Literature DB >> 8916022

High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.

L Ostergaard1, R M Weisskoff, D A Chesler, C Gyldensted, B R Rosen.   

Abstract

The authors review the theoretical basis of determination of cerebral blood flow (CBF) using dynamic measurements of nondiffusible contrast agents, and demonstrate how parametric and nonparametric deconvolution techniques can be modified for the special requirements of CBF determination using dynamic MRI. Using Monte Carlo modeling, the use of simple, analytical residue models is shown to introduce large errors in flow estimates when actual, underlying vascular characteristics are not sufficiently described by the chosen function. The determination of the shape of the residue function on a regional basis is shown to be possible only at high signal-to-noise ratio. Comparison of several nonparametric deconvolution techniques showed that a nonparametric deconvolution technique (singular value decomposition) allows estimation of flow relatively independent of underlying vascular structure and volume even at low signal-to-noise ratio associated with pixel-by-pixel deconvolution.

Mesh:

Year:  1996        PMID: 8916022     DOI: 10.1002/mrm.1910360510

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  398 in total

1.  Absolute cerebral blood flow measured by dynamic susceptibility contrast MRI: a direct comparison with Xe-133 SPECT.

Authors:  R Wirestam; E Ryding; A Lindgren; B Geijer; S Holtås; F Ståhlberg
Journal:  MAGMA       Date:  2000-12       Impact factor: 2.310

Review 2.  Echo planar imaging's impact on modern diagnostic MR-imaging: general principles and historic facts.

Authors:  M K Stehling; L Liu
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

3.  Quantitative measurements of cerebral metabolic rate of oxygen utilization using MRI: a volunteer study.

Authors:  H An; W Lin; A Celik; Y Z Lee
Journal:  NMR Biomed       Date:  2001 Nov-Dec       Impact factor: 4.044

4.  Stripe-like increase of rCBV beyond the visible border of glioblastomas: site of tumor infiltration growing after neurosurgery.

Authors:  Stella Blasel; Kea Franz; Hanns Ackermann; Stefan Weidauer; Friedhelm Zanella; Elke Hattingen
Journal:  J Neurooncol       Date:  2010-10-07       Impact factor: 4.130

5.  Investigating tumor perfusion and metabolism using multiple hyperpolarized (13)C compounds: HP001, pyruvate and urea.

Authors:  Cornelius von Morze; Peder E Z Larson; Simon Hu; Hikari A I Yoshihara; Robert A Bok; Andrei Goga; Jan Henrik Ardenkjaer-Larsen; Daniel B Vigneron
Journal:  Magn Reson Imaging       Date:  2011-12-12       Impact factor: 2.546

6.  New similarity search based glioma grading.

Authors:  Katrin Haegler; Martin Wiesmann; Christian Böhm; Jessica Freiherr; Oliver Schnell; Hartmut Brückmann; Jörg-Christian Tonn; Jennifer Linn
Journal:  Neuroradiology       Date:  2011-12-14       Impact factor: 2.804

7.  Noninvasive Measurements of Cerebral Blood Flow, Oxygen Extraction Fraction, and Oxygen Metabolic Index in Human with Inhalation of Air and Carbogen using Magnetic Resonance Imaging.

Authors:  Hongyu An; Souvik Sen; Yasheng Chen; William J Powers; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-28       Impact factor: 6.829

8.  Assessment of ischemic penumbra in patients with hyperacute stroke using amide proton transfer (APT) chemical exchange saturation transfer (CEST) MRI.

Authors:  Anna Tietze; Jakob Blicher; Irene Klaerke Mikkelsen; Leif Østergaard; Megan K Strother; Seth A Smith; Manus J Donahue
Journal:  NMR Biomed       Date:  2013-11-28       Impact factor: 4.044

9.  High-resolution longitudinal assessment of flow and permeability in mouse glioma vasculature: Sequential small molecule and SPIO dynamic contrast agent MRI.

Authors:  M M Pike; C N Stoops; C P Langford; N S Akella; L B Nabors; G Y Gillespie
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

10.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.