Literature DB >> 18837459

Partially polyurethane-covered stent for cerebral aneurysm treatment.

Hussain S Rangwala1,2, Ciprian N Ionita1,3,4, Stephen Rudin1,3,4,2,5, Robert E Baier6,2.   

Abstract

Partially polyurethane-covered stent (PPCS) is proposed for the treatment of cerebral aneurysms. The PPCSs were observed to substantially modify the flow entering the aneurysm in a patient-specific aneurysm phantom (PSAP). These stents can act as flow modulators and the polyurethane (PU) membrane can provide a smooth scaffold for restoring the structural integrity of the diseased vessel. Partial coating of the stent aids in sealing only the entrance to the aneurysm while keeping the perforators around the aneurysm open and patent. Biocompatibility of the PU membrane was monitored using contact angle measurements to show that critical surface tension (CST) values remained in the thromboresistant range of 20-30 mN/m. Stent flexibility, stiffness, and pressure-diameter relationship showed no significant change after asymmetric PU film application. No delamination of the PU membrane from the stent was observed within the working strains of the stent. The flow modulating capability of the PPCS was monitored by intentionally orienting the stent to cover either the proximal or the distal regions along the neck of the PSAP. Time density curves (TDCs) compared the relative metrics of input rate, washout rate, residence time, and influx in the aneurysm before and after the stent placement. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18837459      PMCID: PMC2720836          DOI: 10.1002/jbm.b.31229

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.405


  21 in total

1.  Stent longitudinal flexibility: a comparison of 13 stent designs before and after balloon expansion.

Authors:  J A Ormiston; S R Dixon; M W Webster; P N Ruygrok; J T Stewart; I Minchington; T West
Journal:  Catheter Cardiovasc Interv       Date:  2000-05       Impact factor: 2.692

2.  Structural evaluation of radially expandable cardiovascular stents encased in a polyurethane film.

Authors:  Steve Trigwell; Samiran De; Rajesh Sharma; Malay K Mazumder; Jawahar L Mehta
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2006-02       Impact factor: 3.368

3.  Microangiographic Image Guided Localization of a New Asymmetric Stent for Treatment of Cerebral Aneurysms.

Authors:  Ciprian N Ionita; Stephen Rudin; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

4.  Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using Computational Fluid Dynamic (CFD) calculations in the Computed Tomography (CT) derived lumen.

Authors:  Minsuok Kim; Ciprian Ionita; Rekha Tranquebar; Kenneth R Hoffmann; Dale B Taulbee; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006

5.  Anatomically shaped internal carotid artery aneurysm in vitro model for flow analysis to evaluate stent effect.

Authors:  Krisztina Baráth; Francis Cassot; Daniel A Rüfenacht; Jean H D Fasel
Journal:  AJNR Am J Neuroradiol       Date:  2004 Nov-Dec       Impact factor: 3.825

6.  Treatment of experimentally induced aneurysms with stents.

Authors:  Timo Krings; Franz J Hans; Walter Möller-Hartmann; Anna Brunn; Ruth Thiex; Thomas Schmitz-Rode; Peter Verken; Kira Scherer; Heiko Dreeskamp; Klaus P Stein; Joachim Gilsbach; Armin Thron
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

7.  Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

Authors:  A Dohatcu; C N Ionita; A Paciorek; D R Bednarek; K R Hoffmann; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

8.  Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience.

Authors:  Isabel Wanke; Arnd Doerfler; Beate Schoch; Dietmar Stolke; Michael Forsting
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

9.  Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging.

Authors:  Jr Sherman; Hs Rangwala; Cn Ionita; Ac Dohatcu; Jw Lee; Dr Bednarek; Kr Hoffmann; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

10.  Double-stent method: therapeutic alternative for small wide-necked aneurysms. Technical note.

Authors:  Arnd Doerfler; Isabel Wanke; Thomas Egelhof; Dietmar Stolke; Michael Forsting
Journal:  J Neurosurg       Date:  2004-01       Impact factor: 5.115

View more
  8 in total

1.  Investigation of metrics to assess vascular flow modifications for diverter device designs using hydrodynamics and angiographic studies.

Authors:  Ciprian N Ionita; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-23

2.  3D Printed Abdominal Aortic Aneurysm Phantom for Image Guided Surgical Planning with a Patient Specific Fenestrated Endovascular Graft System.

Authors:  Karen M Meess; Richard L Izzo; Maciej L Dryjski; Richard E Curl; Linda M Harris; Michael Springer; Adnan H Siddiqui; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

3.  Design Optimization for Accurate Flow Simulations in 3D Printed Vascular Phantoms Derived from Computed Tomography Angiography.

Authors:  Kelsey Sommer; Richard L Izzo; Lauren Shepard; Alexander R Podgorsak; Stephen Rudin; Adnan H Siddiqui; Michael F Wilson; Erin Angel; Zaid Said; Michael Springer; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

4.  Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study.

Authors:  Ciprian N Ionita; Himanshu Suri; Sabareesh Nataranjian; Adnan Siddiqui; Elad Levy; Nelson L Hopkins; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

5.  Angiographic analysis for phantom simulations of endovascular aneurysm treatments with a new fully retrievable asymmetric flow diverter.

Authors:  Aradhana Yoganand; Rachel P Wood; Carlos Jimenez; Adnan Siddiqui; Kenneth Snyder; S V Setlur Nagesh; D R Bednarek; S Rudin; Robert Baier; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-17

6.  Assessment of contrast flow modification in aneurysms treated with closed-cell self-deploying asymmetric vascular stents (SAVS).

Authors:  Ciprian N Ionita; Weiyuan Wang; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010

7.  Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

Authors:  Ciprian N Ionita; Andreea Dohatcu; Andrey Sinelnikov; Jason Sherman; Christos Keleshis; Ann M Paciorek; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

8.  Synthesis and evaluation of poly(hexamethylene-urethane) and PEG-poly(hexamethylene-urethane) and their cholesteryl oleyl carbonate composites for human blood biocompatibility.

Authors:  Mei Fen Shih; Min Da Shau; Cheng Chih Hsieh; Jong Yuh Cherng
Journal:  Molecules       Date:  2011-09-28       Impact factor: 4.411

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.