Literature DB >> 25302010

Effect of injection technique on temporal parametric imaging derived from digital subtraction angiography in patient specific phantoms.

Ciprian N Ionita1, Victor L Garcia2, Daniel R Bednarek2, Kenneth V Snyder3, Adnan H Siddiqui3, Elad I Levy3, Stephen Rudin1.   

Abstract

Parametric imaging maps (PIM's) derived from digital subtraction angiography (DSA) for the cerebral arterial flow assessment in clinical settings have been proposed, but experiments have yet to determine the reliability of such studies. For this study, we have observed the effects of different injection techniques on PIM's. A flow circuit set to physiologic conditions was created using an internal carotid artery phantom. PIM's were derived for two catheter positions, two different contrast bolus injection volumes (5ml and 10 ml), and four injection rates (5, 10, 15 and 20 ml/s). Using a gamma variate fitting approach, we derived PIM's for mean-transit-time (MTT), time-to-peak (TTP) and bolus-arrivaltime (BAT). For the same injection rates, a larger bolus resulted in an increased MTT and TTP, while a faster injection rate resulted in a shorter MTT, TTP, and BAT. In addition, the position of the catheter tip within the vasculature directly affected the PIM. The experiment showed that the PIM is strongly correlated with the injection conditions, and, therefore, they have to be interpreted with caution. PIM images must be taken from the same patient to be able to be meaningfully compared. These comparisons can include pre- and post-treatment images taken immediately before and after an interventional procedure or simultaneous arterial flow comparisons through the left and right cerebral hemispheres. Due to the strong correlation between PIM and injection conditions, this study indicates that this assessment method should be used only to compare flow changes before and after treatment within the same patient using the same injection conditions.

Entities:  

Keywords:  DSA; MTT; Mean Transit Time; Parametric Imaging Maps; Time to Peak

Year:  2014        PMID: 25302010      PMCID: PMC4187403          DOI: 10.1117/12.2041347

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  18 in total

Review 1.  Perfusion CT: a worthwhile enhancement?

Authors:  K A Miles; M R Griffiths
Journal:  Br J Radiol       Date:  2003-04       Impact factor: 3.039

2.  Color-coded digital subtraction angiography: the end of a monochromatic era?

Authors:  G Benndorf
Journal:  AJNR Am J Neuroradiol       Date:  2010-04-15       Impact factor: 3.825

3.  Measurement of absolute flow rate in vessels using a stereoscopic DSA system.

Authors:  L E Fencil; K Doi; K G Chua; K R Hoffman
Journal:  Phys Med Biol       Date:  1989-06       Impact factor: 3.609

4.  Investigation of metrics to assess vascular flow modifications for diverter device designs using hydrodynamics and angiographic studies.

Authors:  Ciprian N Ionita; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-23

5.  Evaluation of a second-generation self-expanding variable-porosity flow diverter in a rabbit elastase aneurysm model.

Authors:  C N Ionita; S K Natarajan; W Wang; L N Hopkins; E I Levy; A H Siddiqui; D R Bednarek; S Rudin
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

6.  Digital subtraction angiography (DSA): a neurosurgical perspective.

Authors:  P Butler
Journal:  Br J Neurosurg       Date:  1987       Impact factor: 1.596

7.  Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study.

Authors:  Ciprian N Ionita; Himanshu Suri; Sabareesh Nataranjian; Adnan Siddiqui; Elad Levy; Nelson L Hopkins; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

8.  Digital angiography: a perspective.

Authors:  C A Mistretta; A B Crummy; C M Strother
Journal:  Radiology       Date:  1981-05       Impact factor: 11.105

9.  Assessment of contrast flow modification in aneurysms treated with closed-cell self-deploying asymmetric vascular stents (SAVS).

Authors:  Ciprian N Ionita; Weiyuan Wang; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010

10.  Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

Authors:  Ciprian N Ionita; Andreea Dohatcu; Andrey Sinelnikov; Jason Sherman; Christos Keleshis; Ann M Paciorek; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01
View more
  15 in total

1.  3D Printed Abdominal Aortic Aneurysm Phantom for Image Guided Surgical Planning with a Patient Specific Fenestrated Endovascular Graft System.

Authors:  Karen M Meess; Richard L Izzo; Maciej L Dryjski; Richard E Curl; Linda M Harris; Michael Springer; Adnan H Siddiqui; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

2.  3D Printed Cardiac Phantom for Procedural Planning of a Transcatheter Native Mitral Valve Replacement.

Authors:  Richard L Izzo; Ryan P O'Hara; Vijay Iyer; Rose Hansen; Karen M Meess; S V Setlur Nagesh; Stephen Rudin; Adnan H Siddiqui; Michael Springer; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-04-05

3.  Angiographic assessment of the efficacy of flow diverter treatment for cerebral aneurysms.

Authors:  Chander Sadasivan; Ronak Dholakia; Lissa Peeling; Philipp Gölitz; Arnd Doerfler; Baruch B Lieber; David J Fiorella; Henry H Woo
Journal:  Interv Neuroradiol       Date:  2019-07-11       Impact factor: 1.610

4.  Use of biplane quantitative angiographic imaging with ensemble neural networks to assess reperfusion status during mechanical thrombectomy.

Authors:  Mohammad Mahdi Shiraz Bhurwani; Kenneth V Snyder; Muhammad Waqas; Maxim Mokin; Ryan A Rava; Alexander R Podgorsak; Kelsey N Sommer; Jason M Davies; Elad I Levy; Adnan H Siddiqui; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

5.  Subsequent haemorrhage in children with untreated brain arteriovenous malformation: Higher risk with unbalanced inflow and outflow angioarchitecture.

Authors:  Li Ma; Xiao-Lin Chen; Yu Chen; Chun-Xue Wu; Jun Ma; Yuan-Li Zhao
Journal:  Eur Radiol       Date:  2016-11-29       Impact factor: 5.315

6.  A Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study.

Authors:  A Sonig; S V Setlur Nagesh; V S Fennell; S Gandhi; L Rangel-Castilla; C N Ionita; K V Snyder; L N Hopkins; D R Bednarek; S Rudin; A H Siddiqui; E I Levy
Journal:  AJNR Am J Neuroradiol       Date:  2018-02-15       Impact factor: 3.825

7.  Angiographic analysis for phantom simulations of endovascular aneurysm treatments with a new fully retrievable asymmetric flow diverter.

Authors:  Aradhana Yoganand; Rachel P Wood; Carlos Jimenez; Adnan Siddiqui; Kenneth Snyder; S V Setlur Nagesh; D R Bednarek; S Rudin; Robert Baier; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-17

8.  Sensitivity evaluation of DSA-based parametric imaging using Doppler ultrasound in neurovascular phantoms.

Authors:  A Balasubramoniam; D R Bednarek; S Rudin; C N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-29

9.  Performance of angiographic parametric imaging in locating infarct core in large vessel occlusion acute ischemic stroke patients.

Authors:  Ryan A Rava; Maxim Mokin; Kenneth V Snyder; Muhammad Waqas; Adnan H Siddiqui; Jason M Davies; Elad I Levy; Ciprian N Ionita
Journal:  J Med Imaging (Bellingham)       Date:  2020-02-11

10.  The Aneurysm Occlusion Assistant, an AI platform for real time surgical guidance of intracranial aneurysms.

Authors:  Kyle A Williams; Alexander R Podgorsak; Mohammad Mahdi Shiraz Bhurwani; Ryan A Rava; Kelsey N Sommer; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15
View more