Literature DB >> 16483339

Adjunctive balloon postdilatation after stent deployment: is it still necessary with drug-eluting stents?

Bruce R Brodie1.   

Abstract

Deployment of bare metal stents (BMS) with current stent delivery systems is often associated with suboptimal stent expansion. Adjunctive postdilatation with noncompliant balloons has improved stent expansion with BMS and has been associated with less need for target vessel revascularization (TVR). Drug-eluting stents (DES) have proven highly effective in reducing restenosis and TVR and are now being used in the great majority of percutaneous coronary interventions. Because of the very low rates of TVR with DES, many operators have felt that postdilatation may no longer be necessary. In this review, we present data showing that stent expansion of DES (like BMS) using current stent delivery systems is frequently suboptimal. Furthermore, smaller mimimal stent area (MSA) and stent underexpansion following deployment of DES are strong predictors of stent thrombosis and TVR. Adjunctive postdilatation with noncompliant balloons can increase MSA and decrease the frequency of suboptimal stent deployment and potentially can reduce the frequency of stent thrombosis and TVR. Despite the lack of evidence from randomized clinical trials, we believe the observational data support the use of adjunctive balloon postdilatation following deployment of DES in the great majority of patients.

Entities:  

Mesh:

Year:  2006        PMID: 16483339     DOI: 10.1111/j.1540-8183.2006.00103.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  8 in total

Review 1.  Prediction of protein function and pathways in the genome era.

Authors:  T Gabaldón; M A Huynen
Journal:  Cell Mol Life Sci       Date:  2004-04       Impact factor: 9.261

2.  Main branch stent deformation following difficult side branch rewiring and balloon dilatation. Rare complication of provisional T stenting.

Authors:  M Tomasevic; V Vukcevic; G Stankovic; D Orlic; M Ostojic
Journal:  Herz       Date:  2010-09-22       Impact factor: 1.443

3.  Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Yuki Tsuda; Seiya Tanaka; Masahiro Okazaki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

4.  Multi-modality imaging for stent edge assessment.

Authors:  Soe Hee Ann; Kyung Hun Lim; Cai De Jin; Eun-Seok Shin
Journal:  Heart Vessels       Date:  2014-01-31       Impact factor: 2.037

5.  Compliance charts to guide non-complex small artery stenting: validation by quantitative coronary angiography.

Authors:  Yohan Chacko; J Kimberly Haladyn; Debbie M Smith; Richard Lim
Journal:  Heart Asia       Date:  2013-05-31

6.  Overaggressive stent expansion without intravascular imaging: impact on restenosis.

Authors:  Yohan Chacko; Richard Chan; J Kimberly Haladyn; Richard Lim
Journal:  Heart Asia       Date:  2014-02-27

7.  Stent Optimization Using Adjunctive Balloon Dilatation in the Era of Second-Generation Drug-Eluting Stents.

Authors:  Min Chul Kim; Ju Han Kim
Journal:  Korean Circ J       Date:  2017-09-11       Impact factor: 3.243

8.  Additional postdilatation using noncompliant balloons after everolimus-eluting stent implantation: Results of the PRESS trial.

Authors:  Gyung-Min Park; Jae-Hwan Lee; Si Wan Choi; Jin-Ok Jeong; Eun-Seok Shin; Jang-Whan Bae; Hyuck-Jun Yoon; Kyung Tae Jung; Ju Yeol Baek; Woong Gil Choi; Rak Kyeong Choi; Sung-Ho Her; Jin Bae Lee; Jon Suh; Jae Beom Lee; Se-Whan Lee; In-Ho Chae; So-Yeon Choi; In-Whan Seong
Journal:  Clin Cardiol       Date:  2020-03-16       Impact factor: 2.882

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.