Literature DB >> 16724304

Designing long-T2 suppression pulses for ultrashort echo time imaging.

Peder E Z Larson1, Paul T Gurney, Krishna Nayak, Garry E Gold, John M Pauly, Dwight G Nishimura.   

Abstract

Ultrashort echo time (UTE) imaging has shown promise as a technique for imaging tissues with T2 values of a few milliseconds or less. These tissues, such as tendons, menisci, and cortical bone, are normally invisible in conventional magnetic resonance imaging techniques but have signal in UTE imaging. They are difficult to visualize because they are often obscured by tissues with longer T2 values. In this article, new long-T2 suppression RF pulses that improve the contrast of short-T2 species are introduced. These pulses are improvements over previous long-T2 suppression pulses that suffered from poor off-resonance characteristics or T1 sensitivity. Short-T2 tissue contrast can also be improved by suppressing fat in some applications. Dual-band long-T2 suppression pulses that additionally suppress fat are also introduced. Simulations, along with phantom and in vivo experiments using 2D and 3D UTE imaging, demonstrate the feasibility, improved contrast, and improved sensitivity of these new long-T2 suppression pulses. The resulting images show predominantly short-T2 species, while most long-T2 species are suppressed. Copyright (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16724304      PMCID: PMC2942755          DOI: 10.1002/mrm.20926

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses.

Authors:  J P Wansapura; B L Daniel; J Pauly; K Butts
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

Review 2.  Magnetic resonance: an introduction to ultrashort TE (UTE) imaging.

Authors:  Matthew D Robson; Peter D Gatehouse; Mark Bydder; Graeme M Bydder
Journal:  J Comput Assist Tomogr       Date:  2003 Nov-Dec       Impact factor: 1.826

3.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

4.  Echo time optimization for linear combination myelin imaging.

Authors:  Logi Vidarsson; Steven M Conolly; Kelvin O Lim; Garry E Gold; John M Pauly
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

5.  Design of practical T2-selective RF excitation (TELEX) pulses.

Authors:  M S Sussman; J M Pauly; G A Wright
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

6.  MR imaging of articular cartilage of the knee: new methods using ultrashort TEs.

Authors:  G E Gold; D R Thedens; J M Pauly; K P Fechner; G Bergman; C F Beaulieu; A Macovski
Journal:  AJR Am J Roentgenol       Date:  1998-05       Impact factor: 3.959

7.  Fast three dimensional sodium imaging.

Authors:  F E Boada; J S Gillen; G X Shen; S Y Chang; K R Thulborn
Journal:  Magn Reson Med       Date:  1997-05       Impact factor: 4.668

8.  Magnetic resonance imaging of the liver with ultrashort TE (UTE) pulse sequences.

Authors:  Karyn E Chappell; Nayna Patel; Peter D Gatehouse; Janice Main; Basant K Puri; Simon D Taylor-Robinson; Graeme M Bydder
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

9.  Human imaging of phosphorus in cortical and trabecular bone in vivo.

Authors:  Matthew D Robson; Peter D Gatehouse; Graeme M Bydder; Stefan Neubauer
Journal:  Magn Reson Med       Date:  2004-05       Impact factor: 4.668

10.  Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (microMRI) study.

Authors:  Yang Xia; Jonathan B Moody; Hisham Alhadlaq
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

View more
  32 in total

1.  Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI.

Authors:  Cheng Li; Jeremy F Magland; Hamidreza Saligheh Rad; Hee Kwon Song; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

2.  Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI.

Authors:  Hamidreza Saligheh Rad; Shing Chun Benny Lam; Jeremy F Magland; Henry Ong; Cheng Li; Hee Kwon Song; James Love; Felix W Wehrli
Journal:  NMR Biomed       Date:  2011-01-28       Impact factor: 4.044

3.  UTE T2∗ mapping detects sub-clinical meniscus degeneration.

Authors:  E J McWalter; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2012-03-08       Impact factor: 6.576

4.  Selective 3D ultrashort TE imaging: comparison of "dual-echo" acquisition and magnetization preparation for improving short-T 2 contrast.

Authors:  Jürgen Rahmer; Ulrike Blume; Peter Börnert
Journal:  MAGMA       Date:  2007-03-13       Impact factor: 2.310

5.  Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.

Authors:  Peder E Z Larson; Steven M Conolly; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

6.  Bone mineral (31)P and matrix-bound water densities measured by solid-state (31)P and (1)H MRI.

Authors:  Alan C Seifert; Cheng Li; Chamith S Rajapakse; Mahdieh Bashoor-Zadeh; Yusuf A Bhagat; Alexander C Wright; Babette S Zemel; Antonios Zavaliangos; Felix W Wehrli
Journal:  NMR Biomed       Date:  2014-05-21       Impact factor: 4.044

7.  The effect of excitation and preparation pulses on nonslice selective 2D UTE bicomponent analysis of bound and free water in cortical bone at 3T.

Authors:  Shihong Li; Eric Y Chang; Won C Bae; Christine B Chung; Yanqing Hua; Yi Zhou; Jiang Du
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

8.  Yet more evidence that myelin protons can be directly imaged with UTE sequences on a clinical 3T scanner: Bicomponent T2* analysis of native and deuterated ovine brain specimens.

Authors:  Shu-Juan Fan; Yajun Ma; Yanchun Zhu; Adam Searleman; Nikolaus M Szeverenyi; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Med       Date:  2017-12-21       Impact factor: 4.668

9.  Short T2 imaging using a 3D double adiabatic inversion recovery prepared ultrashort echo time cones (3D DIR-UTE-Cones) sequence.

Authors:  Ya-Jun Ma; Yanchun Zhu; Xing Lu; Michael Carl; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

10.  Improved cortical bone specificity in UTE MR Imaging.

Authors:  Ethan M Johnson; Urvi Vyas; Pejman Ghanouni; Kim Butts Pauly; John M Pauly
Journal:  Magn Reson Med       Date:  2016-03-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.