Literature DB >> 18812650

High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Shuai Leng1, Jie Tang, Joseph Zambelli, Brian Nett, Ranjini Tolakanahalli, Guang-Hong Chen.   

Abstract

Cone-beam computed tomography (CBCT) has been clinically used to verify patient position and to localize the target of treatment in image-guided radiation therapy (IGRT). However, when the chest and the upper abdomen are scanned, respiratory-induced motion blurring limits the utility of CBCT. In order to mitigate this blurring, respiratory-gated CBCT, i.e. 4D CBCT, was introduced. In 4D CBCT, the cone-beam projection data sets acquired during a gantry rotation are sorted into several respiratory phases. In these gated reconstructions, the number of projections for each respiratory phase is significantly reduced. Consequently, undersampling streaking artifacts are present in the reconstructed images, and the image contrast resolution is also significantly compromised. In this paper, we present a new method to simultaneously achieve both high temporal resolution ( approximately 100 ms) and streaking artifact-free image volumes in 4D CBCT. The enabling technique is a newly proposed image reconstruction method, i.e. prior image constrained compressed sensing (PICCS), which enables accurate image reconstruction using vastly undersampled cone-beam projections and a fully sampled prior image. Using PICCS, a streak-free image can be reconstructed from 10-20 cone-beam projections while the signal-to-noise ratio is determined by a denoising feature of the selected objective function and by the prior image, which is reconstructed using all of the acquired cone-beam projections. This feature of PICCS breaks the connection between the temporal resolution and streaking artifacts' level in 4D CBCT. Numerical simulations and experimental phantom studies have been conducted to validate the method.

Entities:  

Mesh:

Year:  2008        PMID: 18812650      PMCID: PMC2664532          DOI: 10.1088/0031-9155/53/20/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  Tomotherapy.

Authors:  T R Mackie; J Balog; K Ruchala; D Shepard; S Aldridge; E Fitchard; P Reckwerdt; G Olivera; T McNutt; M Mehta
Journal:  Semin Radiat Oncol       Date:  1999-01       Impact factor: 5.934

2.  Flat-panel cone-beam computed tomography for image-guided radiation therapy.

Authors:  David A Jaffray; Jeffrey H Siewerdsen; John W Wong; Alvaro A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-08-01       Impact factor: 7.038

3.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

4.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.

Authors:  Tianfang Li; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-29       Impact factor: 7.038

5.  Linac-integrated 4D cone beam CT: first experimental results.

Authors:  Lars Dietrich; Siri Jetter; Thomas Tücking; Simeon Nill; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

6.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  Enhanced 4D cone-beam CT with inter-phase motion model.

Authors:  Tianfang Li; Albert Koong; Lei Xing
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

8.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.

Authors:  Jun Lu; Thomas M Guerrero; Peter Munro; Andrew Jeung; Pai-Chun M Chi; Peter Balter; X Ronald Zhu; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

9.  Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer.

Authors:  E C Ford; J Chang; K Mueller; K Sidhu; D Todor; G Mageras; E Yorke; C C Ling; H Amols
Journal:  Med Phys       Date:  2002-12       Impact factor: 4.071

10.  Streaking artifacts reduction in four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Joseph Zambelli; Ranjini Tolakanahalli; Brian Nett; Peter Munro; Joshua Star-Lack; Bhudatt Paliwal; Guang-Hong Chen
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

View more
  45 in total

1.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  4D Cone-beam CT reconstruction using a motion model based on principal component analysis.

Authors:  David Staub; Alen Docef; Robert S Brock; Constantin Vaman; Martin J Murphy
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Authors:  Kihwan Choi; Jing Wang; Lei Zhu; Tae-Suk Suh; Stephen Boyd; Lei Xing
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

5.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

6.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

7.  Image reconstruction for sparse-view CT and interior CT-introduction to compressed sensing and differentiated backprojection.

Authors:  Hiroyuki Kudo; Taizo Suzuki; Essam A Rashed
Journal:  Quant Imaging Med Surg       Date:  2013-06

8.  Temporal resolution improvement using PICCS in MDCT cardiac imaging.

Authors:  Guang-Hong Chen; Jie Tang; Jiang Hsieh
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

9.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

10.  Cine cone beam CT reconstruction using low-rank matrix factorization: algorithm and a proof-of-principle study.

Authors:  Jian-Feng Cai; Xun Jia; Hao Gao; Steve B Jiang; Zuowei Shen; Hongkai Zhao
Journal:  IEEE Trans Med Imaging       Date:  2014-04-21       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.