Literature DB >> 20593428

Improved renal perfusion measurement with a dual navigator-gated Q2TIPS fair technique.

Ruitian Song1, Ralf B Loeffler, Claudia M Hillenbrand.   

Abstract

A dual navigator-gated, flow-sensitive alternating inversion recovery (FAIR) true fast imaging with steady precession (True-FISP) sequence has been developed for accurate quantification of renal perfusion. FAIR methods typically overestimate renal perfusion when respiratory motion causes the inversion slice to move away from the imaging slice, which then incorporates unlabeled spins from static tissue. To overcome this issue, the dual navigator scheme was introduced to track inversion and imaging slices, and thus to ensure the same position for both slices. Accuracy was further improved by a well-defined bolus length, which was achieved by a modification version of Q2TIPS (quantitative imaging of perfusion using a single subtraction, second version with interleaved thin-slice TI(1) periodic saturation): a series of saturation pulses was applied to both sides of the imaging slice at a certain time after the inversion. The dual navigator-gated technique was tested in eight volunteers. The measured renal cortex perfusion rates were between 191 and 378 mL/100 g/min in the renal cortex with a mean of 376 mL/100 g/min. The proposed technique may prove most beneficial for noncontrast-based renal perfusion quantification in young children and patients who may have difficulty holding their breath for prolonged periods or are sedated/anesthetized.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20593428      PMCID: PMC2955188          DOI: 10.1002/mrm.22532

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Human cardiac imaging at 3 T using phased array coils.

Authors:  R Noeske; F Seifert; K H Rhein; H Rinneberg
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

2.  Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE.

Authors:  N Karger; J Biederer; S Lüsse; J Grimm; J Steffens; M Heller; C Glüer
Journal:  Magn Reson Imaging       Date:  2000-07       Impact factor: 2.546

3.  Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses.

Authors:  David Alberg Holm; Karam Sidaros
Journal:  Magn Reson Imaging       Date:  2006-09-25       Impact factor: 2.546

4.  Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx.

Authors:  Ze Wang; Geoffrey K Aguirre; Hengyi Rao; Jiongjiong Wang; María A Fernández-Seara; Anna R Childress; John A Detre
Journal:  Magn Reson Imaging       Date:  2007-09-10       Impact factor: 2.546

5.  Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping.

Authors:  S G Kim
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

6.  Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system.

Authors:  G S Payne; M O Leach
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

7.  Mechanism of NSF: New evidence challenging the prevailing theory.

Authors:  Ben B Newton; Sergio A Jimenez
Journal:  J Magn Reson Imaging       Date:  2009-12       Impact factor: 4.813

8.  Water content and NMR relaxation time gradients in the rabbit kidney.

Authors:  H L Kundel; B Schlakman; P M Joseph; J E Fishman; R Summers
Journal:  Invest Radiol       Date:  1986-01       Impact factor: 6.016

9.  Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labeling.

Authors:  Philip M Robson; Ananth J Madhuranthakam; Weiying Dai; Ivan Pedrosa; Neil M Rofsky; David C Alsop
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

10.  Renal perfusion in humans: MR imaging with spin tagging of arterial water.

Authors:  D A Roberts; J A Detre; L Bolinger; E K Insko; R E Lenkinski; M J Pentecost; J S Leigh
Journal:  Radiology       Date:  1995-07       Impact factor: 11.105

View more
  13 in total

1.  Repeatability of renal arterial spin labelling MRI in healthy subjects.

Authors:  Marica Cutajar; David L Thomas; Tina Banks; Christopher A Clark; Xavier Golay; Isky Gordon
Journal:  MAGMA       Date:  2012-01-13       Impact factor: 2.310

2.  QUIPSS II with window-sliding saturation sequence (Q2WISE).

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

3.  Evaluation of respiratory liver and kidney movements for MRI navigator gating.

Authors:  Ruitian Song; Aaryani Tipirneni; Perry Johnson; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  J Magn Reson Imaging       Date:  2011-01       Impact factor: 4.813

4.  Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys.

Authors:  Hao Song; Dan Ruan; Wenyang Liu; V Andrew Stenger; Rolf Pohmann; Maria A Fernández-Seara; Tejas Nair; Sungkyu Jung; Jingqin Luo; Yuichi Motai; Jingfei Ma; John D Hazle; H Michael Gach
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

5.  Sensitivity of arterial spin labeling perfusion MRI to pharmacologically induced perfusion changes in rat kidneys.

Authors:  Huan Tan; Jon Thacker; Tammy Franklin; Pottumarthi V Prasad
Journal:  J Magn Reson Imaging       Date:  2014-05-06       Impact factor: 4.813

6.  Combined renal MRA and perfusion with a single dose of contrast.

Authors:  Parmede Vakil; James C Carr; Timothy J Carroll
Journal:  Magn Reson Imaging       Date:  2012-04-20       Impact factor: 2.546

7.  Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling.

Authors:  Huan Tan; Ioannis Koktzoglou; Pottumarthi V Prasad
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

Review 8.  Functional MRI of the kidneys.

Authors:  Jeff L Zhang; Henry Rusinek; Hersh Chandarana; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2013-02       Impact factor: 4.813

9.  Evaluation of renal blood flow using multi-phase echo-planar magnetic resonance imaging and signal targeting with alternating radiofrequency (EPISTAR) in 3-T magnetic resonance imaging.

Authors:  Hiroyuki Sugimori; Mitsuhiro Nakanishi; Noriyuki Fujima; Kinya Ishizaka; Suzuko Mito; Hiroyuki Hamaguchi; Motomichi Sakata
Journal:  Radiol Phys Technol       Date:  2012-08-07

10.  Quantitative renal perfusion measurements in a rat model of acute kidney injury at 3T: testing inter- and intramethodical significance of ASL and DCE-MRI.

Authors:  Fabian Zimmer; Frank G Zöllner; Simone Hoeger; Sarah Klotz; Charalambos Tsagogiorgas; Bernhard K Krämer; Lothar R Schad
Journal:  PLoS One       Date:  2013-01-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.