Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).

C N Ionita1, C Keleshis, V Patel, G Yadava, K R Hoffmann, D R Bednarek, A Jain, S Rudin.   

Abstract

New advances in catheter technology and remote actuation for minimally invasive procedures are continuously increasing the demand for better x-ray imaging technology. The new x-ray high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) detector offers high resolution and real-time image-guided capabilities which are unique when compared with commercially available detectors. This detector consists of a 300 μm CsI input phosphor coupled to a dual stage GEN2 micro-channel plate light image intensifier (LII), followed by minifying fiber-optic taper coupled to a CCD chip. The HS-MAF detector image array is 1024×1024 pixels, with a 12 bit depth capable of imaging at 30 frames per second. The detector has a round field of view with 4 cm diameter and 35 microns pixels. The LII has a large variable gain which allows usage of the detector at very low exposures characteristic of fluoroscopic ranges while maintaining very good image quality. The custom acquisition program allows real-time image display and data storage. We designed a set of in-vivo experimental interventions in which placement of specially designed endovascular stents were evaluated with the new detector and with a standard x-ray image intensifier (XII). Capabilities such fluoroscopy, angiography and ROI-CT reconstruction using rotational angiography data were implemented and verified. The images obtained during interventions under radiographic control with the HS-MAF detector were superior to those with the XII. In general, the device feature markers, the device structures, and the vessel geometry were better identified with the new detector. High-resolution detectors such as HS-MAF can vastly improve the accuracy of localization and tracking of devices such stents or catheters.

Entities:  

Year:  2008        PMID: 18958294      PMCID: PMC2572822          DOI: 10.1117/12.770297

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  13 in total

1.  1999 ARRS Executive Council Award. Creation of saccular aneurysms in the rabbit: a model suitable for testing endovascular devices. American Roentgen Ray Society.

Authors:  T A Altes; H J Cloft; J G Short; A DeGast; H M Do; G A Helm; D F Kallmes
Journal:  AJR Am J Roentgenol       Date:  2000-02       Impact factor: 3.959

2.  Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

3.  New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy.

Authors:  Stephen Rudin; Andrew T Kuhls; Girijesh K Yadava; Gaurav C Josan; Ye Wu; Ravishankar N Chityala; Hussain S Rangwala; N Ciprian Ionita; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-12-02

Review 4.  Vascular and endovascular neurosurgery.

Authors:  L R Guterman; S C Standard; A Ahuja; L N Hopkins
Journal:  Curr Opin Neurol       Date:  1993-12       Impact factor: 5.710

5.  Microangiographic Image Guided Localization of a New Asymmetric Stent for Treatment of Cerebral Aneurysms.

Authors:  Ciprian N Ionita; Stephen Rudin; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

6.  Treatment of experimentally induced aneurysms with stents.

Authors:  Timo Krings; Franz J Hans; Walter Möller-Hartmann; Anna Brunn; Ruth Thiex; Thomas Schmitz-Rode; Peter Verken; Kira Scherer; Heiko Dreeskamp; Klaus P Stein; Joachim Gilsbach; Armin Thron
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

7.  Micro-angiography for neuro-vascular imaging. I. Experimental evaluation and feasibility.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann; Iacovos S Kyprianou
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

8.  Endovascular image-guided interventions (EIGIs).

Authors:  Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

9.  Generalized Objective Performance Assessment of a New High-Sensitivity Microangiographic Fluoroscopic (HSMAF) Imaging System.

Authors:  Girijesh K Yadava; Stephen Rudin; Andrew T Kuhls-Gilcrist; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

10.  Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee.

Authors:  Wayne Rosamond; Katherine Flegal; Karen Furie; Alan Go; Kurt Greenlund; Nancy Haase; Susan M Hailpern; Michael Ho; Virginia Howard; Brett Kissela; Bret Kissela; Steven Kittner; Donald Lloyd-Jones; Mary McDermott; James Meigs; Claudia Moy; Graham Nichol; Christopher O'Donnell; Veronique Roger; Paul Sorlie; Julia Steinberger; Thomas Thom; Matt Wilson; Yuling Hong
Journal:  Circulation       Date:  2007-12-17       Impact factor: 29.690

View more
  20 in total

1.  Evaluation of a second-generation self-expanding variable-porosity flow diverter in a rabbit elastase aneurysm model.

Authors:  C N Ionita; S K Natarajan; W Wang; L N Hopkins; E I Levy; A H Siddiqui; D R Bednarek; S Rudin
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

2.  LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System.

Authors:  C Keleshis; Cn Ionita; G Yadava; V Patel; Dr Bednarek; Kr Hoffmann; A Verevkin; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

3.  The Solid-State X-Ray Image Intensifier (SSXII): An EMCCD-Based X-Ray Detector.

Authors:  Andrew Kuhls-Gilcrist; Girijesh Yadava; Vikas Patel; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

4.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

5.  Component Level Modular Design of a Solid State X-ray Image Intensifier for an M×N Array.

Authors:  Ying Huang; Bin Qu; Prateek Sharma; Andrew Kuhls-Gilcrist; Weiyuan Wang; Albert H Titus; Alexander N Cartwright; Daniel R Bednarek; Stephen Rudin
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30

6.  Real-time implementation of distortion corrections for a tiled EMCCD-based Solid State X-ray Image Intensifier (SSXII).

Authors:  C Keleshis; Kr Hoffmann; J Lee; H Hamwi; W Wang; Cn Ionita; Dr Bednarek; A Verevkin; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

7.  Overcoming x-ray tube small focal spot output limitations for high-resolution region of interest imaging.

Authors:  Sandesh K Gupta; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-08

8.  Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF).

Authors:  Ciprian N Ionita; Amit Jain; Brendan Loughran; Swetadri Vasan S N; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-02

9.  Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements.

Authors:  Andrew Kuhls-Gilcrist; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

10.  Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

Authors:  Ciprian N Ionita; Andreea Dohatcu; Andrey Sinelnikov; Jason Sherman; Christos Keleshis; Ann M Paciorek; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.