Literature DB >> 21181171

Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Yoshitaka Muraoka1, Shinjo Sonoda, Yuki Tsuda, Seiya Tanaka, Masahiro Okazaki, Yutaka Otsuji.   

Abstract

Drug-eluting stent (DES) expansion characteristics after aggressive high-pressure post-dilation using a non-compliant (NC) balloon have not been fully investigated. We evaluated 58 patients with native coronary lesions treated with DESs [24 paclitaxel eluting stents (PES) and 34 sirolimus-eluting stents (SES)]. After post-dilation (12-14 atm) using a stent-mounted semi-compliant balloon to reduce stent edge injury, adjuvant high-pressure post-dilation using NC balloon was performed within the stents. Stent size, stent length, and NC balloon size were selected based on preinterventional intravascular ultrasound (IVUS) assessment. Stent underexpansion was defined according to criteria of the Multicenter Ultrasound Stenting in Coronaries (MUSIC) study as a minimal stent cross-sectional area <90% of the average reference lumen area. Resultant endpoint was to obtain optimal stent expansion. Serial changes of stent expansion and stent symmetry were calculated in each group. After stent-mounted semi-compliant balloon post-dilation, both stents could not achieve adequate percent stent expansion (PES 73 ± 18% vs. SES 67 ± 9%, p = 0.38). After high-pressure post-dilation using an NC balloon, percent stent expansion was 97 ± 14% in PES and 91 ± 13% in SES, respectively (p = 0.25). Axial stent symmetry indices also significantly improved in both groups. Although radial stent symmetry indices improved significantly in PES group, those in the SES group had no significant changes. Finally, frequency of stent underexpansion significantly reduced, 87-20% in PES and 92-15% in SES, respectively (p = 0.01) without any significant stent edge injury. DES expansion improved safely after adjuvant high-pressure post-dilation using an NC balloon under IVUS guidance.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21181171     DOI: 10.1007/s00380-010-0094-0

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  19 in total

1.  Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study.

Authors:  Kenichi Fujii; Stéphane G Carlier; Gary S Mintz; Yi-ming Yang; Issam Moussa; Giora Weisz; George Dangas; Roxana Mehran; Alexandra J Lansky; Edward M Kreps; Michael Collins; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2005-04-05       Impact factor: 24.094

Review 2.  Adjunctive balloon postdilatation after stent deployment: is it still necessary with drug-eluting stents?

Authors:  Bruce R Brodie
Journal:  J Interv Cardiol       Date:  2006-02       Impact factor: 2.279

3.  Impact of a prolonged delivery inflation time for optimal drug-eluting stent expansion.

Authors:  Tomohiro Kawasaki; Hisashi Koga; Takeshi Serikawa; Yoshiya Orita; Shinsuke Ikeda; Takahiro Mito; Yoshitaka Gotou; Yoshiaki Shintani; Atsushi Tanaka; Hidenori Tanaka; Takaya Fukuyama; Nobuhiko Koga
Journal:  Catheter Cardiovasc Interv       Date:  2009-02-01       Impact factor: 2.692

4.  Comparison of paclitaxel-eluting stent and sirolimus-eluting stent expansion at incremental delivery pressures.

Authors:  Aamir Javaid; William W Chu; Edouard Cheneau; Leonardo C Clavijo; Lowell F Satler; Kenneth M Kent; Neil J Weissman; Augusto D Pichard; Ron Waksman
Journal:  Cardiovasc Revasc Med       Date:  2006 Oct-Dec

5.  Intravascular ultrasound assessment of drug-eluting stent expansion.

Authors:  Jose de Ribamar Costa; Gary S Mintz; Stéphane G Carlier; Kenichi Fujii; Koichi Sano; Masashi Kimura; Kaoru Tanaka; Ricardo A Costa; Joanna Lui; Yingbo Na; Celia Castellanos; Sinan Biro; Issam Moussa; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  Am Heart J       Date:  2007-02       Impact factor: 4.749

6.  A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.

Authors:  Gregg W Stone; Stephen G Ellis; David A Cox; James Hermiller; Charles O'Shaughnessy; James Tift Mann; Mark Turco; Ronald Caputo; Patrick Bergin; Joel Greenberg; Jeffrey J Popma; Mary E Russell
Journal:  N Engl J Med       Date:  2004-01-15       Impact factor: 91.245

7.  Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial.

