Literature DB >> 10440961

Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions.

S E Fischer1, S A Wickline, C H Lorenz.   

Abstract

Electrocardiograph (ECG) triggered or gated magnetic resonance methods are used in many imaging applications. Therefore, a reliable trigger signal derived from to the R-wave of the ECG is essential, especially in cardiac imaging. However, currently available methods often fail mainly due to the artifacts in the ECG generated by the MR scanner itself, such as the magnetohydrodynamic effect and gradient switching noise. The purpose this study was to characterize the accuracy of selected R-wave detection algorithms in an MR environment, and to develop novel approaches to eliminate imprecise triggering. Vectorcardiograms (VCG) in 12 healthy volunteers exposed to 1.5 T magnetic field were digitized and used as a reference data set including manually corrected onsets of R-waves. To define the magnetohydrodynamic effect, the VCGs were characterized in time, frequency, and spatial domains. The selected real-time R-wave detection algorithms, and a new "target-distance" VCG-based algorithm were applied either to standard surface leads calculated from the recorded VCG or to the VCG directly. The flow related artifact was higher in amplitude than the R-wave in 28% of the investigated VCGs which yielded up to 9-16%false positive detected QRS complexes for traditional algorithms. The "target-distance" R-wave detection algorithm yielded a score of 100% for detection with 0.2% false positives and was superior to all the other selected methods. Thus, the VCG of subjects exposed to a strong magnetic field can be use to separate the magnetohydrodynamic artifact and the actual R-wave, and markedly improves the trigger accuracy in gated magnetic resonance scans. Magn Reson Med 42:361-370, 1999. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10440961     DOI: 10.1002/(sici)1522-2594(199908)42:2<361::aid-mrm18>3.0.co;2-9

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  79 in total

Review 1.  Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease.

Authors:  D J Sahn; G W Vick
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

Review 3.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

4.  Increased coronary vessel wall thickness in HIV-infected young adults.

Authors:  Khaled Z Abd-Elmoniem; Aylin B Unsal; Sarah Eshera; Jatin R Matta; Nancy Muldoon; Dorothea McAreavey; Julia B Purdy; Rohan Hazra; Colleen Hadigan; Ahmed M Gharib
Journal:  Clin Infect Dis       Date:  2014-08-25       Impact factor: 9.079

5.  Magnetic field threshold for accurate electrocardiography in the MRI environment.

Authors:  Mihaela Jekic; Yu Ding; Roger Dzwonczyk; Patrick Burns; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2010-12       Impact factor: 4.668

6.  3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

Authors:  M Hackenbroch; K Nehrke; J Gieseke; C Meyer; K Tiemann; H Litt; O Dewald; C P Naehle; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2005-04-07       Impact factor: 5.315

7.  Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

Authors:  Marcus Katoh; Harald P Kühl; Elmar Spuentrup; Claudia S A Lipke; Rolf W Günther; Arno Buecker
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

8.  Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla.

Authors:  Andrew N Priest; P Martin Bansmann; Kai Müllerleile; Gerhard Adam
Journal:  Eur Radiol       Date:  2006-10-05       Impact factor: 5.315

9.  Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease.

Authors:  Fei Han; Ziwu Zhou; Eric Han; Yu Gao; Kim-Lien Nguyen; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2016-08-16       Impact factor: 4.668

10.  A 1.5T MRI-conditional 12-lead electrocardiogram for MRI and intra-MR intervention.

Authors:  Zion Tsz Ho Tse; Charles L Dumoulin; Gari D Clifford; Jeff Schweitzer; Lei Qin; Julien Oster; Michael Jerosch-Herold; Raymond Y Kwong; Gregory Michaud; William G Stevenson; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more