Literature DB >> 24524918

Role of C-arm VasoCT in the use of endovascular WEB flow disruption in intracranial aneurysm treatment.

J Caroff1, C Mihalea2, H Neki2, D Ruijters3, L Ikka2, N Benachour2, J Moret2, L Spelle2.   

Abstract

BACKGROUND AND
PURPOSE: The WEB aneurysm embolization system is still under evaluation but seems to be a promising technique to treat wide-neck bifurcation aneurysms. However, this device is barely visible using conventional DSA; thus, high-resolution contrast-enhanced flat panel detector CT (VasoCT) may be useful before detachment to assess the sizing and positioning of the WEB. The purpose of this study was to evaluate the interest of VasoCT during WEB procedures.
MATERIALS AND METHODS: From March 2012 to July 2013, twelve patients (10 women and 2 men; age range, 44-55 years) were treated for 13 intracranial aneurysms with the WEB device. DSA and VasoCT were used and compared to depict any protrusion of the device in parent arteries before detachment. Two neuroradiologists reviewed each VasoCT scan, and the quality was graded on a subjective quality scale.
RESULTS: The mesh of the WEB was very well-depicted in all cases, allowing a very good assessment of its deployment. Device protrusion was clearly detected with VasoCT in 5 cases, leading to WEB repositioning or size substitution. During follow-up, VasoCT also allows good assessment of eventual residual blood flow inside the aneurysm or the WEB device.
CONCLUSIONS: Unlike DSA, VasoCT is an excellent tool to assess WEB deployment and positioning. In our experience, it allowed a precise evaluation of the WEB sizing and its relation to the parent vessel. Such information very likely enhances the ability to safely use this device, avoiding potential thromboembolic events in cases of protrusion in the parent arteries.
© 2014 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2014        PMID: 24524918      PMCID: PMC7966600          DOI: 10.3174/ajnr.A3860

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  12 in total

1.  Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application.

Authors:  N V Patel; M J Gounis; A K Wakhloo; N Noordhoek; J Blijd; D Babic; D Takhtani; S-K Lee; A Norbash
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

2.  Angiographic CT in cerebrovascular stenting.

Authors:  Götz Benndorf; Charles M Strother; Benjamin Claus; Ramin Naeini; Hesham Morsi; Richard Klucznik; Michael E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

3.  WEB device for endovascular treatment of wide-neck bifurcation aneurysms.

Authors:  B Lubicz; B Mine; L Collignon; D Brisbois; G Duckwiler; C Strother
Journal:  AJNR Am J Neuroradiol       Date:  2013-01-04       Impact factor: 3.825

4.  The Woven EndoBridge cerebral aneurysm embolization device (WEB II): initial clinical experience.

Authors:  Joachim Klisch; Vojtech Sychra; Christoph Strasilla; Thomas Liebig; David Fiorella
Journal:  Neuroradiology       Date:  2011-05-27       Impact factor: 2.804

5.  The Woven EndoBridge: a new aneurysm occlusion device.

Authors:  Y H Ding; D A Lewis; R Kadirvel; D Dai; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2011-02-17       Impact factor: 3.825

6.  Intrasaccular flow-disruption treatment of intracranial aneurysms: preliminary results of a multicenter clinical study.

Authors:  L Pierot; T Liebig; V Sychra; K Kadziolka; F Dorn; C Strasilla; C Kabbasch; J Klisch
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-07       Impact factor: 3.825

7.  Endovascular WEB flow disruption in middle cerebral artery aneurysms: preliminary feasibility, clinical, and anatomical results in a multicenter study.

Authors:  Laurent Pierot; Joachim Klisch; Christophe Cognard; Istvan Szikora; Benjamin Mine; Krzysztof Kadziolka; Vojtech Sychra; Istvan Gubucz; Anne-Christine Januel; Boris Lubicz
Journal:  Neurosurgery       Date:  2013-07       Impact factor: 4.654

8.  Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling.

