Literature DB >> 17709830

PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.

Martin S Judenhofer1, Ciprian Catana, Brian K Swann, Stefan B Siegel, Wulf-Ingo Jung, Robert E Nutt, Simon R Cherry, Claus D Claussen, Bernd J Pichler.   

Abstract

PURPOSE: To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager.
MATERIALS AND METHODS: All animal experiments were performed in accordance with the University of Tübingen guidelines and the German law for the protection of animals. A compact lutetium oxyorthosilicate-avalanche photodiode PET detector was built and optimized to operate within a 7-T MR imager. The detector performance was investigated both outside and inside the magnet, and MR image quality was evaluated with and without the PET detector. Two PET detectors were set up opposite each other and operated in coincidence to acquire PET images in the step-and-shoot mode in a mouse head specimen after injection of fluorine 18 fluorodeoxyglucose.
RESULTS: The performance of the PET detector when operated inside the magnet during MR image acquisition showed little degradation in energy resolution (increase from 14.6% to 15.9%). The PET detector did not influence MR imaging. The fused PET and MR images showed an anatomic match and no degradation of image quality.
CONCLUSION: Simultaneous PET and MR imaging with a 7-T system was deemed feasible. Copyright (c) RSNA, 2007.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17709830     DOI: 10.1148/radiol.2443061756

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  37 in total

1.  Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T.

Authors:  Hans F Wehrl; Martin S Judenhofer; Axel Thielscher; Petros Martirosian; Fritz Schick; Bernd J Pichler
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

2.  Simultaneous in vivo positron emission tomography and magnetic resonance imaging.

Authors:  Ciprian Catana; Daniel Procissi; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Russell E Jacobs; Simon R Cherry
Journal:  Proc Natl Acad Sci U S A       Date:  2008-03-04       Impact factor: 11.205

Review 3.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

4.  A look ahead: PET/MR versus PET/CT.

Authors:  Gustav K von Schulthess; Heinz-Peter W Schlemmer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 5.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 6.  Content-based medical image retrieval: a survey of applications to multidimensional and multimodality data.

Authors:  Ashnil Kumar; Jinman Kim; Weidong Cai; Michael Fulham; Dagan Feng
Journal:  J Digit Imaging       Date:  2013-12       Impact factor: 4.056

Review 7.  Clinical and research applications of simultaneous positron emission tomography and MRI.

Authors:  F Fraioli; S Punwani
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

8.  Simultaneous imaging of magnetic resonance imaging and positron emission tomography by means of MRI-compatible optic fiber-based PET: a validation study in ex vivo rat brain.

Authors:  Masao Imaizumi; Seiichi Yamamoto; Makoto Kawakami; Masaaki Aoki; Eiji Sugiyama; Yasukazu Kanai; Eku Shimosegawa; Jun Hatazawa
Journal:  Jpn J Radiol       Date:  2009-07-22       Impact factor: 2.374

9.  Feasibility of template-guided attenuation correction in cat brain PET imaging.

Authors:  Jin Su Kim; Jae Sung Lee; Min-Hyun Park; Kyeong Min Kim; Seung-Ha Oh; Gi Jeong Cheon; In Chan Song; Dae Hyuk Moon; June-Key Chung; Dong Soo Lee
Journal:  Mol Imaging Biol       Date:  2009-12-01       Impact factor: 3.488

Review 10.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.