Literature DB >> 10793388

Evaluation of impression accuracy for osseointegrated implant supported superstructures.

D Herbst1, J C Nel, C H Driessen, P J Becker.   

Abstract

STATEMENT OF PROBLEM: An often-debated issue still exists concerning implant impression techniques, whether to splint impression copings. Different configurations are available for these copings for a variety of manufacturers' implant systems.
PURPOSE: This study evaluated and compared 4 impression techniques in terms of their dimensional accuracy to reproduce implant positions on working casts.
MATERIAL AND METHODS: A master model was designed to simulate a clinical situation. Impressions were made using 4 techniques: (1) tapered impression copings not splinted; (2) squared impression copings not splinted; (3) squared impression copings splinted with autopolymerizing acrylic resin; and (4) squared impression copings with a lateral extension on one side not splinted. Reference points machined onto the master model and onto special healing abutments were compared after abutments were transferred to casts using the 4 techniques. Measurements were made using a Reflex microscope, capable of recording in the x-, y-, and z-dimensions.
RESULTS: The dimensional accuracy was high and, although statistically significant (P =.022; power > 80%), a maximum distortion difference of only 0.31% was registered.
CONCLUSION: The dimensional accuracy of all the techniques was exceptional and the observed differences can be regarded as clinically negligible.

Mesh:

Year:  2000        PMID: 10793388     DOI: 10.1016/s0022-3913(00)70014-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  20 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

Review 2.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

3.  Evaluation of accuracy of direct transfer snapon impression coping closed tray impression technique and direct transfer open tray impression technique: an in vitro study.

Authors:  T Balamurugan; P Manimaran
Journal:  J Indian Prosthodont Soc       Date:  2012-08-19

4.  Accuracy of a proposed implant impression technique using abutments and metal framework.

Authors:  Hyeok-Jae Lee; Young-Jun Lim; Chang-Whe Kim; Jung-Han Choi; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2010-03-31       Impact factor: 1.904

5.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

6.  Accuracy of five implant impression technique: effect of splinting materials and methods.

Authors:  Sang-Jik Lee; Sung-Bum Cho
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

7.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

8.  Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

Authors:  Emir Yuzbasioglu; Hanefi Kurt; Rana Turunc; Halenur Bilir
Journal:  BMC Oral Health       Date:  2014-01-30       Impact factor: 2.757

9.  Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants.

Authors:  F Balouch; E Jalalian; M Nikkheslat; R Ghavamian; Sh Toopchi; F Jallalian; S Jalalian
Journal:  J Dent (Shiraz)       Date:  2013-09

10.  Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Authors:  Rohini Rajendran; N Gopi Chander; Kuttae Vishwanathan Anitha; Balasubramanian Muthukumar
Journal:  Eur Oral Res       Date:  2021-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.