Literature DB >> 22161636

Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI.

Cheng Li1, Jeremy F Magland, Hamidreza Saligheh Rad, Hee Kwon Song, Felix W Wehrli.   

Abstract

Ultrashort echo time (UTE) imaging with soft-tissue suppression reveals short-T(2) components (typically hundreds of microseconds to milliseconds) ordinarily not captured or obscured by long-T(2) tissue signals on the order of tens of milliseconds or longer. Therefore, the technique enables visualization and quantification of short-T(2) proton signals such as those in highly collagenated connective tissues. This work compares the performance of the three most commonly used long-T(2) suppression UTE sequences, i.e., echo subtraction (dual-echo UTE), saturation via dual-band saturation pulses (dual-band UTE), and inversion by adiabatic inversion pulses (IR-UTE) at 3 T, via Bloch simulations and experimentally in vivo in the lower extremities of test subjects. For unbiased performance comparison, the acquisition parameters are optimized individually for each sequence to maximize short-T(2) signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between short- and long-T(2) components. Results show excellent short-T(2) contrast which is achieved with these optimized sequences. A combination of dual-band UTE with dual-echo UTE provides good short-T(2) SNR and CNR with less sensitivity to B(1) homogeneity. IR-UTE has the lowest short-T(2) SNR efficiency but provides highly uniform short-T(2) contrast and is well suited for imaging short-T(2) species with relatively short T(1) such as bone water.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22161636      PMCID: PMC3516295          DOI: 10.1002/mrm.23267

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI.

Authors:  Hamidreza Saligheh Rad; Shing Chun Benny Lam; Jeremy F Magland; Henry Ong; Cheng Li; Hee Kwon Song; James Love; Felix W Wehrli
Journal:  NMR Biomed       Date:  2011-01-28       Impact factor: 4.044

Review 2.  Magnetic resonance: an introduction to ultrashort TE (UTE) imaging.

Authors:  Matthew D Robson; Peter D Gatehouse; Mark Bydder; Graeme M Bydder
Journal:  J Comput Assist Tomogr       Date:  2003 Nov-Dec       Impact factor: 1.826

3.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

4.  Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone.

Authors:  Jiang Du; Michael Carl; Mark Bydder; Atsushi Takahashi; Christine B Chung; Graeme M Bydder
Journal:  J Magn Reson       Date:  2010-09-25       Impact factor: 2.229

5.  Designing long-T2 suppression pulses for ultrashort echo time imaging.

Authors:  Peder E Z Larson; Paul T Gurney; Krishna Nayak; Garry E Gold; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

6.  Ultra-short echo time cardiovascular magnetic resonance of atherosclerotic carotid plaque.

Authors:  Cheuk F Chan; Niall G Keenan; Sonia Nielles-Vallespin; Peter Gatehouse; Mary N Sheppard; Joseph J Boyle; Dudley J Pennell; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2010-03-26       Impact factor: 5.364

7.  Measurement of phosphorus content in normal and osteomalacic rabbit bone by solid-state 3D radial imaging.

Authors:  S Anumula; J Magland; S L Wehrli; H Zhang; H Ong; H K Song; F W Wehrli
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

8.  Water- and fat-suppressed proton projection MRI (WASPI) of rat femur bone.

Authors:  Yaotang Wu; Guangping Dai; Jerome L Ackerman; Mirko I Hrovat; Melvin J Glimcher; Brian D Snyder; Ara Nazarian; David A Chesler
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

9.  Dual inversion recovery, ultrashort echo time (DIR UTE) imaging: creating high contrast for short-T(2) species.

Authors:  Jiang Du; Atsushi M Takahashi; Won C Bae; Christine B Chung; Graeme M Bydder
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

10.  In vivo MRI of submillisecond T(2) species with two-dimensional and three-dimensional radial sequences and applications to the measurement of cortical bone water.

Authors:  Aranee Techawiboonwong; Hee Kwon Song; Felix W Wehrli
Journal:  NMR Biomed       Date:  2008-01       Impact factor: 4.044

View more
  21 in total

1.  UTE MRI of the Osteochondral Junction.

Authors:  Won C Bae; Reni Biswas; Karen Chen; Eric Y Chang; Christine B Chung
Journal:  Curr Radiol Rep       Date:  2014-02-01

2.  Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study.

Authors:  Hyunyeol Lee; Xia Zhao; Hee Kwon Song; Rosaline Zhang; Scott P Bartlett; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2018-12-18       Impact factor: 4.668

3.  Bone mineral (31)P and matrix-bound water densities measured by solid-state (31)P and (1)H MRI.

Authors:  Alan C Seifert; Cheng Li; Chamith S Rajapakse; Mahdieh Bashoor-Zadeh; Yusuf A Bhagat; Alexander C Wright; Babette S Zemel; Antonios Zavaliangos; Felix W Wehrli
Journal:  NMR Biomed       Date:  2014-05-21       Impact factor: 4.044

4.  Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI.

Authors:  Neville D Gai; Ashkan A Malayeri; David A Bluemke
Journal:  MAGMA       Date:  2017-03-10       Impact factor: 2.310

Review 5.  Skeletal Muscle Quantitative Nuclear Magnetic Resonance Imaging and Spectroscopy as an Outcome Measure for Clinical Trials.

Authors:  Pierre G Carlier; Benjamin Marty; Olivier Scheidegger; Paulo Loureiro de Sousa; Pierre-Yves Baudin; Eduard Snezhko; Dmitry Vlodavets
Journal:  J Neuromuscul Dis       Date:  2016-03-03

6.  Theoretical analysis and optimization of ultrashort echo time (UTE) imaging contrast with off-resonance saturation.

Authors:  Michael Carl; Yajun Ma; Jiang Du
Journal:  Magn Reson Imaging       Date:  2018-03-08       Impact factor: 2.546

Review 7.  Magnetic resonance of calcified tissues.

Authors:  Felix W Wehrli
Journal:  J Magn Reson       Date:  2013-01-10       Impact factor: 2.229

Review 8.  Advances in imaging approaches to fracture risk evaluation.

Authors:  Mary Kate Manhard; Jeffry S Nyman; Mark D Does
Journal:  Transl Res       Date:  2016-10-17       Impact factor: 7.012

9.  Cortical bone water concentration: dependence of MR imaging measures on age and pore volume fraction.

Authors:  Cheng Li; Alan C Seifert; Hamidreza Saligheh Rad; Yusuf A Bhagat; Chamith S Rajapakse; Wenli Sun; Shing Chun Benny Lam; Felix W Wehrli
Journal:  Radiology       Date:  2014-05-02       Impact factor: 11.105

Review 10.  Qualitative and quantitative ultrashort-TE MRI of cortical bone.

Authors:  Jiang Du; Graeme M Bydder
Journal:  NMR Biomed       Date:  2012-12-28       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.