Literature DB >> 20966059

Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application.

N V Patel1, M J Gounis, A K Wakhloo, N Noordhoek, J Blijd, D Babic, D Takhtani, S-K Lee, A Norbash.   

Abstract

BACKGROUND AND
PURPOSE: With modern imaging techniques, visualization of neurovascular stents remains challenging. We present a method for contrast-enhanced C-arm CBCT that provides detailed and simultaneous visualization of neurovascular stents and host arteries.
MATERIALS AND METHODS: CBCT was performed with a rotational angiography system by acquiring 620 projection frames over a 200° arc at 80 kVp and a total of 260 mAs. A superselective intra-arterial contrast injection protocol was optimized in swine experiments and implemented in 57 clinical examinations. High-resolution 3D reconstructions were evaluated by 3 blinded interventional neuroradiologists. Reviewers rated the images by answering questions related to both the quality of the stent and artery visualization and the clinical utility of the images. Raw agreement statistics, ICC, and κ statistics were computed for the questionnaire results.
RESULTS: Of 57 clinical evaluations, 5 were not evaluated due to the use of large balloon-mounted stents (n = 4) and a failed contrast injection (n = 1). In 50 of 52 evaluated examinations, the reviewers agreed that simultaneous stent and vessel visualization was of diagnostic quality. There was strong agreement that stent-vessel wall apposition could be assessed (κ = 0.79). CBCT detected contrast filling defects (κ = 0.85) and vascular calcification (κ = 0.68). Artifacts resulting from the aneurysm coil mass impaired the delineation of adjacent structures (κ = 0.72).
CONCLUSIONS: We have developed a technique that enables simultaneous clinically useful imaging of neurovascular stents and their host arteries that is unobtainable with other current imaging modalities. Further improvements are required to reduce artifacts from large coil masses due to x-ray scattering.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20966059      PMCID: PMC7964932          DOI: 10.3174/ajnr.A2239

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  25 in total

1.  Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen.

Authors:  P H Grewe; T Deneke; A Machraoui; J Barmeyer; K M Müller
Journal:  J Am Coll Cardiol       Date:  2000-01       Impact factor: 24.094

2.  Appearance of the neuroform stent on computed tomography angiographic images: imaging pitfall. Case illustration.

Authors:  Kenneth R Curtin; Matthew T Walker; Ali Shaibani
Journal:  J Neurosurg       Date:  2007-12       Impact factor: 5.115

3.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

4.  Pathological mechanisms of fatal late coronary stent thrombosis in humans.

Authors:  Andrew Farb; Allen P Burke; Frank D Kolodgie; Renu Virmani
Journal:  Circulation       Date:  2003-09-22       Impact factor: 29.690

5.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

Review 6.  Treatment of atherosclerotic intracranial arterial stenosis.

Authors:  Tanya N Turan; Colin P Derdeyn; David Fiorella; Marc I Chimowitz
Journal:  Stroke       Date:  2009-04-30       Impact factor: 7.914

7.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

8.  Stent-assisted reconstructive endovascular repair of cranial fusiform atherosclerotic and dissecting aneurysms: long-term clinical and angiographic follow-up.

Authors:  Ajay K Wakhloo; Jake Mandell; Matthew J Gounis; Christopher Brooks; Italo Linfante; Jesse Winer; John P Weaver
Journal:  Stroke       Date:  2008-09-04       Impact factor: 7.914

9.  Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results.

Authors:  Jacques Sedat; Yves Chau; Lydiane Mondot; Julian Vargas; Jacek Szapiro; Michel Lonjon
Journal:  Neuroradiology       Date:  2009-02-25       Impact factor: 2.804

10.  Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting.

Authors:  Jan-Hendrik Buhk; Paul Lingor; Michael Knauth
Journal:  Neuroradiology       Date:  2008-02-02       Impact factor: 2.804

View more
  26 in total

1.  Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.

Authors:  A Rouchaud; C Ramana; W Brinjikji; Y-H Ding; D Dai; T Gunderson; J Cebral; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

2.  The effect of intracranial stent implantation on the curvature of the cerebrovasculature.

Authors:  R M King; J-Y Chueh; I M J van der Bom; C F Silva; S L Carniato; G Spilberg; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-26       Impact factor: 3.825

3.  Artifacts caused by insufficient contrast medium filling during C-arm cone-beam CT scans: a phantom study.

Authors:  Mitsuaki Terabe; Hajime Ichikawa; Toyohiro Kato; Kichiro Koshida
Journal:  Radiol Phys Technol       Date:  2013-06-18

4.  Dose reduction in cone-beam CT scanning for intracranial stent deployment before coil embolization of intracranial wide-neck aneurysms.

Authors:  Takumi Kuriyama; Nobuyuki Sakai; Norimitsu Niida; Masaki Sueoka; Mikiya Beppu; Chihebeddine Dahmani; Iwao Kojima; Chiaki Sakai; Hirotoshi Imamura; Katsuhiro Masago; Nobuyuki Katakami
Journal:  Interv Neuroradiol       Date:  2016-02-24       Impact factor: 1.610

5.  Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery.

Authors:  Seisaku Kanayama; Takayuki Hara; Yusuke Hamada; Yuji Matsumaru
Journal:  Neuroradiology       Date:  2014-11-05       Impact factor: 2.804

6.  CT reconstruction and MRI fusion of 3D rotational angiography in the evaluation of pediatric cerebrovascular lesions.

Authors:  Prakash Muthusami; Nicholas Shkumat; Vanessa Rea; Albert H Chiu; Manohar Shroff
Journal:  Neuroradiology       Date:  2017-03-27       Impact factor: 2.804

7.  Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

Authors:  Michael Lettau; Martin Bendszus; Stefan Hähnel
Journal:  Neuroradiology       Date:  2013-02-15       Impact factor: 2.804

8.  Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium.

Authors:  K I Jo; S R Kim; J H Choi; K H Kim; P Jeon
Journal:  Neuroradiology       Date:  2015-08-21       Impact factor: 2.804

9.  Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Gerhard Kleinszig; Sebastian Vogt; Gary L Gallia; A Jay Khanna; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

10.  Role of C-arm VasoCT in the use of endovascular WEB flow disruption in intracranial aneurysm treatment.

Authors:  J Caroff; C Mihalea; H Neki; D Ruijters; L Ikka; N Benachour; J Moret; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-13       Impact factor: 3.825

View more