Sabrina Klix1, Antje Els1, Katharina Paul1, Andreas Graessl1, Celal Oezerdem1, Oliver Weinberger1, Lukas Winter1, Christof Thalhammer1, Till Huelnhagen1, Jan Rieger1, Heidrun Mehling2, Jeanette Schulz-Menger3, Thoralf Niendorf4.
Abstract
PURPOSE: This study examines the subjective acceptance during UHF-CMR in a cohort of healthy volunteers who underwent a cardiac MR examination at 7.0T.Entities:
Mesh:
Year: 2015 PMID: 25621491 PMCID: PMC4306482 DOI: 10.1371/journal.pone.0117095
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Synopsis of the characteristics of the 7.0 T whole body MR system used.
|
| |
| magnet bore | whole-body magnet |
| magnet length without cover | 337 cm |
| scanner length including cover | 400 cm |
| inner diameter | 60 cm |
| diameter of flared opening | 120 cm |
| length of flared opening | 35 cm |
|
| |
| max. patient weight | 200 kg |
| max. range | 325 cm |
| patient table speed | (25–60) mm/s |
|
| |
| effective inner A-P diameter with patient table in the iso-center position | 40 cm |
| in bore ventilation | can be set to 3 different levels |
| in bore intercom | including loudspeaker, microphone and earphones |
Overview of the transceiver RF coil arrays (1H, f = 298 MHz) coils employed.
| RF coil design | number of RF coil elements | RF coil size head-feet x left-right (cm2) | RF coil weight (kg) | max local SAR (10g average) @ 1W input power in (W/kg) | subjects under-going an UHF-CMR examina-tion (n = 165) |
|---|---|---|---|---|---|
|
| 2 anterior and 2 posterior loop elements | 34x30 anterior 35x30 posterior | 1.8 anterior 1.7 posterior | 0.57 | 3 |
|
| 5 anterior and 3 posterior loop elements | 21x31 anterior 21x31 posterior | 2.1 anterior 1.8 posterior | 0.43 | 1 |
|
| 8 anterior and 8 posterior loop elements | 33x33 anterior 45x34 posterior | 2.1 anterior 2.7 posterior | 0.36 | 50 |
|
| 16 anterior and 16 posterior loop elements | 32x37 anterior 32x37 posterior | 1.6 anterior 1.6 posterior | 0.9 | 40 |
|
| 4 anterior and 4 posterior bow tie antennas | 15x32 anterior 15x32 posterior | 2.6 anterior 2.6 posterior | 0.6 | 26 |
|
| 8 anterior and 8 posterior bow tie antennas | 31x32 anterior 31x32 posterior | 5.3 anterior 5.3 posterior | 0.34 | 45 |
Overview of the parameters used for 2D CINE FLASH imaging of the heart at 7.0 T.
| RF coils | spatial resolution (mm3) | matrix size | FOV (mm2) | TE (ms) | TR (ms) | receiver bandwidth (Hz/pixel) | acceleration factor |
|---|---|---|---|---|---|---|---|
|
| (1.4x1.4x4) | 256x232 | 360x326 | 2.7 | 5.6 | 444 | 1–4 |
|
| (1.4x1.4x4) | 256x232 | 360x326 | 2.7 | 5.6 | 444 | 1–4 |
|
| (1.4x1.4x4) | 256x232 | 360x326 | 2.8 | 6.3 | 444 | 1–4 |
|
| (1.1x1.1x2.5) (1.4x1.4x4) (1.8x1.8x6) | 320x264 232x256 160x176 | 360x326 | 3.3 2.7 2.4 | 6.7 5.6 5.1 | 446 444 441 | 1–5 |
|
| (1.4x1.4x4) | 256x256 | 360x360 | 2.7 | 5.6 | 444 | 2 |
|
| (0.8x0.8x2.5) (1.1x1.1x2.5) (1.4x1.4x4) (1.8x1.8x6) | 380x464 260x320 208x256 170x208 | 360x326 | 2.2 2.1 1.7 1.7 | 4.8 4.6 4.2 4.0 | 445 446 444 431 | 1–6 |
Questionnaire which was completed by all subjects immediately after the completion of the UHF-CMR examination.
| # | Question | yes | no | Comments |
|---|---|---|---|---|
| 1 | Did you feel dizziness prior to the study? | |||
| 2 | Did you feel dizziness during the study? | |||
| 3 | Did you feel dizziness after the study? | |||
| 4 | Did you see light flashes? | |||
| 5 | Did you feel heating? | |||
| 6 | Did you feel cold? | |||
| 7 | Did you feel unease? | |||
| 8 | Did you recognize muscular contraction? | |||
| 9 | Have you perceived a metallic taste? | |||
| 10 | Have you noticed other side effects? |
Overview of subject (n = 165) characteristics.
