Literature DB >> 20099332

Dual inversion recovery, ultrashort echo time (DIR UTE) imaging: creating high contrast for short-T(2) species.

Jiang Du1, Atsushi M Takahashi, Won C Bae, Christine B Chung, Graeme M Bydder.   

Abstract

Imaging of short-T(2) species requires not only a short echo time but also efficient suppression of long-T(2) species in order to maximize the short-T(2) contrast and dynamic range. This paper introduces a method of long-T(2) suppression using two long adiabatic inversion pulses. The first adiabatic inversion pulse inverts the magnetization of long-T(2) water and the second one inverts that of fat. Short-T(2) species experience a significant transverse relaxation during the long adiabatic inversion process and are minimally affected by the inversion pulses. Data acquisition with a short echo time of 8 mus starts following a time delay of inversion time (TI1) for the inverted water magnetization to reach a null point and a time delay of TI2 for the inverted fat magnetization to reach a null point. The suppression of long-T(2) species depends on proper combination of TI1, TI2, and pulse repetition time. It is insensitive to radiofrequency inhomogeneities because of the adiabatic inversion pulses. The feasibility of this dual inversion recovery ultrashort echo time technique was demonstrated on phantoms, cadaveric specimens, and healthy volunteers, using a clinical 3-T scanner. High image contrast was achieved for the deep radial and calcified layers of articular cartilage, cortical bone, and the Achilles tendon.

Entities:  

Mesh:

Year:  2010        PMID: 20099332      PMCID: PMC4682675          DOI: 10.1002/mrm.22257

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

Review 1.  Magnetic resonance: an introduction to ultrashort TE (UTE) imaging.

Authors:  Matthew D Robson; Peter D Gatehouse; Mark Bydder; Graeme M Bydder
Journal:  J Comput Assist Tomogr       Date:  2003 Nov-Dec       Impact factor: 1.826

2.  Musculoskeletal MRI at 3.0 T: relaxation times and image contrast.

Authors:  Garry E Gold; Eric Han; Jeff Stainsby; Graham Wright; Jean Brittain; Christopher Beaulieu
Journal:  AJR Am J Roentgenol       Date:  2004-08       Impact factor: 3.959

3.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

4.  Designing long-T2 suppression pulses for ultrashort echo time imaging.

Authors:  Peder E Z Larson; Paul T Gurney; Krishna Nayak; Garry E Gold; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

5.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

6.  Ultrashort TE spectroscopic imaging (UTESI): application to the imaging of short T2 relaxation tissues in the musculoskeletal system.

Authors:  Jiang Du; Atsushi M Takahashi; Christine B Chung
Journal:  J Magn Reson Imaging       Date:  2009-02       Impact factor: 4.813

7.  Slice-selective tunable-flip adiabatic low peak-power excitation pulse.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

8.  Design of practical T2-selective RF excitation (TELEX) pulses.

Authors:  M S Sussman; J M Pauly; G A Wright
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

9.  Water- and fat-suppressed proton projection MRI (WASPI) of rat femur bone.

Authors:  Yaotang Wu; Guangping Dai; Jerome L Ackerman; Mirko I Hrovat; Melvin J Glimcher; Brian D Snyder; Ara Nazarian; David A Chesler
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

10.  In vivo MRI of submillisecond T(2) species with two-dimensional and three-dimensional radial sequences and applications to the measurement of cortical bone water.

Authors:  Aranee Techawiboonwong; Hee Kwon Song; Felix W Wehrli
Journal:  NMR Biomed       Date:  2008-01       Impact factor: 4.044

View more
  39 in total

1.  Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI.

Authors:  Cheng Li; Jeremy F Magland; Hamidreza Saligheh Rad; Hee Kwon Song; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

2.  UTE MRI of the Osteochondral Junction.

Authors:  Won C Bae; Reni Biswas; Karen Chen; Eric Y Chang; Christine B Chung
Journal:  Curr Radiol Rep       Date:  2014-02-01

Review 3.  Magnetic Resonance Imaging of Hard Tissues and Hard Tissue Engineered Bio-substitutes.

Authors:  Simone Mastrogiacomo; Weiqiang Dou; John A Jansen; X Frank Walboomers
Journal:  Mol Imaging Biol       Date:  2019-12       Impact factor: 3.488

Review 4.  Quantitative magnetic resonance imaging of the lumbar intervertebral discs.

Authors:  Dosik Hwang; Sewon Kim; Nirusha A Abeydeera; Sheronda Statum; Koichi Masuda; Christine B Chung; Palanan Siriwanarangsun; Won C Bae
Journal:  Quant Imaging Med Surg       Date:  2016-12

Review 5.  Ultrashort time to echo magnetic resonance techniques for the musculoskeletal system.

Authors:  Palanan Siriwanarangsun; Sheronda Statum; Reni Biswas; Won C Bae; Christine B Chung
Journal:  Quant Imaging Med Surg       Date:  2016-12

6.  Fat suppression for ultrashort echo time imaging using a single-point Dixon method.

Authors:  Hyungseok Jang; Michael Carl; Yajun Ma; Saeed Jerban; Tan Guo; Wei Zhao; Eric Y Chang; Jiang Du
Journal:  NMR Biomed       Date:  2019-02-15       Impact factor: 4.044

Review 7.  Quantitative MRI of articular cartilage and its clinical applications.

Authors:  Xiaojuan Li; Sharmila Majumdar
Journal:  J Magn Reson Imaging       Date:  2013-10-02       Impact factor: 4.813

8.  UTE bi-component analysis of T2* relaxation in articular cartilage.

Authors:  H Shao; E Y Chang; C Pauli; S Zanganeh; W Bae; C B Chung; G Tang; J Du
Journal:  Osteoarthritis Cartilage       Date:  2015-09-14       Impact factor: 6.576

9.  Ultrashort echo time (UTE) imaging of receptor targeted magnetic iron oxide nanoparticles in mouse tumor models.

Authors:  Liya Wang; Xiaodong Zhong; Weiping Qian; Jing Huang; Zehong Cao; Qiqi Yu; Malgorzata Lipowska; Run Lin; Andrew Wang; Lily Yang; Hui Mao
Journal:  J Magn Reson Imaging       Date:  2014-11       Impact factor: 4.813

10.  Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CT (μCT) evaluation of the temporomandibular joint (TMJ) condylar morphology.

Authors:  Daniel Geiger; Won C Bae; Sheronda Statum; Jiang Du; Christine B Chung
Journal:  Skeletal Radiol       Date:  2013-10-04       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.