Literature DB >> 21165184

Accuracy of a proposed implant impression technique using abutments and metal framework.

Hyeok-Jae Lee1, Young-Jun Lim, Chang-Whe Kim, Jung-Han Choi, Myung-Joo Kim.   

Abstract

PURPOSE: This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cementon crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated.
MATERIAL AND METHODS: Three definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks. Ten impressions were made and poured, using each of the 3 techniques on each of the 3 definitive casts. To record the vertical gap between reference frameworks and analogs in duplicate casts, a light microscope with image processing was used. Data were analyzed by two-way analysis of variance and the Tukey test.
RESULTS: The open tray techniques showed significantly smaller vertical gaps compare to closed tray technique (P < .05). The closed tray and the resin-splinted open tray technique showed significantly different vertical gaps according to the angulation of implant (P < .05), but the A-F impression technique did not (P > .05).
CONCLUSION: The accuracy of the A-F impression technique was superior to that of conventional techniques, and was not affected by the angulation of the implants.

Entities:  

Keywords:  Abutment; Angulation; Implant; Metal framework; Vertical gap

Year:  2010        PMID: 21165184      PMCID: PMC2984514          DOI: 10.4047/jap.2010.2.1.25

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  21 in total

1.  Evaluation of impression accuracy for osseointegrated implant supported superstructures.

Authors:  D Herbst; J C Nel; C H Driessen; P J Becker
Journal:  J Prosthet Dent       Date:  2000-05       Impact factor: 3.426

2.  Comparative accuracy of implant impression procedures.

Authors:  D Assif; A Fenton; G Zarb; A Schmitt
Journal:  Int J Periodontics Restorative Dent       Date:  1992       Impact factor: 1.840

3.  Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments.

Authors:  Marcos M Naconecy; Eduardo R Teixeira; Rosemary S A Shinkai; Luis Carlos F Frasca; André Cervieri
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Mar-Apr       Impact factor: 2.804

4.  Master cast accuracy in single-tooth implant replacement cases: an in vitro comparison. A technical note.

Authors:  Paolo Vigolo; Fulvio Fonzi; Zeina Majzoub; Giampiero Cordioli
Journal:  Int J Oral Maxillofac Implants       Date:  2005 May-Jun       Impact factor: 2.804

5.  Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models.

Authors:  Jung-Han Choi; Young-Jun Lim; Soon-Ho Yim; Chang-Whe Kim
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Sep-Oct       Impact factor: 2.804

6.  Comparison of impression techniques for a two-implant 15-degree divergent model.

Authors:  A B Carr
Journal:  Int J Oral Maxillofac Implants       Date:  1992       Impact factor: 2.804

7.  Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks.

Authors:  N L Clelland; M C van Putten
Journal:  Int J Oral Maxillofac Implants       Date:  1997 Nov-Dec       Impact factor: 2.804

8.  A comparative analysis of the accuracy of implant transfer techniques.

Authors:  C C Hsu; P L Millstein; R S Stein
Journal:  J Prosthet Dent       Date:  1993-06       Impact factor: 3.426

9.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.

Authors:  R Adell; U Lekholm; B Rockler; P I Brånemark
Journal:  Int J Oral Surg       Date:  1981-12

10.  Biomechanical considerations in osseointegrated prostheses.

Authors:  R Skalak
Journal:  J Prosthet Dent       Date:  1983-06       Impact factor: 3.426

View more
  2 in total

1.  Evaluation of positional accuracy in multiple implants using four different splinting materials: An in vitro study.

Authors:  Thara Maria Joseph; R Ravichandran; S Lylajam; Prasanth Viswabharan; Kavitha Janardhanan; Smitha Rajeev
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

2.  Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study.

Authors:  G Parameshwari; B Chittaranjan; N Sudhir; C-K Anulekha-Avinash; M Taruna; M Ramureddy
Journal:  J Clin Exp Dent       Date:  2018-04-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.