Literature DB >> 17071344

Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses.

David Alberg Holm1, Karam Sidaros.   

Abstract

OBJECTIVE: An important source of error in arterial spin labeling (ASL) is incomplete static tissue subtraction due to imperfect slice profiles. This effect can be reduced by saturating the spins in the imaging area prior to labeling. In this study, the use of optimized presaturation is compared with the use of optimized RF pulses for minimizing this error.
MATERIALS AND METHODS: Different methods for optimizing presaturation were simulated by numerical solution of the Bloch equation. Presaturation was optimized by changing the number of presaturation pulses, their position in the pulse sequence and the area of the crusher gradients following each saturation pulse. It was also investigated whether the use of optimized presaturation could reduce the tag gap needed to ensure complete static tissue subtraction. Simulation results were verified using phantom and in vivo studies at 3T.
RESULTS: In proximal inversion with control for off-resonance effects, optimized presaturation could reduce the necessary tag gap to 15% of the imaging slab for experiments using standard RF pulses, while c-FOCI RF pulses could reduce it to 11%. In flow-sensitive alternating inversion recovery, a single presaturation pulse could reduce the inversion width to 122% of the imaging slab and neither multiple presaturation pulses nor optimized RF pulses could reduce it further.
CONCLUSION: Optimized presaturation can reduce the necessary inversion width to the same level as if using optimized RF pulses and can, therefore, be used to optimize ASL sensitivity. Furthermore, optimized presaturation can reduce the B(1)-dependent sensitivity in static tissue subtraction.

Entities:  

Mesh:

Year:  2006        PMID: 17071344     DOI: 10.1016/j.mri.2006.07.011

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Influence of selecting EPI readout-encoding bandwidths on arterial spin labeling perfusion MRI.

Authors:  Geon-Ho Jahng; Norbert Schuff
Journal:  MAGMA       Date:  2009-07-04       Impact factor: 2.310

2.  Improved renal perfusion measurement with a dual navigator-gated Q2TIPS fair technique.

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

3.  Investigating white matter perfusion using optimal sampling strategy arterial spin labeling at 7 Tesla.

Authors:  Alexander G Gardener; Peter Jezzard
Journal:  Magn Reson Med       Date:  2014-06-20       Impact factor: 4.668

4.  Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T.

Authors:  Benjamin E Northrup; Kyle S McCommis; Haosen Zhang; Shuddhadeb Ray; Pamela K Woodard; Robert J Gropler; Jie Zheng
Journal:  J Cardiovasc Magn Reson       Date:  2008-11-17       Impact factor: 5.364

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.