Assessment of contrast flow modification in aneurysms treated with closed-cell self-deploying asymmetric vascular stents (SAVS).

Ciprian N Ionita1, Weiyuan Wang, Daniel R Bednarek, Stephen Rudin.   

Abstract

The Asymmetric Vascular Stent (AVS) for intracranial aneurysm (IA) treatment is an experimental device, specially designed for intra-aneurysmal blood flow diversion and thrombosis promotion. The stent has a low-porous patch to cover only the aneurysm neck while the rest of the stent is very porous to avoid blockage of adjacent branches. The latest AVS design is similar to state-of-art, closed-cell, self-expanding, neurovascular stent. The stents were used to treat sixteen rabbit-elastase aneurysm models. The treatment effect was analyzed using normalized-time-density-curves (NTDC) measured by pixel-value integration over a region-of-interest containing the aneurysm. Normalization constant was the total bolus injection determined angiographically. Based on NTDC measurement, five quantities were derived to describe the contrast flow. Two are related to the amount of contrast entering the aneurysm: NTDC peak and NTDC input slope. The other three are related to contrast presence in the aneurysmal dome: time-to-peak (TTP), wash-out-time (WOT) and mean-transit-time (MTT). Flow modification descriptions using the contrast related quantities were expressed as a pre-/post-stented NTDC parameter ratio, while the time related quantities were expressed as a post-/pre-stented ratio, so that ratios smaller than one indicate a desired effect. Thirteen aneurysms were treated successfully and achieved significant aneurysm occlusion. For these cases, the resulting average parameters were: peak-ratio=0.17±0.21; input-slope-ratio=0.19±0.24, TTP-ratio=0.17±0.21, WOT-ratio=0.58±0.73 and MTT-ratio=0.65±0.97). All the quantities revealed decreased aneurysmal flow due to blood flow diversion using the new self-expanding asymmetrical vascular stent (SAVS). Treatment outcome results and angiographic analysis indicate that the new self-deploying stent design has great potential for clinical implementation.

Entities:  

Year:  2010        PMID: 21243093      PMCID: PMC3021376          DOI: 10.1117/12.844327

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  13 in total

Review 1.  X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature.

Authors:  S D Shpilfoygel; R A Close; D J Valentino; G R Duckwiler
Journal:  Med Phys       Date:  2000-09       Impact factor: 4.071

2.  Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents.

Authors:  Ciprian N Ionita; Y Hoi; H Meng; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004

3.  Microangiographic Image Guided Localization of a New Asymmetric Stent for Treatment of Cerebral Aneurysms.

Authors:  Ciprian N Ionita; Stephen Rudin; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

4.  Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using Computational Fluid Dynamic (CFD) calculations in the Computed Tomography (CT) derived lumen.

Authors:  Minsuok Kim; Ciprian Ionita; Rekha Tranquebar; Kenneth R Hoffmann; Dale B Taulbee; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006

5.  Progress in the Development of a new Angiography Suite including the High Resolution Micro-Angiographic Fluoroscope (MAF), a Control, Acquisition, Processing, and Image Display System (CAPIDS), and a New Detector Changer Integrated into a Commercial C-Arm Angiography Unit to Enable Clinical Use.

Authors:  Weiyuan Wang; Ciprian N Ionita; Christos Keleshis; Andrew Kuhls-Gilcrist; Amit Jain; Daniel Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-23

6.  Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

Authors:  A Dohatcu; C N Ionita; A Paciorek; D R Bednarek; K R Hoffmann; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

7.  Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

Authors:  Ciprian N Ionita; Andreea Dohatcu; Andrey Sinelnikov; Jason Sherman; Christos Keleshis; Ann M Paciorek; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

8.  Evaluation of intra-aneurysmal blood flow by digital subtraction angiography: blood flow change after coil embolization.

Authors:  Fumio Asakura; Hiroshi Tenjin; Noriaki Sugawa; Satoshi Kimura; Fumiya Oki
Journal:  Surg Neurol       Date:  2003-04

9.  Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography.

Authors:  Chander Sadasivan; Liliana Cesar; Jaehoon Seong; Ajay K Wakhloo; Baruch B Lieber
Journal:  IEEE Trans Med Imaging       Date:  2009-01-19       Impact factor: 10.048

10.  Partially polyurethane-covered stent for cerebral aneurysm treatment.

Authors:  Hussain S Rangwala; Ciprian N Ionita; Stephen Rudin; Robert E Baier
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-05       Impact factor: 3.405

View more
  5 in total

1.  Investigation of metrics to assess vascular flow modifications for diverter device designs using hydrodynamics and angiographic studies.

Authors:  Ciprian N Ionita; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-23

2.  Evaluation of a second-generation self-expanding variable-porosity flow diverter in a rabbit elastase aneurysm model.

Authors:  C N Ionita; S K Natarajan; W Wang; L N Hopkins; E I Levy; A H Siddiqui; D R Bednarek; S Rudin
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

3.  Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study.

Authors:  Ciprian N Ionita; Himanshu Suri; Sabareesh Nataranjian; Adnan Siddiqui; Elad Levy; Nelson L Hopkins; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

4.  Effect of injection technique on temporal parametric imaging derived from digital subtraction angiography in patient specific phantoms.

Authors:  Ciprian N Ionita; Victor L Garcia; Daniel R Bednarek; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-13

5.  Analysis of intra-aneurysmal flow for cerebral aneurysms with cerebral angiography.

Authors:  L-D Jou; M E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.