Literature DB >> 11928902

Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years.

Olav Reikerås1, Ragnhild B Gunderson.   

Abstract

We report the outcome of 191 acetabular gritblasted titanium cups with a hemispherical design for press-fit insertion and coated with hydroxyapatite. The prosthesis was made of gritblasted titanium entirely coated with hydroxyapatite. 155 patients aged 15-78 years were operated on during the years 1991-1993 and followed for 7-10 years. During this period, 39 cups were revised because of mechanical loosening, a further 9 had radiolucent lines and 2 focal osteolysis. None of these 11 patients had clinical symptoms. Failure was associated with age, wear and radiolucency/osteolysis. At revision, we found that the soft tissues were discolored, and that most of the coating had disappeared. This design of hydroxyapatite-coated cups has a high rate of debonding and failure.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11928902     DOI: 10.1080/000164702317281503

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  12 in total

1.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

2.  Do tantalum and titanium cups show similar results in revision hip arthroplasty?

Authors:  S Mehdi Jafari; Benjamin Bender; Catelyn Coyle; Javad Parvizi; Peter F Sharkey; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

3.  Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature

Authors:  Xin Yu Mei; Ying Jia Gong; Oleg Safir; Allan Gross; Paul Kuzyk
Journal:  Can J Surg       Date:  2019-08-01       Impact factor: 2.089

4.  Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem.

Authors:  H Wangen; P Lereim; I Holm; R Gunderson; O Reikerås
Journal:  Int Orthop       Date:  2007-02-15       Impact factor: 3.075

5.  Effects of hydroxyapatite coating of cups used in hip revision arthroplasty.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2012-09-03       Impact factor: 3.717

6.  Effects of hydroxyapatite coating on survival of an uncemented femoral stem. A Swedish Hip Arthroplasty Register study on 4,772 hips.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2011-07-13       Impact factor: 3.717

7.  The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem.

Authors:  Young-Yool Chung; Chae-Hyun Im; Dae-Hee Kim; Ju-Yeong Heo; Young-Jae Jang
Journal:  Hip Pelvis       Date:  2014-09-29

8.  Results of a hydroxyapatite-coated femoral stem (Corail) in Chinese: a minimum 10-year follow-up.

Authors:  Jianda Xu; Zikang Xie; Jianning Zhao; Yi Gao; Hong Zhao; Libo Peng; Yuxing Qu
Journal:  Springerplus       Date:  2016-11-15

9.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

Review 10.  Bioactive coatings for orthopaedic implants-recent trends in development of implant coatings.

Authors:  Bill G X Zhang; Damian E Myers; Gordon G Wallace; Milan Brandt; Peter F M Choong
Journal:  Int J Mol Sci       Date:  2014-07-04       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.