Literature DB >> 19809857

Do tantalum and titanium cups show similar results in revision hip arthroplasty?

S Mehdi Jafari1, Benjamin Bender, Catelyn Coyle, Javad Parvizi, Peter F Sharkey, William J Hozack.   

Abstract

UNLABELLED: Porous surfaces are intended to enhance osteointegration of cementless implants. Tantalum has been introduced in an effort to enhance osseointegration potential of uncemented components. We therefore compared the clinical outcome of acetabular components with two different porous surfaces. We retrospectively reviewed 283 patients (295 hips) who underwent cementless revision hip arthroplasty with either an HA-coated titanium cup (207 patients, 214 hips) or porous tantalum cup (79 patients, 81 hips). The minimum followup was 24 months in both groups (titanium: average 51.8 months, range, 24-98 months; tantalum: average, 35.4 months, range, 24-63 months). The titanium and tantalum groups had a mechanical failure rate (clinical plus radiographic) of 8% and 6%, respectively. In hips with minor bone deficiency (type 1, 2A, 2B using the classification of Paprosky et al.), 6% of titanium cups and 4% of tantalum cups failed. In hips with major bone deficiency (type 2C, 3), 24% of titanium cups and 12% of tantalum cups developed failure. In the major bone deficiency group, the tantalum cups had fewer numbers of lucent zones around the cup. Eighty-two percent of titanium cups that failed did so at 6 months postoperatively or later, whereas 80% of tantalum cups that failed did so in less than 6 months. Radiographically in the major group, tantalum cups yielded better fixation. LEVEL OF EVIDENCE: Level III, retrospective comparative study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19809857      PMCID: PMC2807006          DOI: 10.1007/s11999-009-1090-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  27 in total

1.  Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium.

Authors:  H Matsuno; A Yokoyama; F Watari; M Uo; T Kawasaki
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

Review 2.  A porous tantalum trabecular metal: basic science.

Authors:  Robert Cohen
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2002-04

3.  Tissue response to porous tantalum acetabular cups: a canine model.

Authors:  J D Bobyn; K K Toh; S A Hacking; M Tanzer; J J Krygier
Journal:  J Arthroplasty       Date:  1999-04       Impact factor: 4.757

4.  Acetabular revision without cement.

Authors:  Tze-Pui Ng; Kwong-Yuen Chiu
Journal:  J Arthroplasty       Date:  2003-06       Impact factor: 4.757

5.  Acetabular component revision using a porous tantalum biomaterial: a case series.

Authors:  Arthur L Malkani; Matthew R Price; Charles H Crawford; Dale L Baker
Journal:  J Arthroplasty       Date:  2008-09-26       Impact factor: 4.757

6.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

7.  Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation.

Authors:  W G Paprosky; P G Perona; J M Lawrence
Journal:  J Arthroplasty       Date:  1994-02       Impact factor: 4.757

8.  Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years.

Authors:  Olav Reikerås; Ragnhild B Gunderson
Journal:  Acta Orthop Scand       Date:  2002-01

9.  Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid.

Authors:  Toshiki Miyaza; Hyun-Min Kim; Tadashi Kokubo; Chikara Ohtsuki; Hirofumi Kato; Takashi Nakamura
Journal:  Biomaterials       Date:  2002-02       Impact factor: 12.479

Review 10.  Novel bioactive materials with different mechanical properties.

Authors:  Tadashi Kokubo; Hyun-Min Kim; Masakazu Kawashita
Journal:  Biomaterials       Date:  2003-06       Impact factor: 12.479

View more
  26 in total

1.  [Mega cups and partial pelvic replacement].

Authors:  R von Eisenhart-Rothe; H Gollwitzer; A Toepfer; H Pilge; B M Holzapfel; H Rechl; R Gradinger
Journal:  Orthopade       Date:  2010-10       Impact factor: 1.087

2.  Uncemented Porous Tantalum Acetabular Components: Early Follow-Up and Failures in 599 Revision Total Hip Arthroplasties.

Authors:  William J Long; Nicolas O Noiseux; Tad M Mabry; Arlen D Hanssen; David G Lewallen
Journal:  Iowa Orthop J       Date:  2015

3.  [Treatment of acetabular defects with the trabecular metal revision system].

Authors:  G I Wassilew; V Janz; C Perka; M Müller
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 4.  Properties of open-cell porous metals and alloys for orthopaedic applications.

Authors:  Gladius Lewis
Journal:  J Mater Sci Mater Med       Date:  2013-07-13       Impact factor: 3.896

Review 5.  Systematic review on outcomes of acetabular revisions with highly-porous metals.

Authors:  Samik Banerjee; Kimona Issa; Bhaveen H Kapadia; Robert Pivec; Harpal S Khanuja; Michael A Mont
Journal:  Int Orthop       Date:  2013-11-01       Impact factor: 3.075

6.  The Otto Aufranc Award: Demineralized bone matrix around porous implants promotes rapid gap healing and bone ingrowth.

Authors:  Letitia Lim; J Dennis Bobyn; Kristian M Bobyn; Louis-Philippe Lefebvre; Michael Tanzer
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 7.  Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants.

Authors:  Eric Alexander Lewallen; Scott M Riester; Carolina A Bonin; Hilal Maradit Kremers; Amel Dudakovic; Sanjeev Kakar; Robert C Cohen; Jennifer J Westendorf; David G Lewallen; Andre J van Wijnen
Journal:  Tissue Eng Part B Rev       Date:  2014-12-18       Impact factor: 6.389

8.  Do Trabecular Metal Acetabular Components Reduce the Risk of Rerevision After Revision THA Performed for Periprosthetic Joint Infection? A Study Using the NJR Data Set.

Authors:  Gulraj S Matharu; Andrew Judge; David W Murray; Hemant G Pandit
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

9.  Reconstruction options for acetabular revision.

Authors:  Erica D Taylor; James A Browne
Journal:  World J Orthop       Date:  2012-07-18

10.  Tantalum coating on TiO2 nanotubes induces superior rate of matrix mineralization and osteofunctionality in human osteoblasts.

Authors:  Christine J Frandsen; Karla S Brammer; Kunbae Noh; Gary Johnston; Sungho Jin
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2014-01-14       Impact factor: 7.328

View more