Literature DB >> 18222850

Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

J I Jackson1, C H Meyer, D G Nishimura, A Macovski.   

Abstract

In the technique known as gridding, the data samples are weighted for sampling density and convolved with a finite kernel, then resampled on a grid preparatory to a fast Fourier transform. The authors compare the artifact introduced into the image for various convolving functions of different sizes, including the Kaiser-Bessel window and the zero-order prolate spheroidal wave function (PSWF). They also show a convolving function that improves upon the PSWF in some circumstances.

Year:  1991        PMID: 18222850     DOI: 10.1109/42.97598

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  195 in total

1.  Myocardial wall tagging with undersampled projection reconstruction.

Authors:  D C Peters; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

Authors:  Mei-Lan Chu; Hing-Chiu Chang; Hsiao-Wen Chung; Trong-Kha Truong; Mustafa R Bashir; Nan-kuei Chen
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

3.  High-resolution sodium imaging of human brain at 7 T.

Authors:  Yongxian Qian; Tiejun Zhao; Hai Zheng; Jonathan Weimer; Fernando E Boada
Journal:  Magn Reson Med       Date:  2011-12-05       Impact factor: 4.668

4.  High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession.

Authors:  Dana C Peters; Daniel B Ennis; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

5.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

6.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

7.  Centering the projection reconstruction trajectory: reducing gradient delay errors.

Authors:  Dana C Peters; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

8.  Dynamic magnetic resonance imaging paragraph sign with radial scanning: a post-acquisition paragraph sign keyhole approach.

Authors:  R Lethmate; H Ratiney; F T A W Wajer; Y Crémillieux; D van Ormondt; D Graveron-Demilly
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

9.  Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction.

Authors:  Jiayu Song; Yanhui Liu; Sally L Gewalt; Gary Cofer; G Allan Johnson; Qing Huo Liu
Journal:  IEEE Trans Biomed Eng       Date:  2009-01-23       Impact factor: 4.538

10.  Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Authors:  Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.