Literature DB >> 17174865

Comparison of paclitaxel-eluting stent and sirolimus-eluting stent expansion at incremental delivery pressures.

Aamir Javaid1, William W Chu, Edouard Cheneau, Leonardo C Clavijo, Lowell F Satler, Kenneth M Kent, Neil J Weissman, Augusto D Pichard, Ron Waksman.   

Abstract

OBJECTIVES: We sought to compare the adequacy of paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) expansion based on intravascular ultrasound (IVUS) imaging criteria at conventional delivery pressures.
METHODS: Forty-six patients underwent SES implantation and 42 patients underwent PES implantation for de novo native coronary lesions<33 mm in length with reference lumen diameters of 2.5-3.5 mm. Stents were serially expanded with gradual balloon inflations at 14 and 20 atm. IVUS imaging was performed prior to intervention and after each balloon inflation. Stent expansion (minimal stent cross-sectional area/reference lumen cross-sectional area) was measured. Inadequate stent expansion was defined using the MUSIC criteria (all struts apposed, no tissue protrusion, and final lumen cross-sectional area>80% of the reference or >90% if minimal lumen cross-sectional area was <9 mm2).
RESULTS: The baseline characteristics of the two groups were similar except for shorter lesion length, larger mean lumen cross-sectional area, larger lumen diameter, and lower plaque burden in the PES group. Stent expansion was inadequate in 80% of patients with SES versus 63% of patients with PES at 14 atm, although this was not statistically significant. After 20 atm, 48% of patients with SES remained underexpanded as compared with 35% of patients with PES.
CONCLUSION: Drug-eluting stents showed significant underexpansion by MUSIC criteria at conventionally used inflation pressures. Higher balloon inflations are required especially during deployment of a SES. IVUS guidance is recommended to ensure optimal results and outcomes with both stents.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17174865     DOI: 10.1016/j.carrev.2006.09.002

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  3 in total

1.  Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Yuki Tsuda; Seiya Tanaka; Masahiro Okazaki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

2.  Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons.

Authors:  Ashok Seth; Sajal Gupta; Vivudh Pratap Singh; Vijay Kumar
Journal:  Interv Cardiol       Date:  2017-09

3.  Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study.

Authors:  Jaya Chandrasekhar; Christopher Allada; Simon O'Connor; Moyazur Rahman; Bruce Shadbolt; Ahmad Farshid
Journal:  Int J Cardiol Heart Vessel       Date:  2014-03-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.