Literature DB >> 19697692

Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare.

Youngzoon Yoon1, Jung H Cho, Gilwon Yoon.   

Abstract

Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure (BP) was estimated from pulse transit time (PTT) and PPG waveform. PTT is a time interval between an R-wave of electrocardiography (ECG) and a photoplethysmography (PPG) signal. This method does not require an aircuff and only a minimal inconvenience of attaching electrodes and LED/photo detector sensors on a subject. PTT computed between the ECG R-wave and the maximum first derivative PPG was strongly correlated with systolic blood pressure (SBP) (R = -0.712) compared with other PTT values, and the diastolic time proved to be appropriate for estimation diastolic blood pressure (DBP) (R = -0.764). The percent errors of SBP using the individual regression line (4-11%) were lower than those using the regression line obtained from all five subjects (9-14%). On the other hand, the DBP estimation did not show much difference between the individual regression (4-10%) and total regression line (6-10%). Our developed device had a total size of 7 x 13.5 cm and was operated by single 3-V battery. Biosignals can be measured for 72 h continuously without external interruptions. Through a serial network communication, an external personal computer can monitor measured waveforms in real time. Our proposed method can be used for non-constrained, thus continuous BP monitoring for the purpose of personal healthcare.

Mesh:

Year:  2009        PMID: 19697692     DOI: 10.1007/s10916-008-9186-0

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  15 in total

1.  Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes.

Authors:  J Allen; A Murray
Journal:  J Hum Hypertens       Date:  2002-10       Impact factor: 3.012

2.  Development of a compact home health monitor for telemedicine.

Authors:  Gilwon Yoon; Jong Yeon Lee; Kye Jin Jeon; Kun Kook Park; Hong Sig Kim
Journal:  Telemed J E Health       Date:  2005-12       Impact factor: 3.536

3.  [Continuous blood pressure monitoring during stress ECG].

Authors:  D Barschdorff; M Erig
Journal:  Biomed Tech (Berl)       Date:  1998-03       Impact factor: 1.411

4.  Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography.

Authors:  J R Jago; A Murray
Journal:  Clin Phys Physiol Meas       Date:  1988-11

5.  The covariation of blood pressure and pulse transit time in hypertensive patients.

Authors:  R A Allen; J A Schneider; D M Davidson; M A Winchester; C B Taylor
Journal:  Psychophysiology       Date:  1981-05       Impact factor: 4.016

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 7.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

8.  Prospective assessment of an artificial neural network for the detection of peripheral vascular disease from lower limb pulse waveforms.

Authors:  J Allen; A Murray
Journal:  Physiol Meas       Date:  1995-02       Impact factor: 2.833

9.  Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children.

Authors:  C F Wippermann; D Schranz; R G Huth
Journal:  J Clin Monit       Date:  1995-09

10.  Can pulse oximetry be used to measure systolic blood pressure?

Authors:  R Chawla; V Kumarvel; K K Girdhar; A K Sethi; A Indrayan; A Bhattacharya
Journal:  Anesth Analg       Date:  1992-02       Impact factor: 5.108

View more
  21 in total

1.  Accurate Fiducial Point Detection Using Haar Wavelet for Beat-by-Beat Blood Pressure Estimation.

Authors:  Muskan Singla; Syed Azeemuddin; Prasad Sistla
Journal:  IEEE J Transl Eng Health Med       Date:  2020-06-05       Impact factor: 3.316

2.  Development of a telecare system based on ZigBee mesh network for monitoring blood pressure of patients with hemodialysis in health care centers.

Authors:  Yi-Chun Du; You-Yun Lee; Yun-Yuan Lu; Chia-Hung Lin; Ming-Jei Wu; Chung-Lin Chen; Tainsong Chen
Journal:  J Med Syst       Date:  2010-06-03       Impact factor: 4.460

3.  ECG/PPG integer signal processing for a ubiquitous health monitoring system.

Authors:  Woosik Shin; Yong Dae Cha; Gilwon Yoon
Journal:  J Med Syst       Date:  2009-05-13       Impact factor: 4.460

Review 4.  A comprehensive survey of wearable and wireless ECG monitoring systems for older adults.

Authors:  Mirza Mansoor Baig; Hamid Gholamhosseini; Martin J Connolly
Journal:  Med Biol Eng Comput       Date:  2013-01-19       Impact factor: 2.602

5.  Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring.

Authors:  Chang-Sei Kim; Andrew M Carek; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-02       Impact factor: 4.538

6.  Adaptive network-based fuzzy inference system for assessment of lower limb peripheral vascular occlusive disease.

Authors:  Yi-Chun Du; Chia-Hung Lin
Journal:  J Med Syst       Date:  2010-04-13       Impact factor: 4.460

7.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

8.  Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera.

Authors:  In Cheol Jeong; Joseph Finkelstein
Journal:  J Med Syst       Date:  2016-01-20       Impact factor: 4.460

9.  Analysis of heart rate variability during auditory stimulation periods in patients with schizophrenia.

Authors:  Saime Akdemir Akar; Sadık Kara; Fatma Latifoğlu; Vedat Bilgiç
Journal:  J Clin Monit Comput       Date:  2014-05-16       Impact factor: 2.502

10.  Cuffless Blood Pressure Measurement Using a Smartphone-Case Based ECG Monitor with Photoplethysmography in Hypertensive Patients.

Authors:  Zhanna Sagirova; Natalia Kuznetsova; Nana Gogiberidze; Daria Gognieva; Aleksandr Suvorov; Petr Chomakhidze; Stefano Omboni; Hugo Saner; Philippe Kopylov
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.