Literature DB >> 22038109

Assessment of optimum stent deployment by stent boost imaging: comparison with intravascular ultrasound.

Nobuhiro Tanaka1, Nico H J Pijls, Jacques J Koolen, Kees-Joost Botman, Herman R Michels, Bart R G Brueren, Kathinka Peels, Naohisa Shindo, Jun Yamashita, Akira Yamashina.   

Abstract

Stent boost (SB) imaging is an enhancement of the radiologic edge of the stent by digital management of regular X-ray images. The purpose of the present study was to validate SB imaging by comparison with the anatomical standard using intravascular ultrasound (IVUS). We investigated SB and IVUS after stent implantation in 68 arteries in 60 patients. Based on those findings, we added high-pressure dilatation in four patients and another stent implantation in four patients. We defined the SB criteria for adequate stent deployment as: complete stent expansion, stent minimum diameter ≥70% of reference diameter, and stent minimum diameter ≥2.0 mm; and IVUS criteria for adequate stent deployment as: minimal stent area ≥5.0 mm(2). If the reference vessel was <2.8 mm, adequate stent deployment was defined as minimum stent area ≥4.5 mm(2). IVUS findings indicated inadequate stent deployment in 21/72 observations (29%). Seven SB images showed inadequate stent expansion. SB predicted inadequate findings of IVUS with 100% specificity, 33% sensitivity, and 81% agreement. Although the sensitivity of SB image for adequate stent deployment is low, the specificity is sufficiently high for it to be the first-line for monitoring just after stent implantation in centers where IVUS is not used routinely.

Entities:  

Mesh:

Year:  2011        PMID: 22038109     DOI: 10.1007/s00380-011-0202-9

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  10 in total

Review 1.  Routine intravascular ultrasound guidance of percutaneous coronary intervention: a critical reappraisal.

Authors:  James L Orford; Amir Lerman; David R Holmes
Journal:  J Am Coll Cardiol       Date:  2004-04-21       Impact factor: 24.094

2.  Primary percutaneous coronary intervention for acute myocardial infarction due to possible sequelae of Kawasaki disease in young adults: a case series.

Authors:  Makoto Ariyoshi; Jun Shiraishi; Masayoshi Kimura; Akihiro Matsui; Mitsuo Takeda; Masayasu Arihara; Masayuki Hyogo; Takatomo Shima; Takashi Okada; Yoshio Kohno; Takahisa Sawada; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-11-10       Impact factor: 2.037

3.  Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Yuki Tsuda; Seiya Tanaka; Masahiro Okazaki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

4.  Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study.

Authors:  Kenichi Fujii; Stéphane G Carlier; Gary S Mintz; Yi-ming Yang; Issam Moussa; Giora Weisz; George Dangas; Roxana Mehran; Alexandra J Lansky; Edward M Kreps; Michael Collins; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2005-04-05       Impact factor: 24.094

Review 5.  Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysis.

Authors:  Alain Joel Nordmann; Matthias Briel; Heiner Claudins Bucher
Journal:  Eur Heart J       Date:  2006-10-04       Impact factor: 29.983

6.  Stent thrombosis in randomized clinical trials of drug-eluting stents.

Authors:  Laura Mauri; Wen-hua Hsieh; Joseph M Massaro; Kalon K L Ho; Ralph D'Agostino; Donald E Cutlip
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

7.  Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation.

Authors:  Stéphane Cook; Peter Wenaweser; Mario Togni; Michael Billinger; Cyrill Morger; Christian Seiler; Rolf Vogel; Otto Hess; Bernhard Meier; Stephan Windecker
Journal:  Circulation       Date:  2007-05-08       Impact factor: 29.690

8.  Determination of adequate coronary stent expansion using StentBoost, a novel fluoroscopic image processing technique.

Authors:  Jacob M Mishell; Kalpesh T Vakharia; Thomas A Ports; Yerem Yeghiazarians; Andrew D Michaels
Journal:  Catheter Cardiovasc Interv       Date:  2007-01       Impact factor: 2.692

9.  Relation of stent overexpansion to the angiographic no-reflow phenomenon in intravascular ultrasound-guided stent implantation for acute myocardial infarction.

