Literature DB >> 25938053

Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography.

Elton Lik Tong Tay1, Vernon Khet Yau Yong2, Boon Ang Lim2, Stelson Sia3, Elizabeth Poh Ying Wong2, Leonard Wei Leon Yip2.   

Abstract

AIM: To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography (AS-OCT), as well as gonioscopy and spectral domain OCT (SD-OCT). A secondary objective was to quantify inter-observer agreements of AS-OCT and SD-OCT assessments.
METHODS: Seventeen consecutive subjects (33 eyes) were recruited from the study hospital's Glaucoma clinic. Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other's analyses of OCT images.
RESULTS: Totally 84.8% and 45.5% of scleral spurs were visualized in AS-OCT and SD-OCT images respectively (P<0.01). The agreement for angle closure between AS-OCT and gonioscopy was fair at k=0.31 (95% confidence interval, CI: 0.03-0.59) and k=0.35 (95% CI: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k=0.21 (95% CI: 0.07-0.49) and slight at k=0.17 (95% CI: 0.08-0.42) for reader 1 and 2 respectively. The inter-reader agreement for angle closure in AS-OCT images was moderate at 0.51 (95% CI: 0.13-0.88). The inter-reader agreement for angle closure in SD-OCT images was slight at 0.18 (95% CI: 0.08-0.45).
CONCLUSION: Significant proportion of scleral spurs were not visualised with SD-OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively.

Entities:  

Keywords:  angle closure assessment; anterior segment imaging; spectral domain imaging

Year:  2015        PMID: 25938053      PMCID: PMC4413570          DOI: 10.3980/j.issn.2222-3959.2015.02.23

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  21 in total

1.  Real-time optical coherence tomography of the anterior segment at 1310 nm.

Authors:  S Radhakrishnan; A M Rollins; J E Roth; S Yazdanfar; V Westphal; D S Bardenstein; J A Izatt
Journal:  Arch Ophthalmol       Date:  2001-08

2.  Width and pigmentation of the angle of the anterior chamber; a system of grading by gonioscopy.

Authors:  H G SCHEIE
Journal:  AMA Arch Ophthalmol       Date:  1957-10

3.  Ophthalmic imaging by spectral optical coherence tomography.

Authors:  Maciej Wojtkowski; Tomasz Bajraszewski; Iwona Gorczyńska; Piotr Targowski; Andrzej Kowalczyk; Wojciech Wasilewski; Czesław Radzewicz
Journal:  Am J Ophthalmol       Date:  2004-09       Impact factor: 5.258

4.  Clinical use of ultrasound biomicroscopy.

Authors:  C J Pavlin; K Harasiewicz; M D Sherar; F S Foster
Journal:  Ophthalmology       Date:  1991-03       Impact factor: 12.079

5.  Comparison of the scanning peripheral anterior chamber depth analyzer and the modified van Herick grading system in the assessment of angle closure.

Authors:  Mani Baskaran; Francis T S Oen; Yiong-Huak Chan; Sek-Tien Hoh; Ching-Lin Ho; Kenji Kashiwagi; Paul J Foster; Tin Aung
Journal:  Ophthalmology       Date:  2006-11-30       Impact factor: 12.079

6.  Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle.

Authors:  Lisandro M Sakata; Raghavan Lavanya; David S Friedman; Han T Aung; Hong Gao; Rajesh S Kumar; Paul J Foster; Tin Aung
Journal:  Ophthalmology       Date:  2007-10-04       Impact factor: 12.079

7.  Assessment of the scleral spur in anterior segment optical coherence tomography images.

Authors:  Lisandro M Sakata; Raghavan Lavanya; David S Friedman; Han T Aung; Steve K Seah; Paul J Foster; Tin Aung
Journal:  Arch Ophthalmol       Date:  2008-02

8.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

9.  Determinants of lens vault and association with narrow angles in patients from Singapore.

Authors:  Gavin S Tan; Mingguang He; Wanting Zhao; Lisandro M Sakata; Jialiang Li; Monisha E Nongpiur; Raghavan Lavanya; David S Friedman; Tin Aung
Journal:  Am J Ophthalmol       Date:  2012-04-01       Impact factor: 5.258

Review 10.  The epidemiology of primary angle closure and associated glaucomatous optic neuropathy.

Authors:  Paul J Foster
Journal:  Semin Ophthalmol       Date:  2002-06       Impact factor: 1.975

View more
  2 in total

1.  Non-contact tests for identifying people at risk of primary angle closure glaucoma.

Authors:  Anish Jindal; Irene Ctori; Gianni Virgili; Ersilia Lucenteforte; John G Lawrenson
Journal:  Cochrane Database Syst Rev       Date:  2020-05-28

2.  Agreement between Gonioscopic Examination and Swept Source Fourier Domain Anterior Segment Optical Coherence Tomography Imaging.

Authors:  Mohammed Rigi; Nicholas P Bell; David A Lee; Laura A Baker; Alice Z Chuang; Donna Nguyen; Vandana R Minnal; Robert M Feldman; Lauren S Blieden
Journal:  J Ophthalmol       Date:  2016-11-20       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.