| total | female | male | |
|---|---|---|---|
|
| 165 | 41 | 124 |
|
| 36 ± 12 | 33 ± 11 | 37 ± 12 |
| age range min | 23 | 25 | 23 |
| age range max | 72 | 67 | 72 |
|
| 176 ± 9 | 167 ± 7 | 179 ± 7 |
| height range min (cm) | 158 | 158 | 165 |
| height range max (cm) | 196 | 183 | 196 |
|
| 72.9 ± 11.8 | 63 ± 7.3 | 76.2 ± 11.1 |
| weight range min (kg) | 47.6 | 47.6 | 60.5 |
| weight range max (kg) | 114.0 | 83 | 114.0 |
|
| 23.6 ± 3.3 | 22.7 ± 2.7 | 23.9 ± 3.5 |
| BMI range min (kg/m2) | 16.9 | 18.5 | 16.9 |
| BMI range max (kg/m2) | 33.5 | 32 | 33.5 |
|
| 127/79 ± 14/11 | 123/76 ±14/10 | 129/80 ± 14/12 |
| blood pressure range min (mmHg) | 96/55 | 96/55 | 100/55 |
| blood pressure range min (mmHg) | 180/119 | 166/111 | 180/119 |
|
| 892 ± 149 | 833 ± 136 | 912 ± 148 |
| RR-interval range min (ms) | 522 | 618 | 522 |
| RR-interval range max (ms) | 1277 | 1071 | 1277 |
|
| 69 ± 12 | 74 ± 12 | 68 ± 12 |
| heart rate range min (bpm) | 47 | 56 | 47 |
| heart rate range max (bpm) | 115 | 97 | 115 |
|
| 945 ± 106 | 827 ± 78 | 985 ± 82 |
| RR-interval range min (ms) | 657 | 657 | 726 |
| RR-interval range max (ms) | 1296 | 1077 | 1296 |
|
| 64 ± 7 | 73 ± 7 | 61 ± 5 |
| heart rate range min (bpm) | 46 | 55 | 46 |
| heart rate range max (bpm) | 91 | 91 | 82 |
|
| 36.4 ± 0.5 | 36.6 ± 0.4 | 36.3 ± 0.5 |
| temperature range min (°C) | 34.5 | 35.6 | 34.5 |
| temperature range max (°C) | 37.6 | 37.5 | 37.6 |
|
| 64 ± 27 | 63 ± 17 | 65± 27 |
| examination time min (min) | 34 | 45 | 34 |
| examination time max (min) | 124 | 85 | 124 |
Figure 1Synopsis of RF coil configurations used in this study.
Top: Photographs of the cardiac optimized 7.0 T transceiver RF coil arrays to illustrate the coil design and the coil geometry together with the coil positioning used in the UHF-CMR setting. The RF coils employed include a four channel [40], an eight channel [41], a 16 channel [9,42] and a 32 channel loop coil [43] configuration and an eight channel [44] and 16 channel bow tie antenna array configuration [45]. Bottom: Short axis views of the heart derived from 2D CINE FLASH acquisitions using the RF coil configurations in the top row and a spatial resolution of (1.4 x 1.4 x 4) mm3 and parallel imaging (R = 2, GRAPPA reconstruction).
Figure 2Results derived from the completed questionnaires.
Synopsis of the results reported by 165 subjects on subjective acceptance of UHF-CMR. The most mentioned side effects reported were transient muscular contraction during scanning (12.7%) and dizziness experienced during the study (12.7%).
Figure 3Gender distribution of reasons of discomfort. Synopsis of reasons of discomfort reported by female and male subjects who underwent an UHF-CMR examination.
Summary of other side effects revealed by the question: “Have you noticed other side effects”.
| other side effects (in response to question 10) | total | female | male |
|---|---|---|---|
| arm fell asleep | 1 | - | 1 |
| cough | 2 | - | 2 |
| dry lips | 1 | - | 1 |
| dry mouth | 7 | 1 | 6 |
| feeling of a caressing on stomach | 1 | - | 1 |
| feet and thighs fell asleep | 1 | - | 1 |
| back pain from lying down with projection into the kidney region | 1 | 1 | - |
| pain in the left ear | 1 | 1 | - |
| seeing shadows | 1 | - | 1 |
| sensory illusions | 1 | - | 1 |
| sensory loss in hip joints | 1 | - | 1 |
| stiff neck | 1 | 1 | - |
| sweating attacks | 1 | - | 1 |
| tingling in both arms | 1 | 1 | - |
| tingling on the forehead | 1 | - | 1 |
| tiredness | 1 | 1 | - |
| vibration at the hip | 1 | - | 1 |