Literature DB >> 19777121

Real-time implementation of distortion corrections for a tiled EMCCD-based Solid State X-ray Image Intensifier (SSXII).

C Keleshis1, Kr Hoffmann, J Lee, H Hamwi, W Wang, Cn Ionita, Dr Bednarek, A Verevkin, S Rudin.   

Abstract

The new Solid State X-ray Image Intensifier (SSXII) is being designed based on a modular imaging array of Electron Multiplying Charge Couple Devices (EMCCD). Each of the detector modules consists of a CsI(Tl) phosphor coupled to a fiber-optic plate, a fiber-optic taper (FOT), and an EMCCD sensor with its electronics. During the optical coupling and alignment of the modules into an array form, small orientation misalignments, such as rotation and translation of the EMCCD sensors, are expected. In addition, barrel distortion will result from the FOTs. Correction algorithms have been developed by our group for all the above artifacts. However, it is critical for the system's performance to correct these artifacts in real-time (30 fps). To achieve this, we will use two-dimensional Look-Up-Tables (LUT) (each for x and y coordinates), which map the corrected pixel locations to the acquired-image pixel locations. To evaluate the feasibility of this approach, this process is simulated making use of parallel coding techniques to allow real-time distortion corrections for up to sixteen modules when a standard quad processor is used. The results of this simulation confirm that tiled field-of-views (FOV) comparable with those of flat panel detectors can be generated in ~17 ms (>30 fps). The increased FOV enabled through correction of tiled images, combined with the EMCCD characteristics of low noise, negligible lag and high sensitivity, should make possible the practical use of the SSXII with substantial advantages over conventional clinical systems.

Entities:  

Year:  2009        PMID: 19777121      PMCID: PMC2748406          DOI: 10.1117/12.813603

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  12 in total

1.  Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).

Authors:  C N Ionita; C Keleshis; V Patel; G Yadava; K R Hoffmann; D R Bednarek; A Jain; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

2.  Distortion, Orientation, and Translation Corrections of Tiled EMCCD Detectors for the New Solid State X-ray Image Intensifier (SSXII).

Authors:  Hidab Hamwi; Joseph W Lee; Kenneth R Hoffmann; Stephen Rudin; Aleksandr Verevkin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

3.  The Solid-State X-Ray Image Intensifier (SSXII): An EMCCD-Based X-Ray Detector.

Authors:  Andrew Kuhls-Gilcrist; Girijesh Yadava; Vikas Patel; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

4.  New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy.

Authors:  Stephen Rudin; Andrew T Kuhls; Girijesh K Yadava; Gaurav C Josan; Ye Wu; Ravishankar N Chityala; Hussain S Rangwala; N Ciprian Ionita; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-12-02

5.  New microangiography system development providing improved small vessel imaging, increased contrast to noise ratios, and multi-view 3D reconstructions.

Authors:  Andrew T Kuhls; Vikas Patel; Ciprian Ionita; Peter B Noël; Alan M Walczak; Hussain S Rangwala; Kenneth R Hoffmann; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006

6.  Progress in electron-multiplying CCD (EMCCD) based, high-resolution, high-sensitivity x-ray detector for fluoroscopy and radiography.

Authors:  Andrew T Kuhls; Girijesh Yadava; Vikas Patel; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2007

7.  Microangiographic Image Guided Localization of a New Asymmetric Stent for Treatment of Cerebral Aneurysms.

Authors:  Ciprian N Ionita; Stephen Rudin; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

8.  Endovascular image-guided interventions (EIGIs).

Authors:  Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

9.  Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

Authors:  Ciprian N Ionita; Andreea Dohatcu; Andrey Sinelnikov; Jason Sherman; Christos Keleshis; Ann M Paciorek; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

10.  Generalized Objective Performance Assessment of a New High-Sensitivity Microangiographic Fluoroscopic (HSMAF) Imaging System.

Authors:  Girijesh K Yadava; Stephen Rudin; Andrew T Kuhls-Gilcrist; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008
View more
  1 in total

1.  Image acquisition, geometric correction and display of images from a 2×2 x-ray detector array based on Electron Multiplying Charge Coupled Device (EMCCD) technology.

Authors:  S N Swetadri Vasan; P Sharma; Ciprian N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin