Literature DB >> 1731537

Can pulse oximetry be used to measure systolic blood pressure?

R Chawla1, V Kumarvel, K K Girdhar, A K Sethi, A Indrayan, A Bhattacharya.   

Abstract

This study evaluates the use of pulse oximetry to accurately monitor systolic arterial blood pressure in 100 healthy volunteers. Determination of arterial blood pressure using oximetry was made at the disappearance of visual display upon blood pressure cuff inflation, at the reappearance of visual display upon cuff deflation, and by averaging the two. The blood pressures obtained by pulse oximetry were compared with the arterial blood pressures obtained by Korotokoff sounds and noninvasive blood pressure equipment. Good agreement was obtained when the average of oximetry-based systolic blood pressure estimates at the disappearance and reappearance of the waveform were compared with Korotokoff sound pressures and noninvasive equipment pressures. Thus pulse oximetry can be used to measure systolic arterial blood pressure. This technique is specifically important for patients with Takayasu's syndrome (pulseless disease) where conventional techniques often fail to monitor systolic arterial blood pressure.

Entities:  

Mesh:

Year:  1992        PMID: 1731537     DOI: 10.1213/00000539-199202000-00004

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  7 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

2.  Non-invasive measurement of systolic blood pressure on the arm utilising photoplethysmography: development of the methodology.

Authors:  C Laurent; B Jönsson; M Vegfors; L G Lindberg
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

3.  Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare.

Authors:  Youngzoon Yoon; Jung H Cho; Gilwon Yoon
Journal:  J Med Syst       Date:  2009-08       Impact factor: 4.460

4.  Anesthesia and Takayasu's arteritis.

Authors:  Natan Weksler
Journal:  J Anesth       Date:  1995-09       Impact factor: 2.078

5.  A comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows.

Authors:  N A Caulkett; T Duke; J V Bailey
Journal:  Can J Vet Res       Date:  1994-04       Impact factor: 1.310

6.  Use of pulse oximetry for blood pressure measurement after cardiac surgery.

Authors:  A J Movius; S L Bratton; G K Sorensen
Journal:  Arch Dis Child       Date:  1998-05       Impact factor: 3.791

7.  Pulse oximetry vs non-invasive blood pressure/oscillometry to record blood pressure in neonates: A prospective observational study.

Authors:  Reenu Raju; Mathai Isac
Journal:  J Family Med Prim Care       Date:  2022-06-30
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.