R de Vries; T G van Leeuwen
Journal:  Eye (Lond)       Date:  2010-11-12       Impact factor: 3.775

2.  Comparison of the anterior ocular segment measurements using swept-source optical coherent tomography and a scanning peripheral anterior chamber depth analyzer.

Authors:  Toshie Furuya; Fumihiko Mabuchi; Tatsuya Chiba; Satoshi Kogure; Shigeo Tsukahara; Kenji Kashiwagi
Journal:  Jpn J Ophthalmol       Date:  2011-08-10       Impact factor: 2.447

3.  The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation.

Authors:  Burcu Kemer Atik; Cigdem Altan; Alper Agca; Asli Kirmaci; Yusuf Yildirim; Selim Genc; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2019-11-23       Impact factor: 2.031

4.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

5.  Analysis of iris structure and iridocorneal angle parameters with anterior segment optical coherence tomography in Fuchs' uveitis syndrome.

Authors:  Berna Basarir; Cigdem Altan; Eylem Yaman Pinarci; Ugur Celik; Banu Satana; Ahmet Demirok
Journal:  Int Ophthalmol       Date:  2013-01-01       Impact factor: 2.031

6.  Assessment of trabecular meshwork width using swept source optical coherence tomography.

Authors:  Tin A Tun; Mani Baskaran; Ce Zheng; Lisandro M Sakata; Shamira A Perera; Anita S Chan; David S Friedman; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-23       Impact factor: 3.117

7.  Comparison of slit lamp-adapted optical coherence tomography features of fellow eyes of acute primary angle closure and eyes with open angle glaucoma.

Authors:  Argyrios Tzamalis; Duy-Thoai Pham; Christopher Wirbelauer
Journal:  Jpn J Ophthalmol       Date:  2014-02-06       Impact factor: 2.447

8.  Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.

Authors:  Peng Li; Murray Johnstone; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2014-04       Impact factor: 3.170

9.  Two-photon imaging of the mouse eye.

Authors:  Andrew W Johnson; David A Ammar; Malik Y Kahook
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-09       Impact factor: 4.799

10.  Two-photon imaging of the trabecular meshwork.

Authors:  David A Ammar; Tim C Lei; Emily A Gibson; Malik Y Kahook
Journal:  Mol Vis       Date:  2010-05-29       Impact factor: 2.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.