Authors:  Yuichiro Maekawa; Yasushi Asakura; Toshihisa Anzai; Shiro Ishikawa; Teruo Okabe; Tsutomu Yoshikawa; Satoshi Ogawa
Journal:  Heart Vessels       Date:  2005-02       Impact factor: 2.037

10.  Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial.

Authors:  Shinjo Sonoda; Yoshihiro Morino; Junya Ako; Mitsuyasu Terashima; Ali H M Hassan; Heidi N Bonneau; Martin B Leon; Jeffrey W Moses; Paul G Yock; Yasuhiro Honda; Richard E Kuntz; Peter J Fitzgerald
Journal:  J Am Coll Cardiol       Date:  2004-06-02       Impact factor: 24.094

  10 in total
  10 in total

1.  Repression of wall shear stress inside cerebral aneurysm at bifurcation of anterior cerebral artery by stents.

Authors:  Ryuhei Yamaguchi; Gaku Tanaka; Hao Liu; Hiroshi Ujiie
Journal:  Heart Vessels       Date:  2015-03-27       Impact factor: 2.037

2.  Dislodged and mechanically distorted stent stuck within a previously implanted drug-eluting stent.

Authors:  Hiroaki Watabe; Akira Sato; Tomoya Hoshi; Kenichi Obara; Ryo Kawamura; Kazutaka Aonuma
Journal:  Heart Vessels       Date:  2012-09-20       Impact factor: 2.037

3.  Usefulness of the RISK-PCI score to predict stent thrombosis in patients treated with primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: a substudy of the RISK-PCI trial.

Authors:  Igor Mrdovic; Lidija Savic; Ratko Lasica; Gordana Krljanac; Milika Asanin; Natasa Brdar; Nemanja Djuricic; Natasa Cvetinovic; Jelena Marinkovic; Jovan Perunicic
Journal:  Heart Vessels       Date:  2012-09-14       Impact factor: 2.037

4.  Effect of myocardial contractility on hemodynamic end points under concomitant microvascular disease in a porcine model.

Authors:  Srikara Viswanath Peelukhana; Kranthi K Kolli; Massoud A Leesar; Mohamed A Effat; Tarek A Helmy; Imran Arif; Eric W Schneeberger; Paul Succop; Rupak K Banerjee
Journal:  Heart Vessels       Date:  2013-04-30       Impact factor: 2.037

5.  First reported revascularization of complex occlusion of the right coronary artery using the IVUS-guided reverse CART technique via a gastroepiploic artery graft.

Authors:  Jian Dai; Osamu Katoh; Hua Zhou; Eisho Kyo
Journal:  Heart Vessels       Date:  2014-08-23       Impact factor: 2.037

6.  Impact of intravascular ultrasound findings on long-term patency after self-expanding nitinol stent implantation in the iliac artery lesion.

Authors:  Kojiro Miki; Kenichi Fujii; Masashi Fukunaga; Machiko Nishimura; Tetsuo Horimatsu; Ten Saita; Hiroto Tamaru; Takahiro Imanaka; Masahiko Shibuya; Yoshiro Naito; Tohru Masuyama
Journal:  Heart Vessels       Date:  2015-01-21       Impact factor: 2.037

7.  Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention.

Authors:  Zhigeng Jin; Shengli Yang; Limin Jing; Huiliang Liu
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

8.  Angioplasty of unprotected left main coronary stenosis: Real world experience of a single-operator group from eastern India.

Authors:  Shuvanan Ray; Alok Mazumder; Soumitra Kumar; Prithwiraj Bhattacharjee; David Rozario; Siddhartha Bandyopadhyay; Sanjeev S Mukherjee; P K Deb; Amal Bandyopadhyay
Journal:  Indian Heart J       Date:  2016-01-18

9.  Optical coherence tomography: evaluating the effects of stent boost subtract imaging on stent underexpansion in STEMI patients.

Authors:  Yuanyuan Duan; Limin Jing; Shi Pan; Sujuan Yan; Fang Wang; Hong Yu; Beibei Zhang; Guangsheng Wei; Ming Zhang; Jiao Zhang
Journal:  BMC Cardiovasc Disord       Date:  2022-02-20       Impact factor: 2.298

10.  Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study.

Authors:  Jaya Chandrasekhar; Christopher Allada; Simon O'Connor; Moyazur Rahman; Bruce Shadbolt; Ahmad Farshid
Journal:  Int J Cardiol Heart Vessel       Date:  2014-03-19
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.