Literature DB >> 19319891

Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labeling.

Philip M Robson1, Ananth J Madhuranthakam, Weiying Dai, Ivan Pedrosa, Neil M Rofsky, David C Alsop.   

Abstract

Arterial spin labeling (ASL) perfusion measurements may have many applications outside the brain. In the abdomen, severe image artifacts can arise from motions between acquisitions of multiple signal averages in ASL, even with single-shot image acquisition. Background suppression and respiratory motion synchronization techniques can be used to ameliorate these artifacts. Two separate in vivo studies of renal perfusion imaging using pulsed continuous ASL (pCASL) were performed. The first study assessed various combinations of background suppression and breathing strategies. The second investigated the retrospective sorting of images acquired during free breathing based on respiratory position. Quantitative assessments of the test-retest repeatability of perfusion measurements and the image quality scored by two radiologists were made. Image quality was most significantly improved by using background suppression schemes and controlled breathing when compared to other combinations without background suppression or with free breathing, assessed by test-retests (5% level, F-test), and by radiologists' scores (5% level, Mann-Whitney U-test). Under free breathing, retrospectively sorting images based on respiratory position showed significant improvement. Both radiologists found 100% of the images had preferable image sharpness after sorting. High-quality renal perfusion measurements with reduced respiratory motion artifacts have been demonstrated using ASL when appropriate background suppression and breathing strategies are applied.

Entities:  

Mesh:

Year:  2009        PMID: 19319891      PMCID: PMC2946256          DOI: 10.1002/mrm.21960

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  56 in total

1.  Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE.

Authors:  N Karger; J Biederer; S Lüsse; J Grimm; J Steffens; M Heller; C Glüer
Journal:  Magn Reson Imaging       Date:  2000-07       Impact factor: 2.546

2.  Simultaneous magnetic resonance gadolinium-enhanced 2D perfusion and 3D angiographic imaging.

Authors:  James W Goldfarb; Pottumarthi V Prasad; Q Chen; Robert R Edelman
Journal:  Magn Reson Imaging       Date:  2003-07       Impact factor: 2.546

3.  Morphological, contrast-enhanced and spin labeling perfusion imaging for monitoring of relapse after RF ablation of renal cell carcinomas.

Authors:  Andreas Boss; Petros Martirosian; Christina Schraml; Stephan Clasen; Michael Fenchel; Artistotelis Anastasiadis; Claus D Claussen; Philippe L Pereira; Fritz Schick
Journal:  Eur Radiol       Date:  2006-01-27       Impact factor: 5.315

4.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.

Authors:  K K Kwong; J W Belliveau; D A Chesler; I E Goldberg; R M Weisskoff; B P Poncelet; D N Kennedy; B E Hoppel; M S Cohen; R Turner
Journal:  Proc Natl Acad Sci U S A       Date:  1992-06-15       Impact factor: 11.205

5.  Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping.

Authors:  S G Kim
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

6.  Blood flow patterns in the human aorta studied by magnetic resonance.

Authors:  R H Klipstein; D N Firmin; S R Underwood; R S Rees; D B Longmore
Journal:  Br Heart J       Date:  1987-10

7.  Measurement of aortic blood flow with MR imaging: comparative study with Doppler US.

Authors:  T Matsuda; K Shimizu; T Sakurai; A Fujita; H Ohara; S Okamura; S Hashimoto; S Tamaki; C Kawai
Journal:  Radiology       Date:  1987-03       Impact factor: 11.105

8.  A monitoring, feedback, and triggering system for reproducible breath-hold MR imaging.

Authors:  Y L Liu; S J Riederer; P J Rossman; R C Grimm; J P Debbins; R L Ehman
Journal:  Magn Reson Med       Date:  1993-10       Impact factor: 4.668

9.  Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.

Authors:  R R Edelman; B Siewert; D G Darby; V Thangaraj; A C Nobre; M M Mesulam; S Warach
Journal:  Radiology       Date:  1994-08       Impact factor: 11.105

10.  Magnetic resonance imaging-measured blood flow change after antiangiogenic therapy with PTK787/ZK 222584 correlates with clinical outcome in metastatic renal cell carcinoma.

Authors:  Cedric de Bazelaire; David C Alsop; Daniel George; Ivan Pedrosa; Yongyu Wang; M Dror Michaelson; Neil M Rofsky
Journal:  Clin Cancer Res       Date:  2008-09-01       Impact factor: 12.531

View more
  38 in total

1.  Repeatability of renal arterial spin labelling MRI in healthy subjects.

Authors:  Marica Cutajar; David L Thomas; Tina Banks; Christopher A Clark; Xavier Golay; Isky Gordon
Journal:  MAGMA       Date:  2012-01-13       Impact factor: 2.310

Review 2.  Noncontrast functional MRI of the kidneys.

Authors:  Lorenzo Mannelli; Jeffrey H Maki; Sherif F Osman; Hersh Chandarana; David J Lomas; William P Shuman; Ken F Linnau; Douglas E Green; Giacomo Laffi; Miriam Moshiri
Journal:  Curr Urol Rep       Date:  2012-02       Impact factor: 3.092

3.  Robust pCASL perfusion imaging using a 3D Cartesian acquisition with spiral profile reordering (CASPR).

Authors:  Joshua S Greer; Xinzeng Wang; Yiming Wang; Marco C Pinho; Joseph A Maldjian; Ivan Pedrosa; Ananth J Madhuranthakam
Journal:  Magn Reson Med       Date:  2019-06-23       Impact factor: 4.668

4.  7T bone perfusion imaging of the knee using arterial spin labeling MRI.

Authors:  Xiufeng Li; Casey P Johnson; Jutta Ellermann
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

5.  Enabling free-breathing background suppressed renal pCASL using fat imaging and retrospective motion correction.

Authors:  Isabell K Bones; Anita A Harteveld; Suzanne L Franklin; Matthias J P van Osch; Jeroen Hendrikse; Chrit T W Moonen; Clemens Bos; Marijn van Stralen
Journal:  Magn Reson Med       Date:  2019-03-18       Impact factor: 4.668

6.  Improved renal perfusion measurement with a dual navigator-gated Q2TIPS fair technique.

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

Review 7.  Quantitative Methods in Abdominal MRI: Perfusion Imaging.

Authors:  Ananth J Madhuranthakam; Qing Yuan; Ivan Pedrosa
Journal:  Top Magn Reson Imaging       Date:  2017-12

8.  An MRI-compatible platform for one-dimensional motion management studies in MRI.

Authors:  Joris Nofiele; Qing Yuan; Mohammad Kazem; Ken Tatebe; Quinn Torres; Amit Sawant; Ivan Pedrosa; Rajiv Chopra
Journal:  Magn Reson Med       Date:  2015-10-23       Impact factor: 4.668

9.  Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling.

Authors:  Huan Tan; Ioannis Koktzoglou; Pottumarthi V Prasad
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Intratumor Heterogeneity of Perfusion and Diffusion in Clear-Cell Renal Cell Carcinoma: Correlation With Tumor Cellularity.

Authors:  Qing Yuan; Payal Kapur; Yue Zhang; Yin Xi; Ingrid Carvo; Sabina Signoretti; Ivan E Dimitrov; Jeffrey A Cadeddu; Vitaly Margulis; James Brugarolas; Ananth J Madhuranthakam; Ivan Pedrosa
Journal:  Clin Genitourin Cancer       Date:  2016-04-22       Impact factor: 2.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.