Literature DB >> 25370477

Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery.

Seisaku Kanayama1, Takayuki Hara, Yusuke Hamada, Yuji Matsumaru.   

Abstract

INTRODUCTION: With the development of computed tomography (CT) and magnetic resonance imaging (MRI), the use of conventional X-ray angiography including digital subtraction angiography (DSA) for diagnosis has decreased, as it is an invasive technique with a risk of neurological complications. However, X-ray angiography imaging technologies have progressed markedly, along with the development of endovascular treatments. A newly developed angiography technique using cone-beam CT (CBCT) technology provides higher spatial resolution than conventional CT. Herein, we describe the potential of this technology for neurosurgical operations with reference to clinical cases.
METHODS: Two hundred twenty-five patients who received 80-kV high-resolution CBCT from July 2011 to June 2014 for preoperative examinations were included in this study. For pathognomonical cases, images were taken with suitable reconstruction modes and contrast protocols. Cases were compared with intraoperative findings or images from other modalities.
RESULTS: We observed the following pathognomonical types: (1) imaging of the distal dural ring (DDR) and the surrounding structure for paraclinoid aneurysms, (2) imaging of thin blood vessels, and (3) imaging of both brain tumors and their surrounding anatomy. Our devised 80-kV high-resolution CBCT imaging system provided clear visualization of detailed anatomy when compared with other modalities in almost all cases. Only two cases provided poor visualization due to movement artifact.
CONCLUSION: Eighty-kilovolt high-resolution CBCT has the potential to provide detailed anatomy for neurosurgical operations when utilizing suitable modes and contrast protocols.

Entities:  

Mesh:

Year:  2014        PMID: 25370477     DOI: 10.1007/s00234-014-1447-7

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  22 in total

1.  Identification of the carotid artery dural ring by using three-dimensional computerized tomography angiography. Technical note.

Authors:  Y Murayama; K Sakurama; K Satoh; S Nagahiro
Journal:  J Neurosurg       Date:  2001-09       Impact factor: 5.115

2.  Anatomical variations in the origin of the human ophthalmic artery with special reference to the cavernous sinus and surrounding meninges.

Authors:  Y Matsumura; M Nagashima
Journal:  Cells Tissues Organs       Date:  1999       Impact factor: 2.481

3.  Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application.

Authors:  N V Patel; M J Gounis; A K Wakhloo; N Noordhoek; J Blijd; D Babic; D Takhtani; S-K Lee; A Norbash
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

4.  Intravenous flat-detector CT angiography in acute ischemic stroke management.

Authors:  Raphaël Blanc; Silvia Pistocchi; Drazenko Babic; Bruno Bartolini; Michaël Obadia; Sonia Alamowitch; Michel Piotin
Journal:  Neuroradiology       Date:  2011-05-31       Impact factor: 2.804

5.  Utility of VasoCT in the treatment of intracranial aneurysm with flow-diverter stents.

Authors:  Osman Kizilkilic; Naci Kocer; George Emmanuel Metaxas; Drazenko Babic; Robert Homan; Civan Islak
Journal:  J Neurosurg       Date:  2012-05-04       Impact factor: 5.115

6.  Differentiation between intradural and extradural locations of juxta-dural ring aneurysms by using contrast-enhanced 3-dimensional time-of-flight magnetic resonance angiography.

Authors:  Toshiyuki Tsuboi; Koji Tokunaga; Tetsuro Shingo; Takahiko Itoh; Shinya Mandai; Kazushi Kinugasa; Isao Date
Journal:  Surg Neurol       Date:  2007-04

7.  Role of C-arm VasoCT in the use of endovascular WEB flow disruption in intracranial aneurysm treatment.

Authors:  J Caroff; C Mihalea; H Neki; D Ruijters; L Ikka; N Benachour; J Moret; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-13       Impact factor: 3.825

8.  Identification of the distal dural ring with use of fusion images with 3D-MR cisternography and MR angiography: application to paraclinoid aneurysms.

Authors:  Y Watanabe; T Nakazawa; N Yamada; M Higashi; T Hishikawa; S Miyamoto; H Naito
Journal:  AJNR Am J Neuroradiol       Date:  2009-01-15       Impact factor: 3.825

9.  Radiation dose from multidetector row CT imaging for acute stroke.

Authors:  Anisa Mnyusiwalla; Richard I Aviv; Sean P Symons
Journal:  Neuroradiology       Date:  2009-06-09       Impact factor: 2.804

10.  Variations of the superficial middle cerebral vein: classification using three-dimensional CT angiography.

Authors:  Y Suzuki; K Matsumoto
Journal:  AJNR Am J Neuroradiol       Date:  2000-05       Impact factor: 4.966

View more
  1 in total

1.  Lens dose reduction with a bismuth shield in neuro cone-beam computed tomography: an investigation on optimum shield device placement conditions.

Authors:  Satoru Kawauchi; Koichi Chida; Yusuke Hamada; Wataro Tsuruta
Journal:  Radiol Phys Technol       Date:  2021-11-18