Literature DB >> 22915337

Spatially selective implementation of the adiabatic T2Prep sequence for magnetic resonance angiography of the coronary arteries.

Sahar Soleimanifard1, Michael Schär, Allison G Hays, Jerry L Prince, Robert G Weiss, Matthias Stuber.   

Abstract

In coronary magnetic resonance angiography, a magnetization-preparation scheme for T2-weighting (T2Prep) is widely used to enhance contrast between the coronary blood-pool and the myocardium. This prepulse is commonly applied without spatial selection to minimize flow sensitivity, but the nonselective implementation results in a reduced magnetization of the in-flowing blood and a related penalty in signal-to-noise ratio. It is hypothesized that a spatially selective T2Prep would leave the magnetization of blood outside the T2Prep volume unaffected and thereby lower the signal-to-noise ratio penalty. To test this hypothesis, a spatially selective T2Prep was implemented where the user could freely adjust angulation and position of the T2Prep slab to avoid covering the ventricular blood-pool and saturating the in-flowing spins. A time gap of 150 ms was further added between the T2Prep and other prepulses to allow for in-flow of a larger volume of unsaturated spins. Consistent with numerical simulation, the spatially selective T2Prep increased in vivo human coronary artery signal-to-noise ratio (42.3 ± 2.9 vs. 31.4 ± 2.2, n = 22, P < 0.0001) and contrast-to-noise-ratio (18.6 ± 1.5 vs. 13.9 ± 1.2, P = 0.009) as compared to those of the nonselective T2Prep. Additionally, a segmental analysis demonstrated that the spatially selective T2Prep was most beneficial in proximal and mid segments where the in-flowing blood volume was largest compared to the distal segments.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22915337      PMCID: PMC3530637          DOI: 10.1002/mrm.24437

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography.

Authors:  M Stuber; R M Botnar; P G Danias; D K Sodickson; K V Kissinger; M Van Cauteren; J De Becker; W J Manning
Journal:  J Am Coll Cardiol       Date:  1999-08       Impact factor: 24.094

Review 2.  Coronary imaging with cardiovascular magnetic resonance: current state of the art.

Authors:  Amedeo Chiribiri; Masaki Ishida; Eike Nagel; Rene M Botnar
Journal:  Prog Cardiovasc Dis       Date:  2011 Nov-Dec       Impact factor: 8.194

3.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

4.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

5.  Coronary arteries: breath-hold MR angiography.

Authors:  R R Edelman; W J Manning; D Burstein; S Paulin
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

6.  Coronary magnetic resonance angiography for the detection of coronary stenoses.

Authors:  W Y Kim; P G Danias; M Stuber; S D Flamm; S Plein; E Nagel; S E Langerak; O M Weber; E M Pedersen; M Schmidt; R M Botnar; W J Manning
Journal:  N Engl J Med       Date:  2001-12-27       Impact factor: 91.245

7.  Coronary angiography with magnetization-prepared T2 contrast.

Authors:  J H Brittain; B S Hu; G A Wright; C H Meyer; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

8.  Flow-independent T(2)-prepared inversion recovery black-blood MR imaging.

Authors:  Chia-Ying Liu; Thorsten A Bley; Oliver Wieben; Jean H Brittain; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2010-01       Impact factor: 4.813

9.  Practical signal-to-noise ratio quantification for sensitivity encoding: application to coronary MR angiography.

Authors:  Jing Yu; Harsh Agarwal; Matthias Stuber; Michael Schär
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

10.  VESSEL CENTERLINE TRACKING AND BOUNDARY SEGMENTATION IN CORONARY MRA WITH MINIMAL MANUAL INTERACTION.

Authors:  Sahar Soleimanifard; Michael Schär; Allison G Hays; Robert G Weiss; Matthias Stuber; Jerry L Prince
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2012
View more
  3 in total

1.  Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

Authors:  Hadrien Dyvorne; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-12-01       Impact factor: 4.668

2.  Volumetric coronary endothelial function assessment: a feasibility study exploiting stack-of-stars 3D cine MRI and image-based respiratory self-gating.

Authors:  Gabriele Bonanno; Robert G Weiss; Davide Piccini; Jérôme Yerly; Sahar Soleimani; Li Pan; Xiaoming Bi; Allison G Hays; Matthias Stuber; Michael Schär
Journal:  NMR Biomed       Date:  2021-07-21       Impact factor: 4.044

3.  Single-breath-hold whole-heart coronary MRA in healthy volunteers at 3.0-T MRI.

Authors:  Yuji Iyama; Takeshi Nakaura; Masafumi Kidoh; Tetsuya Kawahara; Naritsugu Sakaino; Kazunori Harada; Tomoyuki Okuaki; Yasuyuki Yamashita
Journal:  Springerplus       Date:  2014-11-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.