Literature DB >> 17974110

Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models.

Jung-Han Choi1, Young-Jun Lim, Soon-Ho Yim, Chang-Whe Kim.   

Abstract

PURPOSE: This study evaluated the accuracy of 2 implant-level impression techniques (direct nonsplinted and splinted) for the fabrication of multi-unit internal-connection implant restorations in 2 simulated clinical settings (parallel and divergent) using a laboratory model.
MATERIALS AND METHODS: A dental stone master model was fabricated with 2 pairs of implant replicas. One pair simulated a parallel clinical condition and the other an 8-degree-divergent condition. Ten stone casts were made from vinyl polysiloxane impressions of the master model for each impression technique. Half of the samples were created by a direct nonsplinted technique (square impression copings, custom tray), and the other half were made by a direct splinted technique (square impression copings splinted with autopolymerizing acrylic resin, custom tray). Four strain gauges were fixed on each metal framework to measure the degree of framework deformation for each stone cast in half-Wheatstone-bridge formations. Deformation readings were made twice in 4 directions (anterior, posterior, superior, and inferior). Deformation data were analyzed using repeated-measures analysis of variance at a .05 level of significance.
RESULTS: No significant difference in deformation was found between the direct nonsplinted and splinted samples in either simulated clinical condition (P > .05). No significant difference in deformation was found between the techniques regardless of condition (P > .05).
CONCLUSIONS: Within the limitations of this study, using a 2-implant model, the accuracy of implant-level impressions for internal-connection implant restorations was similar for the direct nonsplinted and splinted techniques in settings with divergence up to 8 degrees.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17974110

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  12 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure.

Authors:  Maria Menini; Paolo Setti; Francesco Pera; Paolo Pera; Paolo Pesce
Journal:  Clin Oral Investig       Date:  2017-09-30       Impact factor: 3.573

3.  Accuracy of a proposed implant impression technique using abutments and metal framework.

Authors:  Hyeok-Jae Lee; Young-Jun Lim; Chang-Whe Kim; Jung-Han Choi; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2010-03-31       Impact factor: 1.904

4.  Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study.

Authors:  Si-Hoon Jo; Kyoung-Il Kim; Jae-Min Seo; Kwang-Yeob Song; Ju-Mi Park; Seung-Geun Ahn
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

5.  In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study.

Authors:  Sonam Gupta; Aparna Ichalangod Narayan; Dhanasekar Balakrishnan
Journal:  Int J Dent       Date:  2017-02-27

6.  Accuracy of different impression materials in parallel and nonparallel implants.

Authors:  Mahroo Vojdani; Kianoosh Torabi; Elham Ansarifard
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

7.  Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants.

Authors:  F Balouch; E Jalalian; M Nikkheslat; R Ghavamian; Sh Toopchi; F Jallalian; S Jalalian
Journal:  J Dent (Shiraz)       Date:  2013-09

8.  A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques.

Authors:  Rupali Patil; Pankaj Kadam; Chetan Oswal; Seema Patil; Shweta Jajoo; Arati Gachake
Journal:  J Int Soc Prev Community Dent       Date:  2016 Mar-Apr

9.  The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap.

Authors:  Abolfazl Saboury; Hamid Neshandar Asli; Zahra Dalili Kajan
Journal:  J Dent (Shiraz)       Date:  2017-12

10.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.