Literature DB >> 29915669

Performance Comparison of Different Readouts for Position-Sensitive Solid-State Photomultiplier Arrays.

Junwei Du1, Jeffrey P Schmall1, Kun Di1, Yongfeng Yang1, Purushottam A Dokhale2, Kanai S Shah2, Simon R Cherry1.   

Abstract

A thorough comparison of five different readouts for reading out a 2 × 2 array of 5 mm × 5 mm position-sensitive solid-state photomultipliers (PS-SSPM) was undertaken. The five readouts include reading out the 20 signals (16 position and 4 timing) individually, two signal multiplexing readouts, and two position decoding readouts. Flood histogram quality, signal-to-noise ratio (SNR) and energy resolution were compared at different bias voltage (27.0 V to 32.0 V, at 0.5 V intervals) and at a fixed temperature of 0 °C by coupling a 6 × 6 array of 1.3 mm × 1.3 mm × 20 mm polished LSO crystals to the center of the PS-SSPM array. The timing resolution was measured at a bias voltage of 31.0 V (optimal bias voltage in terms of flood histogram quality). The best flood histogram quality value and signal-to-noise were 7.3 ± 1.6 and 33.5 ± 3.1, respectively, and were obtained by shaping and digitizing the 16 position signals individually. The capacitive charge-division readout is the simplest readout among the five evaluated but still resulted in good performance with a flood histogram quality value of 3.3 ± 0.4 and a SNR of 18.3 ± 1.3. The average energy resolution and the average timing resolution were 15.2 ± 1.2 % and 8.4 ± 1.6 ns for individual signal readout and 15.9 ± 1.2 % and 8.8 ± 1.3 ns by using the capacitive charge-division readout method. These studies show that for an ultra-high spatial resolution applications using the 2 × 2 PS-SSPM array, reading out the 20 signals individually is necessary; whilst the capacitive charge-division readout is a cost-effective readout for less demanding applications.

Entities:  

Keywords:  PET; charge division readout; position-sensitive solid-state photomultipliers

Year:  2017        PMID: 29915669      PMCID: PMC6003720          DOI: 10.1088/2057-1976/aa7c6a

Source DB:  PubMed          Journal:  Biomed Phys Eng Express        ISSN: 2057-1976


  16 in total

Review 1.  The challenge of detector designs for PET.

Authors:  Thomas K Lewellen
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

2.  Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors.

Authors:  Martin S Judenhofer; Bernd J Pichler; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-07       Impact factor: 3.609

Review 3.  Multimodality in vivo imaging systems: twice the power or double the trouble?

Authors:  Simon R Cherry
Journal:  Annu Rev Biomed Eng       Date:  2006       Impact factor: 9.590

4.  Evaluation of Matrix9 silicon photomultiplier array for small-animal PET.

Authors:  Junwei Du; Jeffrey P Schmall; Yongfeng Yang; Kun Di; Emilie Roncali; Gregory S Mitchell; Steve Buckley; Carl Jackson; Simon R Cherry
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

Review 5.  Applications for preclinical PET/MRI.

Authors:  Martin S Judenhofer; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2013-01       Impact factor: 4.446

6.  First characterization of a digital SiPM based time-of-flight PET detector with 1 mm spatial resolution.

Authors:  Stefan Seifert; Gerben van der Lei; Herman T van Dam; Dennis R Schaart
Journal:  Phys Med Biol       Date:  2013-04-15       Impact factor: 3.609

7.  A Simple Capacitive Charge-Division Readout for Position-Sensitive Solid-State Photomultiplier Arrays.

Authors:  Junwei Du; Jeffrey P Schmall; Yongfeng Yang; Kun Di; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2013-10       Impact factor: 1.679

8.  Analog signal multiplexing for PSAPD-based PET detectors: simulation and experimental validation.

Authors:  Frances W Y Lau; Arne Vandenbroucke; Paul D Reynolds; Peter D Olcott; Mark A Horowitz; Craig S Levin
Journal:  Phys Med Biol       Date:  2010-11-16       Impact factor: 3.609

9.  Signal and noise properties of position-sensitive avalanche photodiodes.

Authors:  Yongfeng Yang; Yibao Wu; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2011-09-06       Impact factor: 3.609

10.  Investigation of analog charge multiplexing schemes for SiPM based PET block detectors.

Authors:  Evan Downie; Xin Yang; Hao Peng
Journal:  Phys Med Biol       Date:  2013-05-16       Impact factor: 3.609