Literature DB >> 8320644

A comparative analysis of the accuracy of implant transfer techniques.

C C Hsu1, P L Millstein, R S Stein.   

Abstract

Four different implant transfer techniques using two master cast systems (solid cast and Zeiser system) were evaluated and compared with respect to the accuracy with which abutment positions were reproduced. A stainless steel experimental analogue with two anterior and two posterior fixtures and abutments was fabricated. Polyether impressions (14 each) were made by use of four techniques, (I) nonsplinted, (II) splinted with dental floss and acrylic resin, (III) splinted with orthodontic wire and acrylic resin, and (IV) splinted with acrylic resin alone. The fourteen impressions of each technique were divided into two equal groups: group 1, solid cast system, and group 2, Zeiser system. The abutments of each master cast were measured vertically and horizontally with a profile projector. Statistical analysis indicated no significant difference between the splinted and nonsplinted techniques. The Zeiser system provided more accurate interabutment relationships for the posterior region than the solid cast system.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8320644     DOI: 10.1016/0022-3913(93)90287-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  16 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

Review 2.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

3.  Accuracy of a proposed implant impression technique using abutments and metal framework.

Authors:  Hyeok-Jae Lee; Young-Jun Lim; Chang-Whe Kim; Jung-Han Choi; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2010-03-31       Impact factor: 1.904

4.  Accuracy of five implant impression technique: effect of splinting materials and methods.

Authors:  Sang-Jik Lee; Sung-Bum Cho
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

5.  In vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutments.

Authors:  Anderson Almeida Castilho; Alberto Noriyuki Kojima; Sarina Maciel Braga Pereira; Diego Klee de Vasconcellos; Marcos Koiti Itinoche; Renata Faria; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2007-06       Impact factor: 2.698

6.  A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment.

Authors:  Pâmela Cândida Aires Ribas de Andrade; Leonardo Flores Luthi; Kyle Stanley; Antônio Carlos Cardoso
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

7.  Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants.

Authors:  F Balouch; E Jalalian; M Nikkheslat; R Ghavamian; Sh Toopchi; F Jallalian; S Jalalian
Journal:  J Dent (Shiraz)       Date:  2013-09

8.  A sectional-splinting technique for impressing multiple implant units by eliminating the use of an open tray.

Authors:  Suryakant C Deogade; Gunjan Dube
Journal:  Contemp Clin Dent       Date:  2014-04

9.  Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study.

Authors:  Sunantha Selvaraj; Jayachandran Dorairaj; Jayashree Mohan; Paul Simon
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

10.  The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap.

Authors:  Abolfazl Saboury; Hamid Neshandar Asli; Zahra Dalili Kajan
Journal:  J Dent (Shiraz)       Date:  2017-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.