Literature DB >> 24504126

Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction.

Adam S Wang1, J Webster Stayman, Yoshito Otake, Gerhard Kleinszig, Sebastian Vogt, Gary L Gallia, A Jay Khanna, Jeffrey H Siewerdsen.   

Abstract

The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼ 40-80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4-2.2 × over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼ 1.7 mGy and benefits from 50% sparsity at dose below ∼ 1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose.

Entities:  

Mesh:

Year:  2014        PMID: 24504126      PMCID: PMC4046706          DOI: 10.1088/0031-9155/59/4/1005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  60 in total

1.  Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware.

Authors:  K Mueller; R Yagel
Journal:  IEEE Trans Med Imaging       Date:  2000-12       Impact factor: 10.048

Review 2.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

Review 3.  Spontaneous abdominal hemorrhage: causes, CT findings, and clinical implications.

Authors:  Alessandro Furlan; Saeed Fakhran; Michael P Federle
Journal:  AJR Am J Roentgenol       Date:  2009-10       Impact factor: 3.959

4.  Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms.

Authors:  Joshua D Evans; David G Politte; Bruce R Whiting; Joseph A O'Sullivan; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

Review 5.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

6.  Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results.

Authors:  R Fahrig; A J Fox; S Lownie; D W Holdsworth
Journal:  AJNR Am J Neuroradiol       Date:  1997-09       Impact factor: 3.825

7.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

8.  Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments--a phantom approach.

Authors:  Frédéric A Miéville; François Gudinchet; Francis Brunelle; François O Bochud; Francis R Verdun
Journal:  Phys Med       Date:  2012-01-02       Impact factor: 2.685

9.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

10.  Prism representation: a 3D ray-tracing algorithm for radiotherapy applications.

Authors:  R L Siddon
Journal:  Phys Med Biol       Date:  1985-08       Impact factor: 3.609

View more
  32 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

3.  Iterative CT Reconstruction using Models of Source and Detector Blur and Correlated Noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2014

4.  Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; A Jay Khanna; Gary L Gallia; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

5.  A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

Authors:  Scott S Hsieh; David A Chesler; Dominik Fleischmann; Norbert J Pelc
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

6.  Image quality evaluation of small FOV and large FOV CBCT devices for oral and maxillofacial radiology.

Authors:  Jean-Philippe Dillenseger; Catherine-Isabelle Gros; Amira Sayeh; Johary Rasamimanana; Fabrice Lawniczak; Jean-Marie Leminor; Jean-François Matern; André Constantinesco; Fabien Bornert; Philippe Choquet
Journal:  Dentomaxillofac Radiol       Date:  2016-09-21       Impact factor: 2.419

7.  Convergence criterion for MBIR based on the local noise-power spectrum: Theory and implementation in a framework for accelerated 3D image reconstruction with a morphological pyramid.

Authors:  A Sisniega; J W Stayman; S Capostagno; C R Weiss; T Ehtiati; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-05-28

8.  Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT.

Authors:  Qian Cao; Wojciech Zbijewski; Alejandro Sisniega; John Yorkston; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

9.  dPIRPLE: a joint estimation framework for deformable registration and penalized-likelihood CT image reconstruction using prior images.

Authors:  H Dang; A S Wang; Marc S Sussman; J H Siewerdsen; J W Stayman
Journal:  Phys Med Biol       Date:  2014-08-06       Impact factor: 3.609

10.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.