Literature DB >> 1299642

Comparison of impression techniques for a two-implant 15-degree divergent model.

A B Carr1.   

Abstract

To consistently provide passively fitting implant superstructures, an understanding of the accuracy and precision of all phases of fabrication and connection is required. The initial phase of fabrication, ie, impression making and cast forming, was investigated in an earlier report for a mandibular five-implant model. The current study evaluates the accuracy of working casts produced from impressions using two different transfer copings in a 15-degree divergent two-implant posterior mandibular model. While the indirect method is less cumbersome to use, it was found to be less accurate in the prior study. The purpose of this study was to see if the direct method is more precise for this clinical situation. A transfer was deemed effective in producing experimental casts if distances between specified points on the cast agreed with the corresponding distances on the master cast. The absolute value of the difference in distances between experimental and master casts was compared for the two techniques (two-sample t tests). No significant differences were noted (P > .05), and the power of the tests ranged from 0.70 to 0.96 against the one-sided hypothesis that the direct method had a smaller mean absolute difference in distance than the indirect method. This suggests no clear advantage in using the direct method in similar clinical situations. Comparison of these findings to other impression accuracy studies is made.

Mesh:

Year:  1992        PMID: 1299642

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  17 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  Accuracy of a proposed implant impression technique using abutments and metal framework.

Authors:  Hyeok-Jae Lee; Young-Jun Lim; Chang-Whe Kim; Jung-Han Choi; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2010-03-31       Impact factor: 1.904

3.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

4.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

5.  In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study.

Authors:  Sonam Gupta; Aparna Ichalangod Narayan; Dhanasekar Balakrishnan
Journal:  Int J Dent       Date:  2017-02-27

6.  A Comparison of implant impression precision: Different materials and techniques.

Authors:  Mahtab Tabesh; Marzieh Alikhasi; Hakimeh Siadat
Journal:  J Clin Exp Dent       Date:  2018-02-01

7.  Accuracy of different impression materials in parallel and nonparallel implants.

Authors:  Mahroo Vojdani; Kianoosh Torabi; Elham Ansarifard
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

8.  Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants.

Authors:  F Balouch; E Jalalian; M Nikkheslat; R Ghavamian; Sh Toopchi; F Jallalian; S Jalalian
Journal:  J Dent (Shiraz)       Date:  2013-09

9.  Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study.

Authors:  Sunantha Selvaraj; Jayachandran Dorairaj; Jayashree Mohan; Paul Simon
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

10.  The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap.

Authors:  Abolfazl Saboury; Hamid Neshandar Asli; Zahra Dalili Kajan
Journal:  J Dent (Shiraz)       Date:  2017-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.