Literature DB >> 16028242

Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5T and 3.0T.

Xiaoming Bi1, Vibhas Deshpande, Orlando Simonetti, Gerhard Laub, Debiao Li.   

Abstract

PURPOSE: To assess the feasibility of three-dimensional breathhold coronary magnetic resonance angiography (MRA) at 3.0T using the steady-state free precession (SSFP) sequence, and quantify the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) gains of coronary MRA from 1.5T to 3.0T using whole-body and phased-array cardiac coils as the signal receiver.
MATERIALS AND METHODS: Eight healthy volunteers were scanned on 1.5T and 3.0T whole-body systems using the SSFP sequence. Numerical simulations were performed for the SSFP sequence to optimize the flip angle and predict signal enhancement from 1.5T to 3.0T. Coronary artery images were acquired with the whole-body coil in transmit-receive mode or transmit-only with phased-array cardiac coil receivers.
RESULTS: In vivo studies of the same volunteer group at both field strengths showed increases of 87% in SNR and 83% in CNR from 1.5T to 3.0T using a whole-body coil as the signal receiver. The corresponding increases using phased-array receivers were 53% in SNR and 92% in CNR. However, image quality at 3.0T was more variable than 1.5T, with increased susceptibility artifacts and local brightening as the result of increased B(0) and B(1) inhomogeneities.
CONCLUSION: Coronary MRA at 3.0T using a three-dimensional breathhold SSFP sequence is feasible. Improved SNR at 3.0T warrants the use of coronary MRA with faster acquisition and/or improved spatial resolution. Further investigations are required to improve the consistency of image quality and signal uniformity at 3.0T. (c) 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16028242     DOI: 10.1002/jmri.20374

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  27 in total

1.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

2.  Black-blood steady-state free precession (SSFP) coronary wall MRI for cardiac allografts: a feasibility study.

Authors:  Kai Lin; Xiaoming Bi; Ying Liu; Kirsi Taimen; Biao Lu; Debiao Li; James Carr
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

3.  Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla.

Authors:  Andrew N Priest; P Martin Bansmann; Kai Müllerleile; Gerhard Adam
Journal:  Eur Radiol       Date:  2006-10-05       Impact factor: 5.315

4.  Improved coronary MR angiography using wideband steady state free precession at 3 tesla with sub-millimeter resolution.

Authors:  Hsu-Lei Lee; Ajit Shankaranarayanan; Gerald M Pohost; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

5.  Whole-heart coronary magnetic resonance angiography at 3.0T using short-TR steady-state free precession, vastly undersampled isotropic projection reconstruction.

Authors:  Jingsi Xie; Peng Lai; Himanshu Bhat; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

6.  Dynamic multidetector CT and non-contrast-enhanced MR for right adrenal vein imaging: comparison with catheter venography in adrenal venous sampling.

Authors:  Hideki Ota; Kazumasa Seiji; Masahiro Kawabata; Nozomi Satani; Kei Omata; Yoshikiyo Ono; Yoshitsugu Iwakura; Ryo Morimoto; Tomonori Matsuura; Masataka Kudo; Junya Tominaga; Fumitoshi Satoh; Sadayoshi Ito; Kei Takase
Journal:  Eur Radiol       Date:  2015-06-25       Impact factor: 5.315

7.  Utility of respiratory-navigator-rejected k-space lines for improved signal-to-noise ratio in three-dimensional cardiac MR.

Authors:  Mehmet Akçakaya; Jaime L Shaw; Thomas H Hauser; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-12-11       Impact factor: 4.668

Review 8.  Coronary imaging techniques with emphasis on CT and MRI.

Authors:  Mathieu Lederlin; Jean-Benoit Thambo; Valérie Latrabe; Olivier Corneloup; Hubert Cochet; Michel Montaudon; François Laurent
Journal:  Pediatr Radiol       Date:  2011-11-30

9.  Superparamagnetic iron oxide nanoparticle-labeled cells as an effective vehicle for tracking the GFP gene marker using magnetic resonance imaging.

Authors:  Z Zhang; N Mascheri; R Dharmakumar; Z Fan; T Paunesku; G Woloschak; D Li
Journal:  Cytotherapy       Date:  2009       Impact factor: 5.414

10.  Coronary MR imaging: effect of timing and dose of isosorbide dinitrate administration.

Authors:  Peng Hu; Michael L Chuang; Long H Ngo; Christian T Stoeck; Dana C Peters; Kraig V Kissinger; Beth Goddu; Lois A Goepfert; Warren J Manning; Reza Nezafat
Journal:  Radiology       Date:  2010-02       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.