Literature DB >> 19085915

Impact of a prolonged delivery inflation time for optimal drug-eluting stent expansion.

Tomohiro Kawasaki1, Hisashi Koga, Takeshi Serikawa, Yoshiya Orita, Shinsuke Ikeda, Takahiro Mito, Yoshitaka Gotou, Yoshiaki Shintani, Atsushi Tanaka, Hidenori Tanaka, Takaya Fukuyama, Nobuhiko Koga.   

Abstract

PURPOSE: We examined the importance of prolonged inflation time for optimal sirolimus-eluting stent (SES) or paclitaxel-eluting stent (PES) expansion.
METHODS: Eighty-one de novo lesions deployed single SES or PES between April 2007 and March 2008 were divided into four groups; group 1: 21 SES deployed at 20 atm x 60 sec, group 2: 20 SES deployed with 2-step inflation at 20 atm x 60 sec following 20 atm x 20 sec, group 3: 20 PES deployed same as group 1, group 4: 20 PES deployed same as group 2. The minimal lumen diameter (MLD) and stent expansion ratio (SER; stent cross- sectional area at lesion/balloon cross-sectional area which was calculated according to the compliance chart at the same atmosphere as stent deployment) were compared between group 1 and group 2 in SES, between group 3 and group 4 in PES.
RESULTS: The MLD of post 60 sec was significantly higher than that of post 20 sec (2.84 +/- 0.28 mm in group 1, 2.76 +/- 0.33 mm in group 2 vs. 2.54 +/- 0.33 mm in group 2; P = 0.003, 0.045, respectively and 2.94 +/- 0.28 mm in group 3, 3.00 +/- 0.34 mm in group 4 vs. 2.69 +/- 0.35 mm in group 4; P = 0.022, 0.007, respectively). The SER of post 60 sec was significantly higher than that of post 20 sec (79.3% +/- 8.5% in group 1, 80.8% +/- 7.8% in group 2 vs. 71.1% +/- 10.2% in group 2; P = 0.014, 0.011, respectively and 81.1% +/- 7.9% in group 3, 84.3% +/- 9.9% in group 4 vs. 72.6% +/- 10.5% in group 4, P = 0.011, 0.001, respectively).
CONCLUSION: The prolonged delivery inflation for 60 sec may result in a more optimal stent expansion. It is therefore considered to be a useful method for deploying drug-eluting stent. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19085915     DOI: 10.1002/ccd.21813

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  5 in total

1.  Approach to Treatment of Bifurcation Lesions.

Authors:  Ihab Alomari; Arnold Seto
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-01

2.  Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Yuki Tsuda; Seiya Tanaka; Masahiro Okazaki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

3.  Compliance charts to guide non-complex small artery stenting: validation by quantitative coronary angiography.

Authors:  Yohan Chacko; J Kimberly Haladyn; Debbie M Smith; Richard Lim
Journal:  Heart Asia       Date:  2013-05-31

Review 4.  Stenting of coronary bifurcation lesions: a literature and technical review.

Authors:  Joo Myung Lee; Kyung Woo Park; Bon-Kwon Koo; Hyo-Soo Kim
Journal:  Curr Cardiol Rep       Date:  2015-06       Impact factor: 2.931

5.  Impact of the Balloon Inflation Time and Pattern on the Coronary Stent Expansion.

Authors:  Jarosław Skowroński; Rafał Wolny; Jan Jastrzębski; Paweł Tyczyński; Karol Szlazak; Jerzy Pręgowski; Gary S Mintz; Karolina Liżewska; Wojciech Świeszkowski; Zbigniew Chmielak; Adam Witkowski
Journal:  J Interv Cardiol       Date:  2019-03-21       Impact factor: 2.279

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.