Literature DB >> 14724301

A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.

Gregg W Stone1, Stephen G Ellis, David A Cox, James Hermiller, Charles O'Shaughnessy, James Tift Mann, Mark Turco, Ronald Caputo, Patrick Bergin, Joel Greenberg, Jeffrey J Popma, Mary E Russell.   

Abstract

BACKGROUND: Restenosis after coronary stenting necessitates repeated percutaneous or surgical revascularization procedures. The delivery of paclitaxel to the site of vascular injury may reduce the incidence of neointimal hyperplasia and restenosis.
METHODS: At 73 U.S. centers, we enrolled 1314 patients who were receiving a stent in a single, previously untreated coronary-artery stenosis (vessel diameter, 2.5 to 3.75 mm; lesion length, 10 to 28 mm) in a prospective, randomized, double-blind study. A total of 652 patients were randomly assigned to receive a bare-metal stent, and 662 to receive an identical-appearing, slow-release, polymer-based, paclitaxel-eluting stent. Angiographic follow-up was prespecified at nine months in 732 patients.
RESULTS: In terms of base-line characteristics, the two groups were well matched. Diabetes mellitus was present in 24.2 percent of patients; the mean reference-vessel diameter was 2.75 mm, and the mean lesion length was 13.4 mm. A mean of 1.08 stents (length, 21.8 mm) were implanted per patient. The rate of ischemia-driven target-vessel revascularization at nine months was reduced from 12.0 percent with the implantation of a bare-metal stent to 4.7 percent with the implantation of a paclitaxel-eluting stent (relative risk, 0.39; 95 percent confidence interval, 0.26 to 0.59; P<0.001). Target-lesion revascularization was required in 3.0 percent of the group that received a paclitaxel-eluting stent, as compared with 11.3 percent of the group that received a bare-metal stent (relative risk, 0.27; 95 percent confidence interval, 0.16 to 0.43; P<0.001). The rate of angiographic restenosis was reduced from 26.6 percent to 7.9 percent with the paclitaxel-eluting stent (relative risk, 0.30; 95 percent confidence interval, 0.19 to 0.46; P<0.001). The nine-month composite rates of death from cardiac causes or myocardial infarction (4.7 percent and 4.3 percent, respectively) and stent thrombosis (0.6 percent and 0.8 percent, respectively) were similar in the group that received a paclitaxel-eluting stent and the group that received a bare-metal stent.
CONCLUSIONS: As compared with bare-metal stents, the slow-release, polymer-based, paclitaxel-eluting stent is safe and markedly reduces the rates of clinical and angiographic restenosis at nine months. Copyright 2004 Massachusetts Medical Society

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14724301     DOI: 10.1056/NEJMoa032441

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  404 in total

1.  The FDA Review Process for Cardiac Medical Devices in Children: A Review for the Clinician.

Authors:  Christopher S Almond
Journal:  Prog Pediatr Cardiol       Date:  2012-03-27

2.  Concurrent drug eluting/bare metal stent implantation during percutaneous coronary intervention in target vessel: outcomes and 1-year follow-up.

Authors:  Alessandro Cuneo; Peter Bramlage; Matthias Hochadel; Jochen Senges; Christoph Nienaber; Karl-Heinz Kuck; Ulrich Tebbe
Journal:  Clin Res Cardiol       Date:  2011-12-09       Impact factor: 5.460

Review 3.  Percutaneous coronary intervention in diabetics.

Authors:  Juhana Karha; Deepak L Bhatt
Journal:  Rev Endocr Metab Disord       Date:  2004-08       Impact factor: 6.514

4.  Intracoronary brachytherapy for in-stent restenosis: will it remain a viable therapy?

Authors:  Seong-Wook Park; Myeong-Ki Hong; Seung Jun Oh; Dae Hyuk Moon
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-06-16       Impact factor: 9.236

5.  Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis.

Authors:  A Halkin; S Carlier; M B Leon
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

6.  [Drug-coated stents. Where do we stand in 2004?].

Authors:  B Scheller
Journal:  Z Kardiol       Date:  2004-09

7.  Evaluation of in-stent neointimal tissue components using integrated backscatter intravascular ultrasound: comparison of drug-eluting stents and bare-metal stents.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Kuninobu Kashiyama; Fumihiko Kamezaki; Yuki Tsuda; Masaru Araki; Masahiro Okazaki; Yutaka Otsuji
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-18       Impact factor: 2.357

8.  Translational research: current status, challenges and future strategies.

Authors:  Dale Yu
Journal:  Am J Transl Res       Date:  2011-09-12       Impact factor: 4.060

9.  Nanoparticle shape improves delivery: rational coarse grain molecular dynamics (rCG-MD) of taxol in worm-like PEG-PCL micelles.

Authors:  Sharon M Loverde; Michael L Klein; Dennis E Discher
Journal:  Adv Mater       Date:  2011-11-22       Impact factor: 30.849

10.  Outcomes of Patients Treated with the Everolimus- versus the Paclitaxel-Eluting Stents in a Consecutive Cohort of Patients at a Tertiary Medical Center.

Authors:  Nicolas W Shammas; Gail A Shammas; Elie Nader; Michael Jerin; Luay Mrad; Nicholas Ehrecke; Waheeb J Shammas; Cara M Voelliger; Alexander Hafez; Ryan Kelly; Emily Reynolds
Journal:  Int J Angiol       Date:  2013-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.