Literature DB >> 26791993

Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera.

In Cheol Jeong1, Joseph Finkelstein2.   

Abstract

Recent studies demonstrated that blood pressure (BP) can be estimated using pulse transit time (PTT). For PTT calculation, photoplethysmogram (PPG) is usually used to detect a time lag in pulse wave propagation which is correlated with BP. Until now, PTT and PPG were registered using a set of body-worn sensors. In this study a new methodology is introduced allowing contactless registration of PTT and PPG using high speed camera resulting in corresponding image-based PTT (iPTT) and image-based PPG (iPPG) generation. The iPTT value can be potentially utilized for blood pressure estimation however extent of correlation between iPTT and BP is unknown. The goal of this preliminary feasibility study was to introduce the methodology for contactless generation of iPPG and iPTT and to make initial estimation of the extent of correlation between iPTT and BP "in vivo." A short cycling exercise was used to generate BP changes in healthy adult volunteers in three consecutive visits. BP was measured by a verified BP monitor simultaneously with iPTT registration at three exercise points: rest, exercise peak, and recovery. iPPG was simultaneously registered at two body locations during the exercise using high speed camera at 420 frames per second. iPTT was calculated as a time lag between pulse waves obtained as two iPPG's registered from simultaneous recoding of head and palm areas. The average inter-person correlation between PTT and iPTT was 0.85 ± 0.08. The range of inter-person correlations between PTT and iPTT was from 0.70 to 0.95 (p < 0.05). The average inter-person coefficient of correlation between SBP and iPTT was -0.80 ± 0.12. The range of correlations between systolic BP and iPTT was from 0.632 to 0.960 with p < 0.05 for most of the participants. Preliminary data indicated that a high speed camera can be potentially utilized for unobtrusive contactless monitoring of abrupt blood pressure changes in a variety of settings. The initial prototype system was able to successfully generate approximation of pulse transit time and showed high intra-individual correlation between iPTT and BP. Further investigation of the proposed approach is warranted.

Entities:  

Keywords:  Blood pressure; Non-contact monitoring; Pulse transit time; Video

Mesh:

Year:  2016        PMID: 26791993     DOI: 10.1007/s10916-016-0439-z

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  45 in total

1.  Development of a telecare system based on ZigBee mesh network for monitoring blood pressure of patients with hemodialysis in health care centers.

Authors:  Yi-Chun Du; You-Yun Lee; Yun-Yuan Lu; Chia-Hung Lin; Ming-Jei Wu; Chung-Lin Chen; Tainsong Chen
Journal:  J Med Syst       Date:  2010-06-03       Impact factor: 4.460

2.  Advancements in noncontact, multiparameter physiological measurements using a webcam.

Authors:  Ming-Zher Poh; Daniel J McDuff; Rosalind W Picard
Journal:  IEEE Trans Biomed Eng       Date:  2010-10-14       Impact factor: 4.538

3.  Remotely controlled cycling exercise system for home-based telerehabilitation.

Authors:  Joseph Finkelstein; In cheol Jeong
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

Review 4.  A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time.

Authors:  Dilpreet Buxi; Jean-Michel Redouté; Mehmet Rasit Yuce
Journal:  Physiol Meas       Date:  2015-02-19       Impact factor: 2.833

5.  Pulse transit time and blood pressure: an intensive analysis.

Authors:  J D Lane; L Greenstadt; D Shapiro; E Rubinstein
Journal:  Psychophysiology       Date:  1983-01       Impact factor: 4.016

Review 6.  Home blood pressure monitoring: primary role in hypertension management.

Authors:  George S Stergiou; Anastasios Kollias; Marilena Zeniodi; Nikos Karpettas; Angeliki Ntineri
Journal:  Curr Hypertens Rep       Date:  2014-08       Impact factor: 5.369

7.  Physiological parameter monitoring from optical recordings with a mobile phone.

Authors:  Christopher G Scully; Jinseok Lee; Joseph Meyer; Alexander M Gorbach; Domhnull Granquist-Fraser; Yitzhak Mendelson; Ki H Chon
Journal:  IEEE Trans Biomed Eng       Date:  2011-07-29       Impact factor: 4.538

8.  Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

Authors:  Thomas G Pickering; John E Hall; Lawrence J Appel; Bonita E Falkner; John Graves; Martha N Hill; Daniel W Jones; Theodore Kurtz; Sheldon G Sheps; Edward J Roccella
Journal:  Circulation       Date:  2005-02-08       Impact factor: 29.690

Review 9.  Automated office blood pressure measurement in primary care.

Authors:  Martin G Myers; Janusz Kaczorowski; Martin Dawes; Marshall Godwin
Journal:  Can Fam Physician       Date:  2014-02       Impact factor: 3.275

10.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

View more
  9 in total

1.  Cuffless Blood Pressure Monitoring: Promises and Challenges.

Authors:  Jay A Pandit; Enrique Lores; Daniel Batlle
Journal:  Clin J Am Soc Nephrol       Date:  2020-07-17       Impact factor: 8.237

2.  Machine learning approaches to personalize early prediction of asthma exacerbations.

Authors:  Joseph Finkelstein; In Cheol Jeong
Journal:  Ann N Y Acad Sci       Date:  2016-09-14       Impact factor: 5.691

3.  Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension.

Authors:  Yali Zheng; Carmen C Y Poon; Bryan P Yan; James Y W Lau
Journal:  J Med Syst       Date:  2016-07-22       Impact factor: 4.460

4.  A wavelet-based decomposition method for a robust extraction of pulse rate from video recordings.

Authors:  Miha Finžgar; Primož Podržaj
Journal:  PeerJ       Date:  2018-11-27       Impact factor: 2.984

Review 5.  A Broader Look: Camera-Based Vital Sign Estimation across the Spectrum.

Authors:  Christoph Hoog Antink; Simon Lyra; Michael Paul; Xinchi Yu; Steffen Leonhardt
Journal:  Yearb Med Inform       Date:  2019-08-16

6.  An Optimization Study of Estimating Blood Pressure Models Based on Pulse Arrival Time for Continuous Monitoring.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Yang Liu; Hongliu Yu
Journal:  J Healthc Eng       Date:  2020-02-10       Impact factor: 2.682

Review 7.  A review of wearable and unobtrusive sensing technologies for chronic disease management.

Authors:  Yao Guo; Xiangyu Liu; Shun Peng; Xinyu Jiang; Ke Xu; Chen Chen; Zeyu Wang; Chenyun Dai; Wei Chen
Journal:  Comput Biol Med       Date:  2020-12-13       Impact factor: 4.589

8.  Hybrid Optical Unobtrusive Blood Pressure Measurements.

Authors:  Guangfei Zhang; Caifeng Shan; Ihor Kirenko; Xi Long; Ronald M Aarts
Journal:  Sensors (Basel)       Date:  2017-07-01       Impact factor: 3.576

9.  A Revised Point-to-Point Calibration Approach with Adaptive Errors Correction to Weaken Initial Sensitivity of Cuff-Less Blood Pressure Estimation.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Hongliu Yu
Journal:  Sensors (Basel)       Date:  2020-04-13       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.