Authors:  I M J van der Bom; S Y Hou; A S Puri; G Spilberg; D Ruijters; P van de Haar; B Carelsen; S Vedantham; M J Gounis; A K Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-30       Impact factor: 3.825

9.  High-resolution 3D X-ray imaging of intracranial nitinol stents.

Authors:  Rudolph M Snoeren; Michael Söderman; Johannes N Kroon; Ruben B Roijers; Peter H N de With; Drazenko Babic
Journal:  Neuroradiology       Date:  2011-02-18       Impact factor: 2.804

10.  A national survey on radiation dose in CT in The Netherlands.

Authors:  A J van der Molen; A Schilham; P Stoop; M Prokop; J Geleijns
Journal:  Insights Imaging       Date:  2013-05-15
View more
  18 in total

1.  Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.

Authors:  A Rouchaud; C Ramana; W Brinjikji; Y-H Ding; D Dai; T Gunderson; J Cebral; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

2.  Single-Layer WEBs: Intrasaccular Flow Disrupters for Aneurysm Treatment—Feasibility Results from a European Study.

Authors:  J Caroff; C Mihalea; J Klisch; C Strasilla; A Berlis; T Patankar; W Weber; D Behme; E A Jacobsen; T Liebig; S Prothmann; C Cognard; T Finkenzeller; J Moret; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-09       Impact factor: 3.825

3.  Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery.

Authors:  Seisaku Kanayama; Takayuki Hara; Yusuke Hamada; Yuji Matsumaru
Journal:  Neuroradiology       Date:  2014-11-05       Impact factor: 2.804

4.  Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium.

Authors:  K I Jo; S R Kim; J H Choi; K H Kim; P Jeon
Journal:  Neuroradiology       Date:  2015-08-21       Impact factor: 2.804

5.  Occlusion assessment of intracranial aneurysms treated with the WEB device.

Authors:  Jildaz Caroff; Cristian Mihalea; Titien Tuilier; Xavier Barreau; Christophe Cognard; Hubert Desal; Laurent Pierot; Armelle Arnoux; Jacques Moret; Laurent Spelle
Journal:  Neuroradiology       Date:  2016-06-16       Impact factor: 2.804

6.  Intrasaccular Flow Disruption in Acutely Ruptured Aneurysms: A Multicenter Retrospective Review of the Use of the WEB.

Authors:  T Liebig; C Kabbasch; C Strasilla; A Berlis; W Weber; L Pierot; T Patankar; X Barreau; J Dervin; A Kuršumović; S Rath; B Lubicz; J Klisch
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-02       Impact factor: 3.825

7.  Residual Flow Inside the Woven EndoBridge Device at Follow-Up: Potential Predictors of the Bicêtre Occlusion Scale Score 1 Phenomenon.

Authors:  M T Nawka; A Lohse; M Bester; J Fiehler; J-H Buhk
Journal:  AJNR Am J Neuroradiol       Date:  2020-06-25       Impact factor: 3.825

8.  Large Basilar Apex Aneurysms Treated with Flow-Diverter Stents.

Authors:  V Da Ros; J Caroff; A Rouchaud; C Mihalea; L Ikka; J Moret; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-27       Impact factor: 3.825

9.  Woven Endobridge (WEB) Device for endovascular treatment of ruptured intracranial wide-neck aneurysms: a single-center experience.

Authors:  Jildaz Caroff; Cristian Mihalea; Francesco Dargento; Hiroaki Neki; Léon Ikka; Nidhal Benachour; Jacques Moret; Laurent Spelle
Journal:  Neuroradiology       Date:  2014-06-15       Impact factor: 2.804

10.  Flow-Diverter Stents for the Treatment of Saccular Middle Cerebral Artery Bifurcation Aneurysms.

Authors:  J Caroff; H Neki; C Mihalea; F D'Argento; H Abdel Khalek; L Ikka; J Moret; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-24       Impact factor: 3.825

View more