Literature DB >> 23775309

Artifacts caused by insufficient contrast medium filling during C-arm cone-beam CT scans: a phantom study.

Mitsuaki Terabe1, Hajime Ichikawa, Toyohiro Kato, Kichiro Koshida.   

Abstract

We investigated artifacts due to late-arriving contrast medium (CM) during C-arm cone-beam computed tomography. We scanned a phantom filled with water or with 100, 50, or 5% v/v concentrations of CM and then virtually produced CM-delayed projection data by partially replacing the projection images. Artifacts as a function of concentration, percentage of filling time, and size and position of the filling area were assessed. In addition, we used an automatic power injector with different injection delays to inject CM during the scans. A decrease in filling times caused by a lag in CM arrival during the scan resulted in a decrease in pixel values, distortion of the filling area, and appearance of streak artifacts. Even a delay of approximately 20% in CM arrival in the total scan time resulted in obvious distortion of the filling area. The distortion and streak artifacts tended to worsen at higher CM concentrations. Use of a minimum CM concentration based on the purpose of the examination and constant filling at the target region are effective for avoiding these artifacts.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23775309     DOI: 10.1007/s12194-013-0227-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  15 in total

1.  Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application.

Authors:  N V Patel; M J Gounis; A K Wakhloo; N Noordhoek; J Blijd; D Babic; D Takhtani; S-K Lee; A Norbash
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

2.  Detection of corona enhancement of hypervascular hepatocellular carcinoma by C-arm dual-phase cone-beam CT during hepatic arteriography.

Authors:  Shiro Miyayama; Masashi Yamashiro; Miho Okuda; Yuichi Yoshie; Yoshiko Nakashima; Hiroshi Ikeno; Nobuaki Orito; Osamu Matsui
Journal:  Cardiovasc Intervent Radiol       Date:  2010-03-24       Impact factor: 2.740

Review 3.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

4.  Optimizing imaging quality in endourology with the Uro Dyna-CT: contrast agent dilution matters.

Authors:  M Ritter; C Weiss; M-C Rassweiler; M S Michel; A Häcker
Journal:  World J Urol       Date:  2012-07-12       Impact factor: 4.226

5.  Optimal contrast material concentration for distinguishing among carotid artery lumen, carotid stent, and neck in cone-beam computed tomography during carotid angiography: basic and clinical studies.

Authors:  Seiki Hosokawa; Nobuyuki Kawai; Morio Sato; Hiroki Minamiguchi; Motoki Nakai; Tadayoshi Nishioku; Tetsuo Sonomura; Hiroyuki Matsumoto; Osamu Masuo; Toru Itakura
Journal:  Jpn J Radiol       Date:  2012-01-17       Impact factor: 2.374

6.  Does safe dosing of iodinated contrast prevent contrast-induced acute kidney injury?

Authors:  Jeremiah R Brown; John F Robb; Clay A Block; Anton C Schoolwerth; Aaron V Kaplan; Gerald T O'Connor; Richard J Solomon; David J Malenka
Journal:  Circ Cardiovasc Interv       Date:  2010-06-29       Impact factor: 6.546

7.  The utility of angiographic CT in the diagnosis and treatment of neurovascular pathologies in the vicinity of cranial base.

Authors:  Jun Li; Feng Wan; Gang Chen; Lianting Ma; Ge Zhang; Guozheng Xu; Jie Gong
Journal:  Neurosurg Rev       Date:  2010-12-04       Impact factor: 3.042

8.  Intracranial vascular stenosis and occlusive disease: evaluation with CT angiography, MR angiography, and digital subtraction angiography.

Authors:  Suzie Bash; J Pablo Villablanca; Reza Jahan; Gary Duckwiler; Monica Tillis; Chelsea Kidwell; Jeffrey Saver; James Sayre
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

9.  Cone-Beam CT with a Flat-Panel Detector: From Image Science to Image-Guided Surgery.

Authors:  Jeffrey H Siewerdsen
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-08-21       Impact factor: 1.455

10.  C-arm CT during hepatic arteriography tumour-to-liver contrast: intraindividual comparison of three different contrast media application protocols.

Authors:  Claus Koelblinger; Wolfgang Schima; Vanessa Berger-Kulemann; Florian Wolf; Christina Plank; Michael Weber; Johannes Lammer
Journal:  Eur Radiol       Date:  2012-11-09       Impact factor: 5.315

View more
  1 in total

1.  Application of low injection rate and low contrast agent dose in three-dimensional rotational digital subtraction angiography of the intracranial aneurysm.

Authors:  Zhimei Gao; Yongming Zeng; Jingkun Sun; Jingjie Yang; Yang Zhou; Mi Zhou; Tingni Song
Journal:  Interv Neuroradiol       Date:  2016-02-24       Impact factor: 1.610

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.