Right coronary MR angiography at 7 T: a direct quantitative and qualitative comparison with 3 T in young healthy volunteers.

Saskia G C van Elderen1, Maarten J Versluis, Jos J M Westenberg, Harsh Agarwal, Nadine B Smith, Matthias Stuber, Albert de Roos, Andrew G Webb.   

Abstract

PURPOSE: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T.
MATERIALS AND METHODS: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age ± standard deviation, 25 years ± 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test.
RESULTS: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 ± 34 versus 52 ± 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 ± 47 versus 67 ± 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% ± 9 versus 50% ± 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference.
CONCLUSION: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T.

Entities:  

Mesh:

Year:  2010        PMID: 20851943      PMCID: PMC2941721          DOI: 10.1148/radiol.100615

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  17 in total

1.  Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions.

Authors:  S E Fischer; S A Wickline; C H Lorenz
Journal:  Magn Reson Med       Date:  1999-08       Impact factor: 4.668

2.  Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations.

Authors:  M Stuber; R M Botnar; P G Danias; K V Kissinger; W J Manning
Journal:  Radiology       Date:  1999-08       Impact factor: 11.105

3.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

4.  Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5T and 3.0T.

Authors:  Xiaoming Bi; Vibhas Deshpande; Orlando Simonetti; Gerhard Laub; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2005-08       Impact factor: 4.813

5.  Spiral magnetic resonance coronary angiography--direct comparison of 1.5 Tesla vs. 3 Tesla.

Authors:  Phillip C Yang; Patricia Nguyen; Ann Shimakawa; Jean Brittain; John Pauly; Dwight Nishimura; Bob Hu; Michael McConnell
Journal:  J Cardiovasc Magn Reson       Date:  2004       Impact factor: 5.364

6.  The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T.

Authors:  H Wen; T J Denison; R W Singerman; R S Balaban
Journal:  J Magn Reson       Date:  1997-03       Impact factor: 2.229

7.  Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography.

Authors:  Xiaoming Bi; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2005-02       Impact factor: 4.813

8.  Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease.

Authors:  Torsten Sommer; Matthias Hackenbroch; Ulrich Hofer; Alexandra Schmiedel; Winfried A Willinek; Sebastian Flacke; Jürgen Gieseke; Frank Träber; Rolf Fimmers; Harold Litt; Hans Schild
Journal:  Radiology       Date:  2005-01-21       Impact factor: 11.105

9.  Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA.

Authors:  R M Botnar; M Stuber; P G Danias; K V Kissinger; W J Manning
Journal:  Circulation       Date:  1999-06-22       Impact factor: 29.690

10.  Assessment of coronary artery disease using magnetic resonance coronary angiography: a national multicenter trial.

Authors:  Shingo Kato; Kakuya Kitagawa; Nanaka Ishida; Masaki Ishida; Motonori Nagata; Yasutaka Ichikawa; Kazuhiro Katahira; Yuji Matsumoto; Koji Seo; Reiji Ochiai; Yasuyuki Kobayashi; Hajime Sakuma
Journal:  J Am Coll Cardiol       Date:  2010-09-14       Impact factor: 24.094

View more
  16 in total

1.  Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: implications for clinical imaging.

Authors:  Lukas Winter; Peter Kellman; Wolfgang Renz; Andreas Gräßl; Fabian Hezel; Christof Thalhammer; Florian von Knobelsdorff-Brenkenhoff; Valeriy Tkachenko; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  Eur Radiol       Date:  2012-06-01       Impact factor: 5.315

2.  Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging.

Authors:  Conrad Martin; Tobias Frauenrath; Celal Ozerdem; Wolfgang Renz; Thoralf Niendorf
Journal:  Eur Radiol       Date:  2011-06-08       Impact factor: 5.315

3.  Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Hussein Rayatzadeh; Kraig V Kissinger; Beth Goddu; Lois A Goepfert; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

4.  Two-dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: design, evaluation, and application.

Authors:  Christof Thalhammer; Wolfgang Renz; Lukas Winter; Fabian Hezel; Jan Rieger; Harald Pfeiffer; Andreas Graessl; Frank Seifert; Werner Hoffmann; Florian von Knobelsdorff-Brenkenhoff; Valeriy Tkachenko; Jeanette Schulz-Menger; Peter Kellman; Thoralf Niendorf
Journal:  J Magn Reson Imaging       Date:  2012-06-15       Impact factor: 4.813

5.  Utility of respiratory-navigator-rejected k-space lines for improved signal-to-noise ratio in three-dimensional cardiac MR.

Authors:  Mehmet Akçakaya; Jaime L Shaw; Thomas H Hauser; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-12-11       Impact factor: 4.668

Review 6.  Coronary imaging techniques with emphasis on CT and MRI.

Authors:  Mathieu Lederlin; Jean-Benoit Thambo; Valérie Latrabe; Olivier Corneloup; Hubert Cochet; Michel Montaudon; François Laurent
Journal:  Pediatr Radiol       Date:  2011-11-30

7.  Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

8.  Spatially selective implementation of the adiabatic T2Prep sequence for magnetic resonance angiography of the coronary arteries.

Authors:  Sahar Soleimanifard; Michael Schär; Allison G Hays; Jerry L Prince; Robert G Weiss; Matthias Stuber
Journal:  Magn Reson Med       Date:  2012-08-22       Impact factor: 4.668

9.  Robust volume-targeted balanced steady-state free-precession coronary magnetic resonance angiography in a breathhold at 3.0 Tesla: a reproducibility study.

Authors:  Sahar Soleimanifard; Matthias Stuber; Allison G Hays; Robert G Weiss; Michael Schär
Journal:  J Cardiovasc Magn Reson       Date:  2014-04-23       Impact factor: 5.364

10.  On the subjective acceptance during cardiovascular magnetic resonance imaging at 7.0 Tesla.

Authors:  Sabrina Klix; Antje Els; Katharina Paul; Andreas Graessl; Celal Oezerdem; Oliver Weinberger; Lukas Winter; Christof Thalhammer; Till Huelnhagen; Jan Rieger; Heidrun Mehling; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  PLoS One       Date:  2015-01-26       Impact factor: 3.240

View more