Literature DB >> 10930773

Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE.

N Karger1, J Biederer, S Lüsse, J Grimm, J Steffens, M Heller, C Glüer.   

Abstract

Quantitative perfusion imaging of human kidneys was performed using arterial spin labeling MRI with a fast spin echo readout-sequence. Perfusion maps of centrally located single slices were obtained in axial and coronal orientations. In ten healthy volunteers, the mean value of perfusion was 213+/-55 mL/(100g min) with a range from 140 to 319 mL/(100g min). These results are in accordance with literature data, considering the fact that FAIR only measures the perfusion component normal to the imaging plane. Intra-individual reproducibility errors of +/-11% were smaller than the natural interindividual variability of renal perfusion (SD = +/- 25%). Perfusion in the cortex was approximately 3-4 times higher compared to the medulla. Considering the relatively high resolution of 2x2x10 mm3, the ability to quantify perfusion, and the lack of ionizing radiation and contrast media, this technique should prove useful in diagnosing renal pathologies that are associated with reductions in tissue perfusion.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10930773     DOI: 10.1016/s0730-725x(00)00155-7

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  34 in total

1.  Repeatability of renal arterial spin labelling MRI in healthy subjects.

Authors:  Marica Cutajar; David L Thomas; Tina Banks; Christopher A Clark; Xavier Golay; Isky Gordon
Journal:  MAGMA       Date:  2012-01-13       Impact factor: 2.310

Review 2.  Magnetic resonance perfusion imaging without contrast media.

Authors:  Petros Martirosian; Andreas Boss; Christina Schraml; Nina F Schwenzer; Hansjörg Graf; Claus D Claussen; Fritz Schick
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

3.  Quantitative MRI of kidneys in renal disease.

Authors:  Timothy L Kline; Marie E Edwards; Ishan Garg; Maria V Irazabal; Panagiotis Korfiatis; Peter C Harris; Bernard F King; Vicente E Torres; Sudhakar K Venkatesh; Bradley J Erickson
Journal:  Abdom Radiol (NY)       Date:  2018-03

4.  Improved renal perfusion measurement with a dual navigator-gated Q2TIPS fair technique.

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

5.  Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

Authors:  Marica Cutajar; David L Thomas; Patrick W Hales; T Banks; Christopher A Clark; Isky Gordon
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

6.  Arterial spin labelling MRI to measure renal perfusion: a systematic review and statement paper.

Authors:  Aghogho Odudu; Fabio Nery; Anita A Harteveld; Roger G Evans; Douglas Pendse; Charlotte E Buchanan; Susan T Francis; María A Fernández-Seara
Journal:  Nephrol Dial Transplant       Date:  2018-09-01       Impact factor: 5.992

7.  Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys.

Authors:  Hao Song; Dan Ruan; Wenyang Liu; V Andrew Stenger; Rolf Pohmann; Maria A Fernández-Seara; Tejas Nair; Sungkyu Jung; Jingqin Luo; Yuichi Motai; Jingfei Ma; John D Hazle; H Michael Gach
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

8.  Consistency of Multiple Renal Functional MRI Measurements Over 18 Months.

Authors:  Lu-Ping Li; Jon Thacker; Wei Li; Huan Tan; Chi Wang; Orly Kohn; Stuart Sprague; Pottumarthi Prasad
Journal:  J Magn Reson Imaging       Date:  2018-03-08       Impact factor: 4.813

9.  Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling.

Authors:  Huan Tan; Ioannis Koktzoglou; Pottumarthi V Prasad
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results.

Authors:  Rotem S Lanzman; Hans-Jörg Wittsack; Petros Martirosian; Panagiota Zgoura; Philip Bilk; Patric Kröpil; Fritz Schick; Adina Voiculescu; Dirk Blondin
Journal:  Eur Radiol       Date:  2009-12-01       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.