Literature DB >> 15172398

Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial.

Shinjo Sonoda1, Yoshihiro Morino, Junya Ako, Mitsuyasu Terashima, Ali H M Hassan, Heidi N Bonneau, Martin B Leon, Jeffrey W Moses, Paul G Yock, Yasuhiro Honda, Richard E Kuntz, Peter J Fitzgerald.   

Abstract

OBJECTIVES: We assessed the predictive value of minimum stent area (MSA) for long-term patency of sirolimus-eluting stents (SES) implantation compared to bare metal stents (BMS).
BACKGROUND: Although MSA is a consistent predictor of in-stent restenosis, its predictive value in BMS is still limited because of biologic variability in the restenosis process.
METHODS: From the SIRolImUS (SIRIUS) trial, 122 cases (SES: 72; BMS: 50) with complete serial intravascular ultrasound (IVUS) (baseline and 8-month follow-up) were analyzed. Postprocedure MSA and follow-up minimum lumen area (MLA) were obtained. Based on previous physiologic studies, adequate stent patency at follow-up was defined as MLA >4 mm(2).
RESULTS: In both groups, a significant positive correlation was observed between baseline MSA and follow-up MLA (SES: p < 0.0001, BMS: p < 0.0001). However, SES showed higher correlation than BMS (0.8 vs. 0.65) with a higher regression coefficient (0.92 vs. 0.59). The sensitivity and specificity curves identified different optimal thresholds of MSA to predict adequate follow-up MLA: 5 mm(2) for SES and 6.5 mm(2) for BMS. The positive predictive values with these cutoff points were 90% and 56%, respectively.
CONCLUSIONS: In this SIRIUS IVUS substudy, SES reduced both biologic variability and restenosis, resulting in increased predictability of long-term stent patency with postprocedure MSA. In addition, SES had a considerably lower optimal MSA threshold compared to BMS.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15172398     DOI: 10.1016/j.jacc.2004.01.044

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  53 in total

1.  Long-term angiographic outcomes of post-sirolimus-eluting stent restenosis in Japanese patients.

Authors:  Nobuyuki Miyai; Noriyuki Kinoshita; Keisuke Oota; Takeshi Yamada; Reo Nakamura; Hidekazu Irie; Tetsuo Hashimoto; Shyunichi Tamaki; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-10-27       Impact factor: 2.037

Review 2.  Prediction of protein function and pathways in the genome era.

Authors:  T Gabaldón; M A Huynen
Journal:  Cell Mol Life Sci       Date:  2004-04       Impact factor: 9.261

3.  Assessment of optimum stent deployment by stent boost imaging: comparison with intravascular ultrasound.

Authors:  Nobuhiro Tanaka; Nico H J Pijls; Jacques J Koolen; Kees-Joost Botman; Herman R Michels; Bart R G Brueren; Kathinka Peels; Naohisa Shindo; Jun Yamashita; Akira Yamashina
Journal:  Heart Vessels       Date:  2011-10-29       Impact factor: 2.037

4.  Main branch stent deformation following difficult side branch rewiring and balloon dilatation. Rare complication of provisional T stenting.

Authors:  M Tomasevic; V Vukcevic; G Stankovic; D Orlic; M Ostojic
Journal:  Herz       Date:  2010-09-22       Impact factor: 1.443

5.  Percutaneous coronary intervention for unprotected left main coronary artery stenosis.

Authors:  Seung-Jung Park; Young-Hak Kim
Journal:  World J Cardiol       Date:  2010-04-26

6.  Mechanism of in-stent restenosis after second-generation drug-eluting stents (DES): is it different from bare-metal stents and first-generation DES?

Authors:  Shoichi Kuramitsu; Shinichi Shirai; Kenji Ando
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

7.  Frequency and prognostic impact of intravascular imaging-guided urgent percutaneous coronary intervention in patients with acute myocardial infarction: results from J-MINUET.

Authors:  Hiroyuki Okura; Yoshihiko Saito; Tsunenari Soeda; Koichi Nakao; Yukio Ozaki; Kazuo Kimura; Junya Ako; Teruo Noguchi; Satoshi Yasuda; Satoru Suwa; Kazuteru Fujimoto; Yasuharu Nakama; Takashi Morita; Wataru Shimizu; Atsushi Hirohata; Yasuhiro Morita; Teruo Inoue; Atsunori Okamura; Masaaki Uematsu; Kazuhito Hirata; Kengo Tanabe; Yoshisato Shibata; Mafumi Owa; Kenichi Tsujita; Kunihiro Nishimura; Yoshihiro Miyamoto; Masaharu Ishihara
Journal:  Heart Vessels       Date:  2018-11-02       Impact factor: 2.037

8.  Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Yuki Tsuda; Seiya Tanaka; Masahiro Okazaki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

9.  Post-dilatation after implantation of bioresorbable everolimus- and novolimus-eluting scaffolds: an observational optical coherence tomography study of acute mechanical effects.

Authors:  Florian Blachutzik; Niklas Boeder; Jens Wiebe; Alessio Mattesini; Oliver Dörr; Astrid Most; Timm Bauer; Jens Röther; Monique Tröbs; Christian Schlundt; Stephan Achenbach; Christian W Hamm; Holger M Nef
Journal:  Clin Res Cardiol       Date:  2016-10-18       Impact factor: 5.460

10.  A rare case of myocardial infarction related to diagnostic intravascular ultrasound.

Authors:  Ken Otsuji; Fumihiko Kamezaki; Shinjo Sonoda; Kuninobu Kashiyama; Yoshitaka Muraoka; Yuki Tsuda; Masaru Araki; Masahiro Okazaki; Masaaki Takeuchi; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2013-03-01       Impact factor: 2.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.