Authors:  Shinjo Sonoda; Yoshihiro Morino; Junya Ako; Mitsuyasu Terashima; Ali H M Hassan; Heidi N Bonneau; Martin B Leon; Jeffrey W Moses; Paul G Yock; Yasuhiro Honda; Richard E Kuntz; Peter J Fitzgerald
Journal:  J Am Coll Cardiol       Date:  2004-06-02       Impact factor: 24.094

8.  A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.

Authors:  Marie-Claude Morice; Patrick W Serruys; J Eduardo Sousa; Jean Fajadet; Ernesto Ban Hayashi; Marco Perin; Antonio Colombo; G Schuler; Paul Barragan; Giulio Guagliumi; Ferenc Molnàr; Robert Falotico
Journal:  N Engl J Med       Date:  2002-06-06       Impact factor: 91.245

9.  Predictors of subacute stent thrombosis: results of a systematic intravascular ultrasound study.

Authors:  Edouard Cheneau; Laurent Leborgne; Gary S Mintz; Jun-ichi Kotani; Augusto D Pichard; Lowell F Satler; Daniel Canos; Marco Castagna; Neil J Weissman; Ron Waksman
Journal:  Circulation       Date:  2003-06-23       Impact factor: 29.690

10.  The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents.

Authors:  Probal Roy; Daniel H Steinberg; Steven J Sushinsky; Teruo Okabe; Tina L Pinto Slottow; Kimberly Kaneshige; Zhenyi Xue; Lowell F Satler; Kenneth M Kent; William O Suddath; Augusto D Pichard; Neil J Weissman; Joseph Lindsay; Ron Waksman
Journal:  Eur Heart J       Date:  2008-06-11       Impact factor: 29.983

View more
  8 in total

1.  Assessment of optimum stent deployment by stent boost imaging: comparison with intravascular ultrasound.

Authors:  Nobuhiro Tanaka; Nico H J Pijls; Jacques J Koolen; Kees-Joost Botman; Herman R Michels; Bart R G Brueren; Kathinka Peels; Naohisa Shindo; Jun Yamashita; Akira Yamashina
Journal:  Heart Vessels       Date:  2011-10-29       Impact factor: 2.037

2.  Usefulness of the RISK-PCI score to predict stent thrombosis in patients treated with primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: a substudy of the RISK-PCI trial.

Authors:  Igor Mrdovic; Lidija Savic; Ratko Lasica; Gordana Krljanac; Milika Asanin; Natasa Brdar; Nemanja Djuricic; Natasa Cvetinovic; Jelena Marinkovic; Jovan Perunicic
Journal:  Heart Vessels       Date:  2012-09-14       Impact factor: 2.037

3.  Effect of myocardial contractility on hemodynamic end points under concomitant microvascular disease in a porcine model.

Authors:  Srikara Viswanath Peelukhana; Kranthi K Kolli; Massoud A Leesar; Mohamed A Effat; Tarek A Helmy; Imran Arif; Eric W Schneeberger; Paul Succop; Rupak K Banerjee
Journal:  Heart Vessels       Date:  2013-04-30       Impact factor: 2.037

4.  Long-Term Clinical Outcomes of New-Generation Drug-Eluting Stents in Coronary Artery Disease: A Real-World Observational Study.

Authors:  Hsun-Hao Chang; Chi-Feng Hung; I-Chih Chen; Po-Ching Wu; Li-Wei Liu; Ching-Chang Fang
Journal:  Acta Cardiol Sin       Date:  2021-09       Impact factor: 2.672

5.  Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention.

Authors:  Zhigeng Jin; Shengli Yang; Limin Jing; Huiliang Liu
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

6.  A rare case of myocardial infarction related to diagnostic intravascular ultrasound.

Authors:  Ken Otsuji; Fumihiko Kamezaki; Shinjo Sonoda; Kuninobu Kashiyama; Yoshitaka Muraoka; Yuki Tsuda; Masaru Araki; Masahiro Okazaki; Masaaki Takeuchi; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2013-03-01       Impact factor: 2.037

7.  Effect of stent inflation pressure and post-dilatation on the outcome of coronary artery intervention. A report of more than 90,000 stent implantations.

Authors:  Ole Fröbert; Giovanna Sarno; Stefan K James; Nawsad Saleh; Bo Lagerqvist
Journal:  PLoS One       Date:  2013-02-13       Impact factor: 3.240

8.  Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study.

Authors:  Jaya Chandrasekhar; Christopher Allada; Simon O'Connor; Moyazur Rahman; Bruce Shadbolt; Ahmad Farshid
Journal:  Int J Cardiol Heart Vessel       Date:  2014-03-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.