Literature DB >> 9358458

Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system.

G S Payne1, M O Leach.   

Abstract

FOCI pulses are a variant of hyperbolic secant pulses in which the RF amplitude, RF frequency, and gradient waveform are all modulated by the same function A(t). This increases the usable gradient amplitude without requiring a corresponding increase in RF amplitude. In this paper the implementation and inversion profiles of FOCI pulses on a clinical MR system are described, showing improved slice definition and chemical-shift offset behavior. Their adiabatic behavior is confirmed, and their use with an ISIS sequence for localized MRS is illustrated. Finally the effects of waveform digitization are considered, and the implications for SAR and dB/dt are discussed.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9358458     DOI: 10.1002/mrm.1910380520

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  QUIPSS II with window-sliding saturation sequence (Q2WISE).

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

2.  Single-Shot Coronary Quiescent-Interval Slice-Selective Magnetic Resonance Angiography Using Compressed Sensing: A Feasibility Study in Patients With Congenital Heart Disease.

Authors:  Daming Shen; Robert R Edelman; Joshua D Robinson; Hassan Haji-Valizadeh; Marci Messina; Shivraman Giri; Ioannis Koktzoglou; Cynthia K Rigsby; Daniel Kim
Journal:  J Comput Assist Tomogr       Date:  2018 Sep/Oct       Impact factor: 1.826

3.  Advanced single voxel 1 H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations.

Authors:  Gülin Öz; Dinesh K Deelchand; Jannie P Wijnen; Vladimír Mlynárik; Lijing Xin; Ralf Mekle; Ralph Noeske; Tom W J Scheenen; Ivan Tkáč
Journal:  NMR Biomed       Date:  2020-01-10       Impact factor: 4.044

4.  Ungated radial quiescent-inflow single-shot (UnQISS) magnetic resonance angiography using optimized azimuthal equidistant projections.

Authors:  Robert R Edelman; Shivraman Giri; Ian G Murphy; Oisin Flanagan; Peter Speier; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2014-09-24       Impact factor: 4.668

5.  Improved renal perfusion measurement with a dual navigator-gated Q2TIPS fair technique.

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

6.  Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging.

Authors:  Weiying Dai; Philip M Robson; Ajit Shankaranarayanan; David C Alsop
Journal:  Magn Reson Med       Date:  2011-11-14       Impact factor: 4.668

7.  Investigating white matter perfusion using optimal sampling strategy arterial spin labeling at 7 Tesla.

Authors:  Alexander G Gardener; Peter Jezzard
Journal:  Magn Reson Med       Date:  2014-06-20       Impact factor: 4.668

8.  Single-shot single-voxel lactate measurements using FOCI-LASER and a multiple-quantum filter.

Authors:  Geoffrey S Payne; Nandita M deSouza; Christina Messiou; Martin O Leach
Journal:  NMR Biomed       Date:  2015-04       Impact factor: 4.044

9.  Validating a robust double-quantum-filtered (1) H MRS lactate measurement method in high-grade brain tumours.

Authors:  G S Payne; L M Harris; G S Cairns; C Messiou; N M deSouza; A Macdonald; F Saran; M O Leach
Journal:  NMR Biomed       Date:  2016-08-11       Impact factor: 4.044

10.  Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla.

Authors:  Robert R Edelman; S Giri; A Pursnani; M P F Botelho; W Li; I Koktzoglou
Journal:  J Cardiovasc Magn Reson       Date:  2015-11-23       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.