Literature DB >> 19763252

Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

Ciprian N Ionita1, Andreea Dohatcu, Andrey Sinelnikov, Jason Sherman, Christos Keleshis, Ann M Paciorek, K R Hoffmann, D R Bednarek, S Rudin.   

Abstract

Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

Entities:  

Year:  2009        PMID: 19763252      PMCID: PMC2745172          DOI: 10.1117/12.812628

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  21 in total

1.  Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).

Authors:  C N Ionita; C Keleshis; V Patel; G Yadava; K R Hoffmann; D R Bednarek; A Jain; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

2.  Angiographic analysis of blood flow modification in cerebral aneurysm models with a new asymmetric stent.

Authors:  Zhou Wang; Ciprian Ionita; Stephen Rudin; Kenneth R Hoffmann; Adam B Paxton; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004-04

3.  Stents for intracranial aneurysms: the beginning of a new endovascular era?

Authors:  A K Wakhloo; G Lanzino; B B Lieber; L N Hopkins
Journal:  Neurosurgery       Date:  1998-08       Impact factor: 4.654

4.  Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents.

Authors:  Ciprian N Ionita; Y Hoi; H Meng; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004

5.  Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using Computational Fluid Dynamic (CFD) calculations in the Computed Tomography (CT) derived lumen.

Authors:  Minsuok Kim; Ciprian Ionita; Rekha Tranquebar; Kenneth R Hoffmann; Dale B Taulbee; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006

6.  Treatment of experimentally induced aneurysms with stents.

Authors:  Timo Krings; Franz J Hans; Walter Möller-Hartmann; Anna Brunn; Ruth Thiex; Thomas Schmitz-Rode; Peter Verken; Kira Scherer; Heiko Dreeskamp; Klaus P Stein; Joachim Gilsbach; Armin Thron
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

Review 7.  The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms.

Authors:  Baruch B Lieber; Matthew J Gounis
Journal:  Neurol Res       Date:  2002       Impact factor: 2.448

8.  Measurement of flow modification in phantom aneurysm model: comparison of coils and a longitudinally and axially asymmetric stent--initial findings.

Authors:  Stephen Rudin; Zhou Wang; Iacovos Kyprianou; Kenneth R Hoffmann; Ye Wu; Hui Meng; Lee R Guterman; Balazs Nemes; Daniel R Bednarek; Jacek Dmochowski; L Nelson Hopkins
Journal:  Radiology       Date:  2004-04       Impact factor: 11.105

9.  Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils.

Authors:  Ronald P Benitez; Marco T Silva; Jack Klem; Erol Veznedaroglu; Robert H Rosenwasser
Journal:  Neurosurgery       Date:  2004-06       Impact factor: 4.654

10.  Partially polyurethane-covered stent for cerebral aneurysm treatment.

Authors:  Hussain S Rangwala; Ciprian N Ionita; Stephen Rudin; Robert E Baier
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-05       Impact factor: 3.405

View more
  7 in total

1.  Investigation of metrics to assess vascular flow modifications for diverter device designs using hydrodynamics and angiographic studies.

Authors:  Ciprian N Ionita; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-23

2.  Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study.

Authors:  Ciprian N Ionita; Himanshu Suri; Sabareesh Nataranjian; Adnan Siddiqui; Elad Levy; Nelson L Hopkins; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

3.  Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector.

Authors:  Weiyuan Wang; Ciprian N Ionita; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-03-01

4.  Effects of metal coverage rate of flow diversion device on neointimal growth at side branch ostium and stented artery: an animal experiment in rabbit abdominal aorta.

Authors:  Bo Hong; Kuizhong Wang; Qinghai Huang; Yi Xu; Xinggen Fang; Zhen Li; Jianmin Liu
Journal:  Neuroradiology       Date:  2011-12-15       Impact factor: 2.804

5.  Assessment of contrast flow modification in aneurysms treated with closed-cell self-deploying asymmetric vascular stents (SAVS).

Authors:  Ciprian N Ionita; Weiyuan Wang; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010

6.  Real-time implementation of distortion corrections for a tiled EMCCD-based Solid State X-ray Image Intensifier (SSXII).

Authors:  C Keleshis; Kr Hoffmann; J Lee; H Hamwi; W Wang; Cn Ionita; Dr Bednarek; A Verevkin; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

7.  Effect of injection technique on temporal parametric imaging derived from digital subtraction angiography in patient specific phantoms.

Authors:  Ciprian N Ionita; Victor L Garcia; Daniel R Bednarek; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.