Literature DB >> 9425760

Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks.

N L Clelland1, M C van Putten.   

Abstract

Complete-arch implant prostheses continue to exhibit horizontal and vertical misfit between frameworks and abutments. It has been suggested that these gaps may be eliminated and that restoration-induced stresses may be reduced by luting frameworks to screw-retained abutments intraorally. This study measured and compared the strains generated by clinically acceptable, conventional frameworks were made from a single master cast representing a bone simulant model of an edentulous mandible with five Nobel Biocare implants and 4-mm abutments. Two strain gauges were also embedded in the bone simulant model to measure strains at two locations. Resin-luted frameworks were made by securing abutments to the clinical model with five gold slot screws tightened to 10 Ncm. Strain-indicator readings were recorded at a standardized time following the initial fastening of each prosthesis (n = 3). Mean principal strains were determined and compared using a one-way repeated measures analysis of variance. A statistically significant difference was found in the principal strains between the conventional cast and the resin-luted frameworks. Overall, there was a decrease in the magnitude of strain for the resin-luted frameworks. Intraoral luting of frameworks may decrease the strains produced in the bone around implants.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9425760

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Accuracy of a proposed implant impression technique using abutments and metal framework.

Authors:  Hyeok-Jae Lee; Young-Jun Lim; Chang-Whe Kim; Jung-Han Choi; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2010-03-31       Impact factor: 1.904

2.  Stress on external hexagon and Morse taper implants submitted to immediate loading.

Authors:  Caroline H Odo; Marcele J Pimentel; Rafael L X Consani; Marcelo F Mesquita; Mauro A A Nóbilo
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-29

3.  Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses.

Authors:  Mi-Young Lee; Seong-Joo Heo; Eun-Jin Park; Ji-Man Park
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.